ASTM D6547-2000(2010) 5625 Standard Test Method for Corrosiveness of Lubricating Fluid to Bimetallic Couple《双金属电偶用润滑液防腐性能的标准试验方法》.pdf
《ASTM D6547-2000(2010) 5625 Standard Test Method for Corrosiveness of Lubricating Fluid to Bimetallic Couple《双金属电偶用润滑液防腐性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6547-2000(2010) 5625 Standard Test Method for Corrosiveness of Lubricating Fluid to Bimetallic Couple《双金属电偶用润滑液防腐性能的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6547 00 (Reapproved 2010)Standard Test Method forCorrosiveness of Lubricating Fluid to Bimetallic Couple1This standard is issued under the fixed designation D6547; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the corrosiveness of hydraulicand lubricating fluids to a bimetallic galvanic couple.NO
3、TE 1This test method replicates Fed-Std No. 791, Method 5322.2.It utilizes the same apparatus, test conditions, and evaluation criteria, butit describes test procedures more explicitly.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informatio
4、nonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refere
5、nced Documents2.1 ASTM Standards:2A322 Specification for Steel Bars, Alloy, Standard Grades2.2 Federal Standards:Fed-Std No. 791, Method 5322.2 Corrosiveness of Oil on aBimetallic Couple33. Summary of Test Method3.1 This test method consists of fitting a brass clip to thefluid-coated surface of a st
6、eel disk, storing the assembly atapproximately 50 % relative humidity for ten days, and visu-ally inspecting the assembly for evidence of galvanic corro-sion.4. Significance and Use4.1 Corrosiveness of a fluid to a bimetallic couple is one ofthe properties used to evaluate hydraulic or lubricating f
7、luids.It is an indicator of the compatibility of a fluid with a brass onsteel galvanic couple at ambient temperature and 50 % relativehumidity.5. Apparatus5.1 Desiccating Jars, two.5.2 Magnifier,103 power.5.3 Glass Stirring Rod.5.4 Abrasive Papers, silicon-carbide or aluminum oxide(150, 240, 400, 60
8、0 grit, one sheet per disk).5.5 Cloth, lint-free, clean, dry.5.6 Chromium Alloy Steel Disks, three for each test sample.45.7 Brass Clips, three for each test sample.46. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is in
9、tended thatall reagents conform to the Committee on Analytical Reagentsof the American Chemical Society where such specificationsare available.56.2 Etching Solution, consisting of distilled water, 450 mL;nitric acid, concentrated, 225 mL; sulfuric acid, concentrated,300 mL; and hydrochloric acid, co
10、ncentrated, 8 mL.6.2.1 To avoid hazardous reactions when preparing theetching solution, place the distilled water (450 mL) in a 1.5-L,or larger, glass beaker set in a container of ice and water. Stirwith a glass mechanical stirrer or plastic coated magnetic spinbar while slowly adding concentrated s
11、ulfuric acid (300 mL).Add more ice to the cooling bath as needed. When acidaddition is complete, continue stirring until the solution hascooled to room temperature, and then start slow addition of theconcentrated nitric acid (225 mL). Continue stirring after acidaddition until the solution has coole
12、d to room temperature, and1This test method is under the jurisdiction of ASTM CommitteeD02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.N0.02 on Industrial Applications.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 20
13、00. Last previous edition approved in 2005 as D654700(2005).DOI: 10.1520/D6547-00R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
14、page onthe ASTM website.3Available from Standardization Documents Order Desk, Building 4 Section D,700 Robbins Avenue, Philadelphia, PA 191115904, Attn: NPODS.4The sole source of supply of the apparatus known to the committee at this timeis Metaspec, 790 W. Mayfield Rd., San Antonio, TX 78211. If yo
15、u are aware ofalternative suppliers, please provide this information to ASTM InternationalHeadquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee,1which you may attend.5Reagent Chemicals, American Chemical Society Specifications, AmericanChem
16、ical Society, Washington, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rock
17、ville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.then add concentrated hydrochloric acid (8 mL). Allow themixture to equilibrate to room temperature before use.(WarningNitric, hydrochloric, and sulfuric acids are verycorrosiv
18、e. Nitric acid and sulfuric acid are also oxidizing acids.The analyst should prepare the etching solution in a well-ventilated hood and wear appropriate gloves, apron, and faceshield.)6.3 Acetone, technical grade. (WarningFlammable.Health hazard.)6.4 Distilled Water.NOTE 2Both distilled and deionize
19、d water were used in the roundrobin with no apparent impact on test outcome.6.5 Saturated Aqueous Solution, in contact with excesscalcium nitrate tetrahydrate.NOTE 3A saturated aqueous solution in contact with an excess ofCa(NO3)24H2O will produce 51 % relative humidity within a closedspace at 25C.
20、To prepare the saturated solution, dissolve 660 g ofCa(NO3)24H2O in 100 cc of water at 30C.66.6 Low-Erucic Rapeseed Oil, commercial grade.77. Test Specimen7.1 Gather reagents and materials before beginning speci-men preparation. The specimens must be prepared and as-sembled for testing on the same d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6547200020105625STANDARDTESTMETHODFORCORROSIVENESSOFLUBRICATINGFLUIDTOBIMETALLICCOUPLE 双金属 电偶用 润滑

链接地址:http://www.mydoc123.com/p-522822.html