1、Designation: D 6290 05Standard Test Method forColor Determination of Plastic Pellets1This standard is issued under the fixed designation D 6290; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is intended primarily for the instru-mental measurement of the degree of yellowness (or change ofdegree of yellowness) under
3、daylight illumination of homoge-neous, nonfluorescent, nearly-colorless transparent or nearly-white translucent or opaque plastics. The measurement is madeon pellets and based on tristimulus values obtained with aspectrophotometer or colorimeter.1.2 This test method is applicable to the color analys
4、is ofplastic pellets. Each material may have unique characteristicsthat determine the color values.1.3 This procedure outlines a method to determine colormeasurements, such as Yellowness Index, CIE X, Y, Z, andHunter L, a, b, or CIE L*, a*, b*.1.4 This standard does not purport to address all of the
5、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no equivalent ISO Standard.2. Referenced Documents2.1 AS
6、TM Standards:2D 883 Terminology Relating to PlasticsD 2244 Test Method for Calculation of Color Differencesfrom Instrumentally Measured Color CoordinatesE 179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE 284 Terminology of Appearan
7、ceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 313 Test Method for Indexes of Whiteness and Yellow-ness of Near-White Opaque MaterialsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1331 Test Method for Reflectance Fact
8、or and Color bySpectrophotometry Using Hemispherical GeometryE 1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus (Filter) ColorimetryE 1349 Test Method for Reflectance Factor and Color bySpectrophotometry Using Bidirectional Geometry3. Terminology3.1 Definitions Refer to Te
9、rminologies D 883 and E 284for definitions of terms used in this test method.4. Significance and Use4.1 Before proceeding with this test method, referenceshould be made to the specification of the material being tested.Any test specimen preparation, conditioning, dimensions, ortesting parameters, or
10、 a combination thereof, covered in thematerials specification shall take precedence over those men-tioned in this test method. If there are no material specifica-tions, then default conditions apply.NOTE 2Some materials, such as polyamide (nylon), can be cooledvery differently during the production
11、of the pellets. This variation in thecooling of the pellets can result in different levels of crystallinity in thepellets only. More crystalline nylons will be more opaque than amorphousnylons. This will result in differences in pellet opacity. The pellet shape isindependent of the crystallinity of
12、the material. This variation in pelletappearance, due to varying levels of crystallinity, does not affect finalproperties.NOTE 3This test method should not be used for general materialspecifications.4.2 This test method describes a technique useful for mak-ing color comparisons of resins in pellet f
13、orm that is fast andconvenient as it does not require preparation, such as moldingor extruding specimens. The test method shall be used only tocompare specimens of similar pellet shape, size, texture, anddegree of translucency. For example, translucent disc-shapedpellets should be compared to transl
14、ucent disc-shaped pellets,not with opaque, rectangular shaped pellets.4.3 Exact measurements of resin pellet color may not bedirectly related to the color of the final cast, molded orextruded product due to the multitude of variables, such asproducing variables, methods, and pellet shape and size. C
15、olor1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.40 on Optical Properties.Current edition approved April 1, 2005. Published June 2005. Originallyapproved in 1998. Last previous edition approved in 1998 as D 6290 - 9
16、8e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this
17、 standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.measurements can be useful for comparing resins in pellet formwhen all samples are similar in shape and size.4.4 A three-number tristimulus system is necessary to quan-tify col
18、or completely and precisely. The general method used inthis procedure measures color using the CIE Systems describedin Practice E 308, Test Method D 2244, the CIE 1976 (X, Y, Z)system, and, the CIELAB 1976 color space.34.5 Individual components of the tristimulus measurementsuch as CIE Y (Luminance)
19、, Hunter L, a, b, or CIE L*, a*, b*values or other useful metrics like yellowness index can beused to describe color attributes of materials. This test methoddescribes a standard procedure on how these measurements aremade.5. Interferences5.1 Comparisons of color measurements can only be madeif the
20、material is the same, the pellet cut, size and shape areessentially the same and the test instrument is the same typeand within the same group. (See 6.2 and Section 10 and TablesA and B for instrument differences.)6. Apparatus6.1 Apparatus may be spectrophotometer, or tristimuluscolorimeter, conform
21、ing to Guide E 179.6.2 There are several different optical geometries currentlybeing used for measuring color. It is important that similaroptical geometries be used if results are to be compared. Theseare designated as Groups defined as follows:6.2.1 Group ISpectrophotometer with 45 to 52-mm portwi
22、th 0/45 directional geometry. See Test Methods E 1347 andE 1349.6.2.2 Group IIColorimeter with 52-mm port with 45/0directional geometry. See Test Methods E 1347 and E 1349.6.2.3 Group IIISphere with minimum of 25-mm port witha nominal 0/diffuse geometry. See Test Methods E 1331 andE 1347.6.2.4 Group
23、 IVSphere with minimum of 25-mm port witha nominal diffuse/0 geometry. See Test Methods E 1331 andE 1347.6.3 There may be other optical geometries being used forthis test method, which should be added if being used andbrought to our attention as this procedure is being evaluated.6.4 Calibrated tiles
24、, for instrument standardization.6.5 Glass (clear), specimen cell at least 60-mm 212-in.diameter and a minimum of 50-mm depth and black samplecover of sufficient size to prevent external light from affectingthe pellet measurement.NOTE 4The clear sample holder may be any shape that is larger thanthe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD62902005STANDARDTESTMETHODFORCOLORDETERMINATIONOFPLASTICPELLETS 塑料 颜色 测定 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-522075.html