ASTM D6413-2008 346 Standard Test Method for Flame Resistance of Textiles (Vertical Test)《织物火焰抗性的标准试验方法(垂直试验)》.pdf
《ASTM D6413-2008 346 Standard Test Method for Flame Resistance of Textiles (Vertical Test)《织物火焰抗性的标准试验方法(垂直试验)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6413-2008 346 Standard Test Method for Flame Resistance of Textiles (Vertical Test)《织物火焰抗性的标准试验方法(垂直试验)》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6413 08Standard Test Method forFlame Resistance of Textiles (Vertical Test)1This standard is issued under the fixed designation D 6413; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to measure the vertical flameresistance of textiles.1.1.1 As a part of the measure of flame resistance, after-fla
3、me and afterglow characteristics are evaluated.1.2 This standard shall be used to measure and describe theresponse of materials, products, or assemblies to heat and flameunder controlled laboratory conditions and shall not be used todescribe or appraise the fire hazard or fire risk of materials,prod
4、ucts, or assemblies under actual fire conditions.1.3 The values stated in either SI units or other units are tobe regarded separately. The values stated in each system are notexact equivalents; therefore, each system shall be used inde-pendently without combining values.1.4 This standard does not pu
5、rport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D
6、 123 Terminology Relating to TextilesD 1776 Practice for Conditioning and Testing TextilesD 4391 Terminology Relating to The Burning Behavior ofTextiles3. Terminology3.1 DefinitionsFor definitions of terms relating to thecombustion of textiles, see Terminology D 4391. For defini-tions of other texti
7、le terms used in this test method, refer toTerminology D 123.3.2 Definitions of Terms Specific to This Standard:3.2.1 afterflame, npersistent flaming of a material afterthe ignition source has been removed.3.2.2 after-flame time, nthe length of time for which amaterial continues to flame after the i
8、gnition source has beenremoved.3.2.3 afterglow, nglow in a material after the removal ofan external ignition source or after the cessation (natural orinduced) of flaming of the material.3.2.4 afterglow time, nthe time afterglow continues afterthe removal of the ignition source and the cessation of f
9、laming.3.2.5 char length, nin measuring flame resistance oftextiles, the distance from the fabric edge, which is directlyexposed to the flame to the furthest point of visible fabricdamage after a specified tearing force has been applied.3.2.6 charring, nthe formation of carbonaceous residue asthe re
10、sult of pyrolysis or incomplete combustion.3.2.7 flame, nas related to ignition of textiles, a controlledhot, luminous zone of gas or matter in gaseous suspension, orboth, of constant size and shape that is undergoing combustionas evidenced by a low-intensity heat flux of less than 1 kw,such as cand
11、le flame or match flame.3.2.8 flame application time, nthe time interval for whichthe ignition flame is applied to a material.3.2.9 flame resistance, nthe property of a materialwhereby flaming combustion is prevented, terminated, orinhibited following application of a flaming or nonflamingsource of
12、ignition, with or without subsequent removal of theignition source.3.2.10 glow, nvisible, flameless combustion of the solidphase of a material.3.2.11 ignition, nthe initiation of combustion.3.2.12 melting, na liquification of material under theinfluence of heat.3.2.13 smoldering, nthe combustion of
13、a solid materialwithout accompaniment of flame but generally with the pro-duction of smoke.4. Summary of Test Method4.1 A specimen is positioned vertically above a controlledflame and exposed for a specified period of time. The flamethen is removed, and afterflame time and afterglow time aremeasured
14、.4.2 Char length is measured under a specified force.1This test method is under the jurisdiction of ASTM Committee D13 Textilesand is the direct responsibility of Subcommittee D13.52 on Flammability.Current edition approved July 15, 2008. Published October 2008. Discontinuedin 2008 and reinstated as
15、 D 6413 08. Last previous edition approved in 1999 asD 641399.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website
16、.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 Any evidence of melting or dripping is noted.5. Significance and Use5.1 This test method determines the response of textiles to astandard ignition source, deriving measurement valu
17、es forafterflame time, afterglow time, and char length.5.2 The vertical flame resistance, as determined by this testmethod, only relates to a specified flame exposure and appli-cation time.5.3 This test method maintains the specimen in a static,draft-free, vertical position and does not involve move
18、mentexcept that resulting from the exposure.5.4 Test Method D 6413 has been adopted from Federal TestStandard No. 191A method 5903.1, which has been used formany years in acceptance testing. The between-laboratoryprecision of this test method has not been established. Refer toSection 14 for single-l
19、aboratory precision.5.4.1 If there are differences or practical significance be-tween reported test results for two laboratories (or more),comparative tests should be performed to determine if there isa statistical bias between them, using competent statisticalassistance. As a minimum, the test samp
20、les used should be ashomogeneous as possible, that are drawn from the materialfrom which the disparate test results are obtained, and that areassigned randomly in equal numbers to each laboratory fortesting. Other materials with established test values may beused for this purpose. The test results f
21、rom the two laboratoriesshould be compared using a statistical test for unpaired data, ata probability level chosen prior to the testing series. If a bias isfound, either its cause must be found and corrected, or futuretest results must be adjusted in consideration on the knownbias.6. Apparatus6.1 T
22、est Cabinet and Accessories, fabricated in accordancewith the requirements specified in Figs. 1-5. Galvanized sheetmetal or other suitable metal can be used. The entire insideback wall of the cabinet shall be painted black to facilitate theviewing of the test specimen and pilot flame.6.1.1 The test
23、cabinet shall be set up in a laboratory hood orwith comparable equipment so that combustion gases can beremoved from the test lab environment. Precautions must betaken to minimize the draft through the laboratory hood whiletesting. Open doors or windows are examples of unnecessarycauses of drafts an
24、d must be avoided. A ventilation smoke tubekit3may be used to check for the presence of drafts.6.2 Burner, equipped with a needle valve to adjust flameheight (see Fig. 4).6.2.1 The burner shall be constructed by combining a 10mm (0.38 in.) inside diameter barrel 76 6 6mm(36 0.25 in.)long with a base
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD64132008346STANDARDTESTMETHODFORFLAMERESISTANCEOFTEXTILESVERTICALTEST 织物 火焰 抗性 标准 试验 方法 垂直 PDF

链接地址:http://www.mydoc123.com/p-522451.html