ASTM D6385-1999(2006) Standard Test Method for Determining Acid Extractable Content in Activated Carbon by Ashing《通过灰化对活性碳中酸可提取含量的标准试验方法》.pdf
《ASTM D6385-1999(2006) Standard Test Method for Determining Acid Extractable Content in Activated Carbon by Ashing《通过灰化对活性碳中酸可提取含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6385-1999(2006) Standard Test Method for Determining Acid Extractable Content in Activated Carbon by Ashing《通过灰化对活性碳中酸可提取含量的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6385 99 (Reapproved 2006)Standard Test Method forDetermining Acid Extractable Content in Activated Carbonby Ashing1This standard is issued under the fixed designation D 6385; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is to be used for determination of theacid extractable content of a sample of act
3、ivated carbon. Thistest method presupposes the existence of substances other thancarbon to be present with activated carbon but does not purportto address or identify those substances which may be present.This test method should be applicable to any form in whichactivated carbon may exist and requir
4、es the performance ofTest Method D 2866.1.2 This test method requires the use of concentratedhydrochloric acid, which should be used in an appropriate andsafe manner, with eye protection, skin protection and handlingcarried out in a properly operating fume hood. The proper useof a muffle furnace is
5、addressed in Test Method D 2866.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determines the applica-bility of regulatory limitat
6、ions prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 2866 Test Method for Total Ash Content of ActivatedCarbonD 2867 Test Methods for Moisture in Activated CarbonE 300 Practice for Sampling Industrial Chemicals3. Summary of Test Method3.1 The percent a
7、cid extractable content of an activatedcarbon sample is determined by the difference between thepercent mass of total ash of a sample and the percent mass oftotal ash of a sample which has been acid extracted.4. Significance and Use4.1 The quantitative determination of acid extractable con-tent is u
8、seful in evaluating activated carbon samples thatcontain acid soluble impurities. These acid soluble impuritiescan affect applications of activated carbon.4.2 Limitations of MethodHydrochloric acid is used inthis test method as the extracting acid. All elements orcompounds present in the activated c
9、arbon sample, which canbe acid extracted, are assumed to form water soluble chloridesalts. Hydrochloric acid may not solubilize all impurities ofactivated carbon.5. Apparatus5.1 250-mL Glass Beakers, for boiling and drying thesample.5.2 Watch Glass, suitable for 250-mL beaker.5.3 Graduated Cylinders
10、, of 100-mL (TD) and 25-mL (TD)size.5.4 Buchner Vacuum Funnel, 7-cm ID or equivalent filteringdevice.5.5 Vacuum Filter Flask, with side arm, 500 mL.5.6 Vacuum Filter Collar, for the above filter flask.5.7 Filter Paper, which is hardened, ashless paper, # 8micron pore size and 7 cm in diameter is rec
11、ommended, or adiameter which matches the vacuum funnel. The paper will beashed with the carbon, so ashless paper is necessary.5.8 Drying Oven, maintained at 150 C 6 5C.5.9 Muffle Furnace, as specified in Test Method D 2866.5.10 Porcelain Crucibles, as specified in Test MethodD 2866.5.11 Desicator, c
12、ontaining indicating silica gel or any otherdesicant, which is effective in maintaining dryness of coolinghot crucibles or oven dried carbon samples.5.12 Balance, capable of measurement of 0.1 mg.5.13 Carbon Particle Size Reduction, a mortar and pestle, orany other means of systematically reducing a
13、ctivated carbonparticle size to pass through a No. 325 U.S. mesh screen. The1This test method is under the jurisdiction of ASTM Committee D28 on LiquidPhase Evaluation.Current edition approved Oct. 1, 2006. Published November 2006. Originallyapproved in 1999. Last previous edition approved in 1999 a
14、s D 6385 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dr
15、ive, PO Box C700, West Conshohocken, PA 19428-2959, United States.size reduction device must be constructed of material that willnot contaminate the carbon sample with acid soluble materials.5.14 No. 325 U.S. Mesh Screen, for sieving the sample aftersize reduction.6. Reagents6.1 Concentrated Hydroch
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD638519992006STANDARDTESTMETHODFORDETERMININGACIDEXTRACTABLECONTENTINACTIVATEDCARBONBYASHING 通过 灰化

链接地址:http://www.mydoc123.com/p-522361.html