《ASTM D6493-2005 Standard Test Methods for Softening Point of Hydrocarbon Resins by Automated Ring and Ball Apparatus《用自动环球仪测定烃类树脂软化点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6493-2005 Standard Test Methods for Softening Point of Hydrocarbon Resins by Automated Ring and Ball Apparatus《用自动环球仪测定烃类树脂软化点的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6493 05Standard Test Methods forSoftening Point of Hydrocarbon Resins by Automated Ring-and-Ball Apparatus1This standard is issued under the fixed designation D 6493; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods are intended for determining thesoftening point of hydrocarbon resins and similar mate
3、rials bymeans of an automated ring-and-ball apparatus. Portions aresimilar in technical content to the automated-apparatus ver-sions of Test Methods D 36, E 28, and ISO 4625.1.1.1 The ring-and-ball softening point of a hydrocarbonresin may also be determined with lower precision using themanual ring
4、-and-ball softening point procedure in Test Meth-ods E28.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard method does not purport to address all ofthe safety concerns, if any, associated with its use. It is
5、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D36 Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus)E1 Specifica
6、tion for ASTM Liquid-in-Glass ThermometersE28 Test Methods for Softening Point of Resins Derivedfrom Naval Stores by Ring-and-Ball ApparatusE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a
7、Test Method2.2 ISO Standard:ISO 4625 Binders for paints and varnishesDeterminationof softening pointRing-and-ball method23. Summary of Test Method3.1 These test methods are for the determination of ahydrocarbon resins softening pointthe temperature at whicha disk of the resin held within a horizonta
8、l ring is forceddownward a distance of 25.4 mm (1.00 in.) under the weight ofa standard steel ball, as the specimen is heated at 5C/min. ina specified liquid bath.4. Significance and Use4.1 For hydrocarbon resins, softening does not take place ata definite temperature.As the temperature rises, these
9、 materialsgradually change from brittle solids or very viscous liquids toless viscous liquids. For this reason, determination of thesoftening point must be made by a fixed, arbitrary, and closelydefined method if the results obtained are to be comparable.5. Sample Preparation5.1 Preparation of Sampl
10、e by the Pour Method: Thisprocedure is suitable for resins that can be heated and pouredwithout adverse effect on the softening point.5.1.1 Select a sample representative of the material to betested. The sample should consist of flakes, pastilles, or brokenlumps. Avoid inclusion of finely divided ma
11、terial or dust.5.1.2 Select a quantity of resin having a volume at leasttwice that necessary to fill the desired number of rings, andmelt it in a clean container, using an oven, hot plate, sand bathor oil bath to prevent local overheating. If necessary, stirslowly, taking care to avoid incorporating
12、 air bubbles in thesample. Melt the sample completely, but do not heat it above atemperature necessary to pour the material readily. The timefrom the beginning of heating to pouring should not exceed 15min.5.1.3 For materials that tend to crack or shrink in the ring oncooling, immediately before fil
13、ling the ring, preheat the ring toapproximately the temperature at which the material is to bepoured. The ring, while being filled, should rest bottom down(see Fig. 1(a) on a suitable metal surface. Pour the sample intothe ring so as to leave an excess on cooling. After cooling aminimum of 30 min.,
14、trim off the excess resin from the top andoutside of the ring. To remove excess resin from the top, cut theexcess off cleanly with a heated knife or spatula, or grasp the1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and
15、 are the directresponsibility of Subcommittee D01.38 on Hydrocarbon Resins.Current edition approved July 1, 2005. Published August 2005. Originallyapproved in 1999. Last previous edition approved in 1999 as D 6493 99.2Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Fl
16、oor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ring in a pair of tongs and draw the top surface quickly andfirmly over the surface of a heated
17、 plate.NOTE 1If the determination is repeated, us a clean container and afresh sample.5.2 Preparation of Sample by the Powder Method: Thisprocedure is suitable for high softening-point materials thatcannot be heated and poured without adverse effects on thesoftening point. See Appendix X1.1, Alterna
18、te Sample Prepa-ration Procedures.5.3 Preparation of Samples Having a Low Softening Point(up to 35C (95F):5.3.1 Place a ring on a piece of aluminum foil. Pour thematerial to be tested into the ring, then place the foil and thefilled ring on dry ice or in a freezer to cool. The material in thering mu
19、st be free of bubbles.5.3.2 After cooling, cut and scrape off any excess materialusing a slightly heated spatula, then slide the ring gently fromthe foil. Place the ring in the supporting apparatus, and performthe softening point determination in accordance with Section12.6. Apparatus6.1 Automated R
20、ing-and-Ball Softening Point Instrument,having a test assembly consisting of: a ring holder, a metalplate, and a cover mounted on two support rods (see Fig. 1(b)and (d), a temperature-measuring device (in accordance withSpecification E1), a heating unit, a heating-rate controller, anda digital tempe
21、rature display.6.2 RingA brass, shouldered ring conforming to thedimensions shown in Fig. 1(a).6.3 BallA steel ball, 9.53 6 0.1 mm (38 in.) in diameter,weighing between 3.45 and 3.55 g.6.4 Ball-Centering Guide (optional), having the dimensionsgiven in Fig. 1(c).6.5 Beaker, 600 mL, borosilicate glass
22、, to hold the bathliquid. ensure that the dimensions will properly fit the heatingunit.6.6 StirrerEither a magnetic stirring motor and a mag-netic stir bar, or a direct-driven agitator with a stirring motor.The dimensions of a stir bar must be such that the bar spinsfreely under the test assembly. T
23、he bath must be stirred at aFIG. 1 Shouldered Ring, Ring Holder, Ball-Centering Guide, and Assembly of ApparatusD6493052speed sufficient to ensure uniform temperature distributionwithout causing significant sideways displacement of the resinas it sags below the ring.7. Reagents and Materials7.1 Bath
24、 Liquids:7.1.1 Distilled or Deionized Water, Freshly BoiledForsoftening points between 35C (95F) and 80C (176F).7.1.1.1 Use distilled or deionized water that has been cooledto at least 27C (81F) below the anticipated softening point,but in no case lower than 5C (41F).7.1.2 USP GlycerinFor softening
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD64932005STANDARDTESTMETHODSFORSOFTENINGPOINTOFHYDROCARBONRESINSBYAUTOMATEDRINGANDBALLAPPARATUS 自动

链接地址:http://www.mydoc123.com/p-522665.html