ASTM D7013 D7013M-2011 red 6522 Standard Guide for Calibration Facility Setup for Nuclear Surface Gauges《核表面量规校准设施装配的标准指南》.pdf
《ASTM D7013 D7013M-2011 red 6522 Standard Guide for Calibration Facility Setup for Nuclear Surface Gauges《核表面量规校准设施装配的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7013 D7013M-2011 red 6522 Standard Guide for Calibration Facility Setup for Nuclear Surface Gauges《核表面量规校准设施装配的标准指南》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:D7013041Designation: D7013/D7013M 11Standard Guide forNuclear Surface Moisture and Density Gauge CalibrationFacility SetupCalibration Facility Setup for Nuclear SurfaceGauges1This standard is issued under the fixed designation D7013/D7013M; the number immediately following the designatio
2、n indicates theyear of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval. 1NOTEReferences to ASTMstandards in Section 6.1
3、 were editorially updated in March 2010.1. Scope1.1This guide outlines procedures for setup of nuclear moisture density gauge in shielded, Method A, and unshielded, MethodB, configurations.1.1 This guide outlines procedures for setup of a nuclear gauge calibration facility in either a shielded bay o
4、r an unshieldedareaGuide A and Guide B, respectively.1.2 This guide does not attempt to describe the calibration techniques or methods. It is assumed that this guide will be used bypersons familiar with the operations of the gauge and in performing proper calibration, service and maintenance.1.3 Thi
5、s guide does not attempt to address maintenance or service procedures related to the gauge.1.4This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of theuser of this guide to establish appropriate safety, and health practices an
6、d determine the applicability of regulatory limitationsprior to use.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. C
7、ombining values from thetwo systems may result in non-conformance with the standard.1.5 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility ofthe user of this guide to establish appropriate safety, and health practices and dete
8、rmine the applicability of regulatory limitationsprior to use.1.6 This guide offers an organized collection of information or a series of options and does not recommend a specific courseof action. This document cannot replace education or experience and should be used in conjunction with professiona
9、l judgment.Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replacethe standard of care by which the adequacy of a given professional service must be judged, nor should this document be appliedwithout consideration of a projects
10、 many unique aspects. The word “Standard” in the title of this document has been approvedthrough ASTM consensus process.1.61.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in practiceD6026.1.6.11.7.1 The method used to specify how
11、 data are collected, calculated, or recorded in this standard is not directly related to theaccuracy to which the data can be applied in the design or other uses, or both. How one applies the results obtained using thisstandard is beyond its scope.2. Referenced Documents2.1 ASTM Standards:2D653 Term
12、inology Relating to Soil, Rock, and Contained Fluids1This guide is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.08 on Special and ConstructionControl Tests.Current edition approved Dec. 1, 2004. Published December 2004. DOI: 10.15
13、20/D7013-04e1.Current edition approved Feb. 15, 2011. Published March 2011. Originally approved in 2004. Last previous edition approved in 2004 as D7013041. DOI:10.1520/D7013_D7013M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceas
14、tm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Beca
15、useit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 B
16、arr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used inEngineering Design and ConstructionD6026 Practice for Using Significant Digits in Geotechnical DataD6938
17、 Test Method for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth)3. Terminology3.1For common definitions of terms refer to Terminology3.1 For definitions of common technical terms in this standard, refer to Terminology D653.3.2 Definitions of Terms Spe
18、cific to This Standard:3.2.1 Unshielded Calibration bayAn open area within a calibration facility where the closest wall is a minimum of 1 meter(3 ft.) from the spot in which the gauge is being calibrated. cinder blocka hollow building block made with concrete and coalcinders.3.2.2 Shielded Calibrat
19、ion bayAn enclosed area surrounded by concrete blocks or walls to protect the gauge being calibratedfrom outside influence and background radiation from all gauges in the facility. high density concrete blockssolid concreteblocks designed for areas requiring radiation shielding.3.2.3 Shielded Storag
20、e BayAn enclosed area shielded by walls to maintain and control radiation background in the facilityand to reduce influences from stored gauges. safe positionposition of the density source during the standardization process ofthe gauge.3.2.4 shielded calibration bayan enclosed area surrounded by wal
21、ls in order to reduce background radiation to an acceptablelevel.3.2.5 shielded storage bayan enclosed area with sufficient shielding material to maintain and control radiation background inthe facility and to reduce influences from stored gauges.3.2.6 unshielded areaan open area within a calibratio
22、n facility where the closest wall is a minimum of 1 m 3 ft from thespot in which the gauge is being calibrated.4. Summary of Method4.1Nuclear moisture density gauges require proper calibration to ensure measurement repeatability between gauges. Since thesegauges contain radioactive isotopes, influen
23、ces from the surroundings and other gauges should be controlled during the calibrationprocess. This guide provides procedures to facilities involved in calibration of one or more gauges in shielded and unshieldedcalibration bays. The goal of this guide is to insure proper gauge calibration and to re
24、duce influences that would result in fieldmeasurement variability between gauges.4.1 Nuclear moisture density gauges require proper calibration. Since these gauges contain radioactive isotopes, influences fromthe surroundings and other gauges should be controlled during the calibration process. This
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7013D7013M2011RED6522STANDARDGUIDEFORCALIBRATIONFACILITYSETUPFORNUCLEARSURFACEGAUGES 表面 量规 校准 设施

链接地址:http://www.mydoc123.com/p-524248.html