《ASTM D6606-2000(2017) 6938 Standard Test Method for Viscosity and Yield of Vehicles and Varnishes by the Duke Viscometer《用DUCK粘度计测定调色剂和清漆粘度和屈服点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6606-2000(2017) 6938 Standard Test Method for Viscosity and Yield of Vehicles and Varnishes by the Duke Viscometer《用DUCK粘度计测定调色剂和清漆粘度和屈服点的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6606 00 (Reapproved 2017)Standard Test Method forViscosity and Yield of Vehicles and Varnishes by the DukeViscometer1This standard is issued under the fixed designation D6606; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the procedure for determiningthe viscosity of varnishes, ink vehicles, and
3、similar liquids thatare essentially nonvolatile and unreactive under ordinary roomconditions using the DukeAutomated high-shear rod and collarviscometer.21.2 The instrument in this test method is similar in principleto the falling-rod viscometer described in Test Method D4040except that the collar i
4、s motor driven and the range of availableshear stresses is considerably greater. This instrument iscapable of measured and extrapolated viscosity and yieldvalues provided the proper model is chosen for the givenapplication. See Section 6 for the ranges of specified models.1.3 The values stated in SI
5、 units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, that may be associated with its use. Itis the responsibility of the user of this standard to establish anyappropriate safe
6、ty and health practices and determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D4040 Test Method for Rheological Properties of PastePrinting and Vehicles by the Falling-Rod Viscometer3. Terminology3.1 DefinitionsTerms relative to this test me
7、thod aredefined in Test Method D4040 except for those found in 3.2.3.2 Definitions of Terms Specific to This Standard:3.2.1 yield value, nThe Lehmans yield value that isdefined as the stress at 2.5 s1.3.2.1.1 DiscussionThis value can be either extrapolated ormeasured.3.2.2 shortness ratio, na ratio
8、to determine the shortnesscharacteristic of the fluid where SR = yield value/apparentviscosity.4. Summary of Test Method4.1 This automated test method is based upon accuratemeasurement of the force that is transferred at a knowntemperature into a stationary vertical rod as a fluid such asprinting in
9、k/varnish moves through a precision measurementgap formed between the outside diameter of the rod and theinside diameter of collar of specific geometry as said collarmoves upward along the length of the rod at specifiedvelocities.4.2 The operator of the instrument and the customer mustagree on the p
10、reprogrammed test sequence, which is to be runfor a given material and the desired test temperature. Supervi-sory personnel should know the specifics of each prepro-grammed test sequence, how to change a given test sequence,and how to make a new test sequence.4.3 This test method provides actual mea
11、sured test data offluids at specified shear rates, which can be programmed torelate. In addition to actual measured data, extrapolated datausing the “power law mathematical model” is provided thatcorrelates with manual testing methods as outlined in TestMethod D4040.4.4 Specified test reference temp
12、eratures can range from 20to 40C. Allowable deviation from desired test referencetemperature could be specified differently in each test se-quence.Allowable programmable is within the range of 0.05 to0.4C.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,
13、 Materials, andApplications and is the direct responsibility ofSubcommittee D01.37 on Ink Vehicles.Current edition approved Feb. 1, 2017. Published February 2017. Originallyapproved in 2000. Last previous edition approved in 2010 as D6606 00 (2010).DOI: 10.1520/D6606-00R17.2The sole source of supply
14、 of an automated high shear rod and collar viscometerknown to the committee at this time is Duke Custom Systems, Inc., Pleasant View,TN. If you are aware of alternative suppliers, please provide this information toASTM International Headquarters. Your comments will receive careful consider-ation at
15、a meeting of the responsible technical committee,1which you may attend.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AST
16、M website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopmen
17、t of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15. Significance and Use5.1 Actual direct measurements of apparent viscosity andstress at shear rates of interest can be useful in the practicalcontrol of ink v
18、iscosity during production and the specificationacceptance between supplier and purchaser.5.2 Use of the Duke automated viscometer provides directmeasurements for viscosity and yield value versus extrapolat-ing data points that may be far from the desired shear rates.6. Apparatus6.1 Table 1 describe
19、s each model of the Duke automatedhigh shear rod and collar viscometer with the appropriateranges for the ink or varnish being tested.7. Materials7.1 ASTM Standard Viscosity Fluids(For calibration pur-poses only.) At approximately 100, 200, and 400 poise, spanthe practical range of the instrument wi
20、thout inducing self-heating errors. The required fluids4are N4000 (100 poise at25C), S8000 (200 poise at 25C), and N15000 (400 poise at25C).7.2 Lint and Metal-Free Rags or Tissues of appropriate size,so that they may be pulled or pushed completely through thecollar in a single pass.7.3 Naphtha or ot
21、her Low-Boiling Solvent in a wash bottleor closed metal container.8. Hazards8.1 Warning: Solvents may be hazardous to the skin andeyes. In addition to other precautions, always wear protectivegloves and safety glasses during cleanup to avoid solventcontact with skin and eyes. See suppliers material
22、safety datasheet for further information on each solvent used.8.2 Instrument Warning: Never operate the instrumentwith the rod installed without fluid in the collar.9. Preparation of Apparatus9.1 Set the viscometer up on a sturdy vibration-free benchcapable of supporting at least 6.75 sq. m.9.2 Loca
23、te the viscometer in an area free of direct sunlightto prevent sun-induced heating inside the clear temperature-controlled enclosure.9.3 Level the viscometer by turning the adjustable feet up ordown until the spirit level is centered and the instrument is freefrom wobble.9.4 Clean the rod and collar
24、 thoroughly with tissues wettedwith naphtha or other appropriate solvent. Remove residualsolvent with clean dry tissue. Ensure rod and collar are free oflint or other particles from tissue or environment. Warning:Failure to clean instrument adequately will severely influenceresults.9.5 Ensure identi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6606200020176938STANDARDTESTMETHODFORVISCOSITYANDYIELDOFVEHICLESANDVARNISHESBYTHEDUKEVISCOMETER

链接地址:http://www.mydoc123.com/p-523027.html