ASTM D6288-2015 red 7418 Standard Practice for Separation and Washing of Recycled Plastics Prior to Testing《试验之前再生塑料分离和洗涤的标准实施规程》.pdf
《ASTM D6288-2015 red 7418 Standard Practice for Separation and Washing of Recycled Plastics Prior to Testing《试验之前再生塑料分离和洗涤的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6288-2015 red 7418 Standard Practice for Separation and Washing of Recycled Plastics Prior to Testing《试验之前再生塑料分离和洗涤的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6288 09D6288 15Standard Practice forSeparation and Washing of Recycled Plastics Prior toTesting1This standard is issued under the fixed designation D6288; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 TheThis practice describes a procedure for separating recycled plastics based on their color (for example, green versus
3、colorless) and a procedure for washing dirty, ground plastic, which results in separation of light materials (density 1.00 1.00g/cm3). This practice is not intended to represent generic washing procedures used in the plastics recycling industry. The describedprocedures are solely for preparation of
4、plastic samples for use in other analytical tests. The procedure includes a room temperaturewash step to facilitate separation of paper (for example, labels) followed by washing at an elevated temperature.NOTE 1Although not presented as a quantitative method, the procedure presented in this practice
5、 may be used to provide quantitative results. Theuser assumes the responsibility to verify the reproducibility of quantitative results.1.2 The values stated in SI units are to be regarded as the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated wit
6、h its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 2There is no known ISO equivalent to this practice.standard.2. Referenced Documents2.1 ASTM Standards:2D1600
7、 Terminology for Abbreviated Terms Relating to PlasticsD5814 Practice for Determination of Contamination in Recycled Poly(Ethylene Terephthalate) (PET) Flakes and Chips Usinga Plaque TestD5991 Practice for Separation and Identification of Poly(Vinyl Chloride) (PVC) Contamination in Poly(Ethylene Ter
8、ephthalate)(PET) FlakeD7209 Guide for Waste Reduction, Resource Recovery, and Use of Recycled Polymeric Materials and Products (Withdrawn2015)3IEEE/ASTM SI-10 Standard for Use of the International System of Units (SI): The Modern Metric System3. Terminology3.1 The terminology used in this practice i
9、s in accordance with Terminology D1600 and Guide D7209. Units and symbols arein accordance with Standard IEEE/ASTM SI-10.3.2 Definitions of Terms Specific to This Standard:3.2.1 light materialpaper, polymers such as polyethylene and polypropylene, and other materials with densities less than 1.00g/c
10、m3.4. Summary4.1 Different colored (for example, green versus colorless) plastic materials are readily distinguished by visual inspection of asample.1 This practice is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.95 on Recycled Plastic
11、s.Current edition approved Sept. 1, 2009Oct. 1, 2015. Published September 2009October 2015. Originally approved in 1998. Last previous edition approved in 20032009as D6288 - 98D6288 - 09.(2003). DOI: 10.1520/D6288-09.10.1520/D6288-15.2 For referencedASTM standards, visit theASTM website, www.astm.or
12、g, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and
13、 is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only t
14、he current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Labels, glue residue
15、s and other plastics may absorb the dyes used in some procedures for identifying contaminants or theseother contaminants may exhibit interfering fluorescence. Consequently, a standard procedure is provided for washing the plasticprior to examination by these tests.4.3 This practice utilizes a room t
16、emperature wash step to facilitate separation of paper (for example, labels) followed bywashing at an elevated temperature to permit separation of plastics and other contaminants based on densities. The roomtemperature wash step effectively removes labels without activating some adhesives.NOTE 3The
17、dye and fluorescence tests that may require plastic washed by this procedure are specifically designed to detect poly(vinyl chloride)(PVC) contamination.4.4 Washed recycled plastic materials are then used for tests such as those described in Practices D5814 or D5991.5. Significance and Use5.1 Dirt,
18、paper and mixtures of polymeric materials complicate the interpretation of data from procedures used to identify and,if desired, quantify the contaminants in recycled plastics.6. Apparatus6.1 Bright Aluminum Tray, shallow depth (750 mm), with minimum area of 774 cm2 (120 in.2).6.2 Balances, suitable
19、 for weighing 500 g of flake.6.3 Baffled Beaker, stainless steel, 15.2 cm (6 in.) diameter with four 1.9 cm (0.75 in.) baffles providing a slurry height/diameterratio of 0.9.6.4 Cover for Beaker (see 6.3) which can accommodate a thermometer (or other temperature sensing device) and the stirringimpel
20、ler rod.6.5 Overhead Stirrer, capable of 1000 r/min.6.6 Stirring Impeller, pitched three blade, 7.62 cm (3 in.) diameter.6.7 Plastic Pails, 19 L (5 gal).6.8 Strainer, non-aluminum to fit the pails described in 6.7.6.9 Hot Plate.6.10 Thermometer.6.11 Manual Stirring Rod.6.12 Oven, capable of drying p
21、lastic flakes at 60 6 2C.7. Materials7.1 Water, distilled or deionized.7.2 Sodium Hydroxide, granular.7.3 Detergent, nonionic surfactant.NOTE 4Nonylphenol or octylphenol derivatives are effective detergents for this procedure. Users of this procedure should be aware that thesematerials have been lin
22、ked to endocrine/estrogen activity and false positive interferences with breast cancer research. Anionic detergents may also beeffective.7.4 Wash solution, consisting of 2 L of water, 0.3 % (6 g) nonionic surfactant (see 7.3), and 1 % (20 g) sodium hydroxide (see7.2). Dissolve the surfactant in cold
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD62882015RED7418STANDARDPRACTICEFORSEPARATIONANDWASHINGOFRECYCLEDPLASTICSPRIORTOTESTING 试验 之前 再生

链接地址:http://www.mydoc123.com/p-522070.html