ASTM D6371-2005(2010) 4375 Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels《柴油机和加热燃料冷过滤器接插点的标准试验方法》.pdf
《ASTM D6371-2005(2010) 4375 Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels《柴油机和加热燃料冷过滤器接插点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6371-2005(2010) 4375 Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels《柴油机和加热燃料冷过滤器接插点的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6371 05 (Reapproved 2010)Standard Test Method forCold Filter Plugging Point of Diesel and Heating Fuels1This standard is issued under the fixed designation D6371; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the coldfilter plugging point (CFPP) temperature of diesel and dome
3、s-tic heating fuels using either manual or automated apparatus.NOTE 1This test method is technically equivalent to test methodsIP 309 and EN 116.1.2 The manual apparatus and automated apparatus are bothsuitable for referee purposes.1.3 This test method is applicable to distillate fuels, includ-ing t
4、hose containing a flow-improving or other additive,intended for use in diesel engines and domestic heatinginstallations.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 WARNINGMercury has been designated by manyregulatory
5、 agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data
6、Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.6 This standard does not purport to address all of thesafety concern
7、s, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see Section 7.2. Referenced Documents2.1 ASTM Standa
8、rds:2D2500 Test Method for Cloud Point of Petroleum ProductsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD5771 Test Method for Cloud Point of Petroleum Products(Optical Detection Stepped Cooling Method)D5
9、772 Test Method for Cloud Point of Petroleum Products(Linear Cooling Rate Method)D5773 Test Method for Cloud Point of Petroleum Products(Constant Cooling Rate Method)E1 Specification for ASTM Liquid-in-Glass Thermometers2.2 IP Standards:3IP 309 Diesel and domestic heating fuels - Determination ofcol
10、d filter plugging pointSpecifications for IP Standard Thermometers2.3 ISO Standards:4IP 3310 Test sieves - Technical requirements and testing -Part 1: Metal cloth2.4 European Standards:5EN 116 Diesel and domestic heating fuels - Determinationof cold filter plugging point3. Terminology3.1 Definitions
11、 of Terms Specific to This Standard:1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved Aug. 1, 2010. Published November 2010. Originallyapproved in 19
12、99. Last previous edition approved in 2005 as D637105. DOI:10.1520/D6371-05R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
13、nthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from European Committee for Standardiz
14、ation (CEN), 36 rue deStassart, B-1050, Brussels, Belgium, http:/www.cenorm.be.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.1 certified reference material, na stable petroleumproduct with a method-specific nominal CFPP value e
15、stab-lished by a method-specific interlaboratory study followingRR:D02-10076guidelines or ISO Guides 34 and 35.43.1.2 cold filter plugging point, nhighest temperature,expressed in multiples of 1C, at which a given volume of fuelfails to pass through a standardized filtration device in aspecified tim
16、e when cooled under the conditions prescribed inthis test method.4. Summary of Test Method4.1 A specimen of the sample is cooled under specifiedconditions and, at intervals of 1C, is drawn into a pipet undera controlled vacuum through a standardized wire mesh filter.The procedure is repeated, as the
17、 specimen continues to cool,for each 1C below the first test temperature. Testing iscontinued until the amount of wax crystals that have separatedout of solution is sufficient to stop or slow down the flow sothat the time taken to fill the pipet exceeds 60 s or the fuel failsto return completely to
18、the test jar before the fuel has cooled bya further 1C.4.2 The indicated temperature at which the last filtrationwas commenced is recorded as the CFPP.5. Significance and Use5.1 The CFPP of a fuel is suitable for estimating the lowesttemperature at which a fuel will give trouble-free flow incertain
19、fuel systems.5.2 In the case of diesel fuel used in European light dutytrucks, the results are usually close to the temperature of failurein service except when the fuel system contains, for example,a paper filter installed in a location exposed to the weather orif the filter plugging temperature is
20、 more than 12C below thecloud point value in accordance with Test Method D2500,D5771, D5772,orD5773. Domestic heating installations areusually less critical and often operate satisfactorily at tempera-tures somewhat lower than those indicated by the test results.5.3 The difference in results obtaine
21、d from the sample asreceived and after heat treatment at 45C for 30 min can beused to investigate complaints of unsatisfactory performanceunder low temperature conditions.6. Apparatus6.1 Manual Apparatus:6.1.1 The apparatus, as detailed in 6.1.2-6.1.13, shall bearranged as shown in Fig. 1.6.1.2 Test
22、 Jar, cylindrical, of clear glass, flat bottomed, withan internal diameter of 31.5 6 0.5 mm, a wall thickness of 1.2560.25 mm and a height of 120 6 5 mm. The jar shall have apermanent mark at the 45 6 1 mL level.NOTE 2Test jars of the required dimensions may be obtained byselection from jars conform
23、ing to Test Method D2500, which specifies awider diameter tolerance.6.1.3 Jacket, brass, watertight, cylindrical, flat bottomed, tobe used as an air bath. It shall have an inside diameter of 45 60.25 mm, outside diameter of 48 6 0.25 mm, and a height of115 6 3 mm (see Fig. 2).6.1.4 Insulating Ring,
24、made from oil-resistant plastics orother suitable material, to be placed in the bottom of the jacket(see 6.1.3) to provide insulation for the bottom of the test jar.It shall fit closely inside the jacket and have a thickness of 6 +0.3 - 0.0 mm.6.1.5 Spacers (two), approximately 5-mm thick, made ofoi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6371200520104375STANDARDTESTMETHODFORCOLDFILTERPLUGGINGPOINTOFDIESELANDHEATINGFUELS 柴油机 加热 燃料 过滤器

链接地址:http://www.mydoc123.com/p-522307.html