ASTM D6979-2013 red 2507 Standard Test Method for Polyurethane Raw Materials Determination of Basicity in Polyols Expressed as Percent Nitrogen《聚氨酯原材料的标准试验方法 多元醇碱度的测定(以氮百分比表示)》.pdf
《ASTM D6979-2013 red 2507 Standard Test Method for Polyurethane Raw Materials Determination of Basicity in Polyols Expressed as Percent Nitrogen《聚氨酯原材料的标准试验方法 多元醇碱度的测定(以氮百分比表示)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6979-2013 red 2507 Standard Test Method for Polyurethane Raw Materials Determination of Basicity in Polyols Expressed as Percent Nitrogen《聚氨酯原材料的标准试验方法 多元醇碱度的测定(以氮百分比表示)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6979 08D6979 13Standard Test Method forPolyurethane Raw Materials: Determination of Basicity inPolyols, Expressed as Percent Nitrogen1This standard is issued under the fixed designation D6979; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the basic constituents in polyols that are soluble in gl
3、acial acetic acid and reactive with perchloricacid. Samples containing 0.3 10 % nitrogen have been evaluated by this method. This test method is applicable to polyetherpolyols and polyether polyol blends that are used in urethane reactions. (See Note 1.)1.2 The values stated in SI units are to be re
4、garded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and det
5、ermine the applicability of regulatorylimitations prior to use.NOTE 1This standard is equivalent to ISO 25761:082. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsE180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Speci
6、alty Chemicals(Withdrawn 2009)3E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsFor definitions of terms used in this test method see Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 percent nitroge
7、nthe quantity of perchloric acid-titratable base, expressed as a weight percentage of nitrogen in a sample.4. Summary of Test Method4.1 The sample is dissolved in glacial acetic acid. The resulting single-phase solution is titrated at room temperature to apotentiometric end point with a standardized
8、 solution of perchloric acid in acetic acid. Results are reported as percent nitrogen.5. Significance and Use5.1 This test method is suitable for quality control, as a specification test, and for research. The results are measures ofbatch-to-batch uniformity and may be are useful in estimating react
9、ivity.5.1.1 The percent nitrogen can be used to characterize a polyol or indicate amounts of certain components in a polyol blend.5.1.2 It is permissible to also express the results in equivalents of base per gram of sample, if desired.6. Apparatus6.1 Potentiometric Automatic Titrator6.2 Autotitrato
10、r Buret with Dosing Device, 20-mL1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.22 on Cellular Materials - Plasticsand Elastomers.Current edition approved Aug. 1, 2008Nov. 1, 2013. Published September 2008November 2
11、013. Originally approved in 2003. Last previous edition approved in 20032008as D6979 - 03.D6979 - 08. DOI: 10.1520/D6979-08.10.1520/D6979-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. ForAnnual Book ofASTM Standardsvolume
12、information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have be
13、en made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official documen
14、t.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.3 pH Glass Electrode and Reference Electrode or a Combination Glass Electrode6.4 Analytical Balances, capable of weighing to the nearest 0.01g and 0.0001 g6.5 Magnetic Stirrer/Hotpla
15、te7. Reagents and Materials7.1 Purity of ReagentsUse reagent-grade chemicals in all tests. Unless otherwise indicated, it is intended that all reagentsconform to the specifications of the Committee on Analytical Reagents of the American Chemical Society where suchspecifications are available.4 It is
16、 permissible to use other grades provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy of the determination.7.2 Acetic Acid, Glacial7.3 Acetic Anhydride7.4 Perchloric Acid, (70 % nominal)7.5 Perchloric acid in Acetic Acid (0.
17、10 N)Prepare 0.10 N perchloric acid in acetic acid. For example, in a 1000-mLvolumetric flask dissolve 8.7 mL of perchloric acid in 500 mL of glacial acetic acid; add 25 mL of acetic anhydride and dilute tovolume with glacial acetic acid.NOTE 2Perchloric Acidis extremely irritating to the skin, eyes
18、 and mucous membrane; highly toxic via oral and inhalation routes; and can formexplosive mixtures when mixed with carbonaceous material or allowed to dry. Concentrated material shall only be used in a hood approved for perchloricacid use. Skin contactwash with soap and water. Eye contactflush with c
19、opious amounts of water for 15 minutes. Inhalation - move victim to anuncontaminated area. Ingestiondo not induce vomiting. For all exposures seek professional medical advice.8. Procedure8.1 Weigh the appropriate amount of sample, W into a suitable container. Calculate the target weight of sample to
20、 be analyzedas follows:W52/P (1)where:W = the target weight of the sample to be analyzed in grams, andP = the expected percent nitrogen content of the sample.NOTE 3For sample weights below 10.0 g, record the weight to the nearest 0.1 mg; for sample weights greater than 10.0 g, record the weight to t
21、henearest 0.01g.8.2 Add 100 mL of glacial acetic acid and gently stir until the sample dissolves completely.NOTE 4If necessary, the mixture can be heated gently until the sample is completely dissolved.8.3 Titrate the sample solution potentiometrically with 0.10 N perchloric acid through the end poi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD69792013RED2507STANDARDTESTMETHODFORPOLYURETHANERAWMATERIALSDETERMINATIONOFBASICITYINPOLYOLSEXPRESSEDASPERCENTNITROGEN

链接地址:http://www.mydoc123.com/p-524142.html