ASTM D6501-2009 5000 Standard Test Method for Phosphonate in Brines《海水中磷酸酯的试验方法》.pdf
《ASTM D6501-2009 5000 Standard Test Method for Phosphonate in Brines《海水中磷酸酯的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6501-2009 5000 Standard Test Method for Phosphonate in Brines《海水中磷酸酯的试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6501 09Standard Test Method forPhosphonate in Brines1This standard is issued under the fixed designation D6501; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indica
2、tes the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the colorimetric determinationof phosphonate (PNA) in brines from gas and oil productionoperations in the range from 0.1 to 5 mg/L.1.2 Thi
3、s phosphonate method is intended for use to analyzelow concentration of phosphonate in brine containing interfer-ing elements. This test method is most useful for analyzingphosphonate at 0.1 to 1 mg/L range in brines with interferingelements; however, it requires personnel with good analyticalskill.
4、1.3 This test method has been used successfully withreagent water and both field and synthetic brine. It is the usersresponsibility to ensure the validity of this test method forwaters of untested matrices.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement
5、 are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation
6、s prior to use. For specific hazardstatements, see 9.1.3.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sa
7、mpling Water from Closed ConduitsD3856 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD4375 Practice for Basic Statistics in Committee D19 onWaterD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor St
8、andard Test Methods for Water AnalysisE275 Practice for Describing and Measuring Performanceof Ultraviolet and Visible Spectrophotometers3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1
9、phosphonate, na group of organophosphorus com-pounds typically used for mineral scale and corrosion control,as cleaning agents, dispersants, and chelants.3.2.1.1 DiscussionTypical phosphonate compounds in-clude, but are not limited to, the following phosphonic acid andtheir neutralized salts: Aminot
10、ri(methylenephosphonic acid),1-hydroxyethylidene-1,1-diphosphonic acid, ethylenediamine-tetra (methylenephosphonic acid), hexamethylenediaminetetra(methylenephosphonic acid), and diethylenetriaminepenta(methylenephosphonic acid).4. Summary of Test Method4.1 Phosphonate materials are converted to ort
11、hophosphateby potassium persulfate digestion. The orthophosphate is thenreacted with ammonium molybdate to form a phosphomolyb-date complex. The complex is extracted with a methyl isobutylketone/cyclohexane mixture and measured colorimetrically.5. Significance and Use5.1 This test method is useful f
12、or the determination of tracelevel phosphonate residues in brines. Chemical treatmentwhich contain phosphonates are used as mineral scale andcorrosion inhibitors in gas and oil drilling and productionoperations; and other industrial applications. Often, the deci-sion for treatment is based on the ab
13、ility to measure lowphosphonate concentration and not upon performance criteria.Phosphonate concentrations as low as 0.16 mg/L have been1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.
14、Current edition approved Oct. 1, 2009. Published October 2009. Originallyapproved in 1999. Last previous edition approved in 2004 as D650104. DOI:10.1520/D6501-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
15、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.shown effective i
16、n carbonate scale treatment. This test methodenables the measurement of sub-mg/L phosphonate concentra-tion in brines containing interfering elements.5.2 The procedure includes measuring total (see 12.3.8) andfree orthophosphate (see 12.4.3) ions and the difference inconcentration is the phosphonate
17、 concentration. The samplecould contain orthophosphate naturally, or from decompositionof the phosphonate during processing or well treatment or fromtreating compounds containing molecular dehydrated phos-phates.6. Interferences6.1 Sulfide interferes in this test method, but techniquesdescribed in t
18、he procedure (see 9.1.2) eliminate this interfer-ence. Concentrations less than 1000 mg/L copper (Cu+2) andsilica (SiO2/SiO32/Si+4); and less than 200 mg/L of iron(Fe+2/Fe+3) can be tolerated.6.2 Produced brines can contain high concentrations ofdissolved solids. Some of these dissolved solids tend
19、toprecipitate when produced brines reach new equilibria atatmospheric temperature and pressure. Phosphonate will co-precipitate or adsorb onto these newly formed solids andbecome unavailable for analysis. This problem can be mini-mized by acidifying the brine sample on-site with hydrochloricacid to
20、pH below 2.6.3 Glassware must be cleaned with phosphate free deter-gent and rinsed with 0.1 N hydrochloric acid to remove allresidual phosphate or phosphonate.6.4 The standard addition method in 12.6 is recommendedfor brine with high matrix interference.7. Apparatus7.1 Pressure Cooker or Sterilizer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD650120095000STANDARDTESTMETHODFORPHOSPHONATEINBRINES 海水 磷酸酯 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-522692.html