ASTM D6099-2013 red 7500 Standard Test Method for Polyurethane Raw Materials Determination of Acidity in Moderate to High Acidity Aromatic Isocyanates《聚氨酯原材料的标准试验方法 中等至高等酸度芳香族异氰酸酯酸.pdf
《ASTM D6099-2013 red 7500 Standard Test Method for Polyurethane Raw Materials Determination of Acidity in Moderate to High Acidity Aromatic Isocyanates《聚氨酯原材料的标准试验方法 中等至高等酸度芳香族异氰酸酯酸.pdf》由会员分享,可在线阅读,更多相关《ASTM D6099-2013 red 7500 Standard Test Method for Polyurethane Raw Materials Determination of Acidity in Moderate to High Acidity Aromatic Isocyanates《聚氨酯原材料的标准试验方法 中等至高等酸度芳香族异氰酸酯酸.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6099 08D6099 13Standard Test Method forPolyurethane Raw Materials: Determination of Acidity inModerate to High Acidity Aromatic Isocyanates1This standard is issued under the fixed designation D6099; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method determines the acidity, expressed as parts per million (pp
3、m) of HCl, in aromatic isocyanate samples ofgreater than 100ppm acidity. The test method is applicable to products derived from toluene diisocyanate and methylene-bis-(4phenylisocyanate) (see Note 1).NOTE 1This test method is equivalent to ISO 14898, Test Method A.2. Referenced Documents2.1 ASTM Sta
4、ndards:2D883 Terminology Relating to PlasticsE180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals(Withdrawn 2009)3E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 ISO Standards:I
5、SO 14898 PlasticsAromatic isocyanates for use in the production of polyurethaneDetermination of acidity43. Terminology3.1 DefinitionsTerms used in this test method are in accordance with Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 acidity, nthe acid strength of a sample
6、 expressed in ppm hydrochloric acid.HCl.4. Summary of Test Method4.1 The isocyanate is mixed with an excess of methanol and a cosolvent. Additional acid is released into the solvent systemduring urethane formation. The acid then is titrated potentiometrically with methanolic KOH, and the acidity pre
7、sent in theisocyanate sample is calculated from the titer.5. Significance and Use5.1 This test method can be used for research or for quality control to characterize aromatic isocyanates and prepolymers ofmoderate to high acidity. Acidity correlates with performance in some polyurethane systems.6. A
8、pparatus6.1 250-mL Beakers.6.2 50-mL Pipet or Repipet, Class A volumetric.6.3 100-mL Pipet or Repipet, Class A volumetric.1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.22 on Cellular Materials - Plasticsand Elastom
9、ers.Current edition approved Nov. 15, 2008Sept. 1, 2013. Published November 2008September 2013. Originally approved in 1997. Last previous edition approved in20032008 as D6099 - 03.D6099 - 08. DOI: 10.1520/D6099-08.10.1520/D6099-13.2 For referencedASTM standards, visit theASTM website, www.astm.org,
10、 or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 Available from American National Standard
11、s Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to
12、adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright A
13、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.4 Automatic Titration Equipment, capable of inflection detection and stirring the sample while, titrating, such as:6.4.1 Commerically-available Automatic Titration Apparatus,6.4.2 Reference Elect
14、rode, with saturated LiCl/ethanol solution in both chambers.6.4.3 pH Glass Electrode, (see Note 2).NOTE 2A combination pH electrode with internal reference also may be used.6.5 Magnetic Stirrer.6.6 Stir Bars.6.7 Watch Glasses.6.8 Analytical Balance, capable of weighing to the nearest 1 mg.7. Reagent
15、s and Materials7.1 0.02 N KOH in Methanol1.32 g KOH pellets (85 % KOH)/1000 mL methanol, standardized with potassium hydrogenphthalate (KHP).7.2 Toluene or 1,2,4Trichlorobenzene (TCB), dried for 24 h over molecular sieves.7.3 Anhydrous Methanol.8. Sampling8.1 Since organic isocyanates react with atm
16、ospheric moisture, take special precautions in sampling. Usual sampling methods,even when conducted rapidly, can cause contamination of the sample with insoluble urea. Therefore, blanket the sample with dryair or nitrogen at all times.NOTE 3Warning:Many diisocyanates are known or suspected sensitize
17、rs. Over-exposure to diisocyanates can lead to adverse health effects which mayinclude the development of occupational asthma and other respiratory, skin and eye effects. Engineering controls and/or personal protective equipment,including respiratory, skin and eye protection, should are to be used w
18、hen there is a potential for over-exposure to diisocyanates. The product suppliersMaterial Data Safety Sheet (MSDS) provides more detailed information about potential adverse health effects and other important safety and handlinginformation. Always follow the specific instructions provided on the MS
19、DS.9. Calibration9.1 Calibrate the electrodes using pH 4 and pH 7 aqueous buffers.10. Test Conditions10.1 Since isocyanates react with moisture, keep laboratory humidity low, preferably around 50 % relative humidity.11. Procedure11.1 All samples shall be done in duplicate.11.2 Accurately weigh to th
20、e nearest 1 mg, 10 g of sample into a 250-mL beaker.11.3 Add 50 mL of dried toluene or TCB.NOTE 4If this test method is used for prepolymers, substitute THF as the solvent. THF has been used as a solvent for prepolymers.11.4 Add 100 mL of methanol into the solution.11.5 Add a stir bar, cover with a
21、watch glass, and stir for 20 min.NOTE 5Samples must be at room temperature before titration. Warm samples cause more frequent electrode clogging.11.6 With uniform stitrring of the sample, automatically titrate the mixture with 0.02 N methanolic KOH through thepotentiometrically-determined inflection
22、 end point between apparent pH 4 and 9. Follow manufacturers instructions forinstrument-specific parameters for set-up, calibration and analysis of samples.NOTE 6If results indicate a drift in the data or a slow electrode response, the pH electrode should be cleaned by soaking in 2:1 sulfuric: nitri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60992013RED7500STANDARDTESTMETHODFORPOLYURETHANERAWMATERIALSDETERMINATIONOFACIDITYINMODERATETOHIGHACIDITYAROMATICISOCYANATES

链接地址:http://www.mydoc123.com/p-521532.html