ASTM D6493-2011 8125 Standard Test Methods for Softening Point of Hydrocarbon Resins and Rosin Based Resins by Automated Ring-and-Ball Apparatus《用自动环和球装置检测烃类树脂和松香基树脂软化点的标准试验方法》.pdf
《ASTM D6493-2011 8125 Standard Test Methods for Softening Point of Hydrocarbon Resins and Rosin Based Resins by Automated Ring-and-Ball Apparatus《用自动环和球装置检测烃类树脂和松香基树脂软化点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6493-2011 8125 Standard Test Methods for Softening Point of Hydrocarbon Resins and Rosin Based Resins by Automated Ring-and-Ball Apparatus《用自动环和球装置检测烃类树脂和松香基树脂软化点的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6493 11Standard Test Methods forSoftening Point of Hydrocarbon Resins and Rosin BasedResins by Automated Ring-and-Ball Apparatus1This standard is issued under the fixed designation D6493; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods are intended for determining thesoftening point of hydrocarbon resi
3、ns, rosin based resins andsimilar materials by means of an automated ring-and-ballapparatus. Portions are similar in technical content to theautomated-apparatus versions of Test Methods D36, E28, andISO 4625.1.1.1 The ring-and-ball softening point of a hydrocarbonresin and rosin based resins may als
4、o be determined with lowerprecision using the manual ring-and-ball softening point pro-cedure in Test Methods E28.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard method does not purport to address all ofth
5、e safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D36 Test Method for Soften
6、ing Point of Bitumen (Ring-and-Ball Apparatus)E1 Specification for ASTM Liquid-in-Glass ThermometersE28 Test Methods for Softening Point of Resins Derivedfrom Naval Stores by Ring-and-Ball ApparatusE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting
7、an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:ISO 4625 Binders for paints and varnishesDeterminationof softening pointRing-and-ball method33. Summary of Test Method3.1 These test methods are for the determination of thesoftening pointthe temperature at which a d
8、isk of the resinheld within a horizontal ring is forced downward a distance of25.4 mm (1.00 in.) under the weight of a standard steel ball, asthe specimen is heated at 5C/min. in a specified liquid bath.4. Significance and Use4.1 For hydrocarbon resins and rosin based resins, softeningdoes not take
9、place at a definite temperature. As the tempera-ture rises, these materials gradually change from brittle solidsor very viscous liquids to less viscous liquids. For this reason,determination of the softening point must be made by a fixed,arbitrary, and closely defined method if the results obtained
10、areto be comparable.5. Sample Preparation5.1 Preparation of Sample by the Pour Method: Thisprocedure is suitable for resins that can be heated and pouredwithout adverse effect on the softening point.5.1.1 Select a sample representative of the material to betested. The sample should consist of flakes
11、, pastilles, or brokenlumps. Avoid inclusion of finely divided material or dust.5.1.2 Select a quantity of resin having a volume at leasttwice that necessary to fill the desired number of rings, andmelt it in a clean container, using an oven, hot plate, sand bathor oil bath to prevent local overheat
12、ing. If necessary, stirslowly, taking care to avoid incorporating air bubbles in thesample. Melt the sample completely, but do not heat it above atemperature necessary to pour the material readily. The timefrom the beginning of heating to pouring should not exceed 15min.5.1.3 For materials that tend
13、 to crack or shrink in the ring oncooling, immediately before filling the ring, preheat the ring toapproximately the temperature at which the material is to bepoured. The ring, while being filled, should rest bottom down(see Fig. 1(a) on a suitable metal surface. Pour the sample intothe ring so as t
14、o leave an excess on cooling. After cooling a1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.34 on Pine Chemicals and HydrocarbonResins.Current edition approved June 1,
15、 2011. Published June 2011. Originallyapproved in 1999. Last previous edition approved in 2010 as D6493 05 (2010).DOI: 10.1520/D6493-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
16、formation, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 1
17、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.minimum of 30 min., trim off the excess resin from the top andoutside of the ring. To remove excess resin from the top, cut theexcess off cleanly with a heated knife or spatula, or grasp thering in a pair of tongs and
18、 draw the top surface quickly andfirmly over the surface of a heated plate.NOTE 1If the determination is repeated, us a clean container and afresh sample.5.2 Preparation of Sample by the Powder Method: Thisprocedure is suitable for high softening-point materials thatcannot be heated and poured witho
19、ut adverse effects on thesoftening point. See Appendix X1.1, Alternate Sample Prepa-ration Procedures.5.3 Preparation of Samples Having a Low Softening Point(up to 35C (95F):5.3.1 Place a ring on a piece of aluminum foil. Pour thematerial to be tested into the ring, then place the foil and thefilled
20、 ring on dry ice or in a freezer to cool. The material in thering must be free of bubbles.5.3.2 After cooling, cut and scrape off any excess materialusing a slightly heated spatula, then slide the ring gently fromthe foil. Place the ring in the supporting apparatus, and performthe softening point de
21、termination in accordance with Section12.6. Apparatus6.1 Automated Ring-and-Ball Softening Point Instrument,having a test assembly consisting of: a ring holder, a metalplate, and a cover mounted on two support rods (see Fig. 1(b)and (d), a built in digital temperature that should be standard-ized pe
22、riodically to ensure that it meets the specifications forand gives the same readings as thermometers given in Speci-fication E1, a digital temperature display, a heating unit and aheating-rate controller.6.2 RingA brass, shouldered ring conforming to thedimensions shown in Fig. 1(a).6.3 BallA steel
23、ball, 9.53 6 0.1 mm (38 in.) in diameter,weighing between 3.45 and 3.55 g.6.4 Ball-Centering Guide (optional), having the dimensionsgiven in Fig. 1(c).FIG. 1 Shouldered Ring, Ring Holder, Ball-Centering Guide, and Assembly of ApparatusD6493 1126.5 Beaker, 600 mL, borosilicate glass, to hold the bath
24、liquid. ensure that the dimensions will properly fit the heatingunit.6.6 StirrerEither a magnetic stirring motor and a mag-netic stir bar, or a direct-driven agitator with a stirring motor.The dimensions of a stir bar must be such that the bar spinsfreely under the test assembly. The bath must be st
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD649320118125STANDARDTESTMETHODSFORSOFTENINGPOINTOFHYDROCARBONRESINSANDROSINBASEDRESINSBYAUTOMATEDRINGANDBALLAPPARATUS

链接地址:http://www.mydoc123.com/p-522667.html