ASTM D6072 D6072M-2009(2015) 8098 Standard Practice for Obtaining Samples of Geosynthetic Clay Liners《获得土工合成黏土衬垫垫样品的标准实践规程》.pdf
《ASTM D6072 D6072M-2009(2015) 8098 Standard Practice for Obtaining Samples of Geosynthetic Clay Liners《获得土工合成黏土衬垫垫样品的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6072 D6072M-2009(2015) 8098 Standard Practice for Obtaining Samples of Geosynthetic Clay Liners《获得土工合成黏土衬垫垫样品的标准实践规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6072/D6072M 09 (Reapproved 2015)Standard Practice forObtaining Samples of Geosynthetic Clay Liners1This standard is issued under the fixed designation D6072/D6072M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for sampling geosyn-thetic clay liners (GCLs) for the purpose of laboratory te
3、sting.These procedures are designed to ensure that representativesamples are obtained and properly packaged for submittal to atesting laboratory.1.2 The procedures in this practice may be applied to eithersamples of unhydrated GCLs obtained at the project site priorto installation (or at the product
4、ion facility, prior to shipment tothe project site) or samples exhumed from a project site afterinstallation.1.3 It is assumed that the number of samples to be obtainedhas already been determined in the project specification,standard test method, or by prior agreement between thepurchaser and seller
5、. This practice covers only the methods forobtaining a pre-arranged number of samples and does notdescribe methods for obtaining individual specimens from thesample.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system
6、may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespons
7、ibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4220 Practices for Preserving and Transporting SoilSamplesD4354 Practice for Sampling of Geos
8、ynthetics and RolledErosion Control Products(RECPs) for TestingD4439 Terminology for GeosyntheticsD5888 Guide for Storage and Handling of GeosyntheticClay Liners3. Terminology3.1 Definitions:3.1.1 geosynthetic clay liner (GCL), na manufacturedhydraulic barrier consisting of clay bonded to a layer or
9、 layersof geosynthetics.3.1.2 sample, na portion of a material which is taken fortesting or for record purposes (See Practice D4354).3.1.3 specimen, na specific portion of a material orlaboratory sample upon which a test is performed or which istaken for that purpose (See Practice D4354).3.1.4 For d
10、efinitions of other geosynthetic terms used in thispractice, refer to Terminology D4439.4. Significance and Use4.1 This practice provides a procedure by which samples ofGCL should be obtained for laboratory testing. The practiceapplies to materials obtained prior to installation (either at a jobsite
11、 or at a production facility) or exhumed material afterinstallation.4.2 Only GCL samples obtained in accordance with 5.1 ofthis practice will be considered representative of the actualmanufactured GCL for quality assurance/quality control (QA/QC) purposes4.3 The quantity of GCL received by the labor
12、atory shouldbe sufficient for the preparation of several representative testspecimens for the standardized physical, hydraulic, and me-chanical tests to be performed on the GCLs.4.4 The procedures in this practice should be used by plantand field personnel for obtaining GCL samples for laboratorytes
13、ting.5. Procedure5.1 Obtaining Samples Prior to Installation:1This practice is under the jurisdiction of ASTM Committee D35 on Geosyn-thetics and is the direct responsibility of Subcommittee D35.04 on GeosyntheticClay Liners.Current edition approved Jan. 1, 2015. Published February 2015. Originallya
14、pproved in 1996. Last previous edition approved in 2009 as D6072/D6072M09.DOI: 10.1520/D6072_D6072M-09R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standa
15、rds Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.1.1 In accordance with the project specifications or withPractice D4354, divide the shipment or other given quantity ofGCL into lots, and s
16、elect lot and laboratory samples. This willusually involve the selection of a certain number of finishedGCL rolls from which samples will be cut.5.1.2 Affix on the packaging of the GCL rolls to be sampledadhesive labels or other markings which clearly identify thatthe roll is to be sampled.5.1.3 Rec
17、ord the label information from each roll to besampled for future incorporation into within the qualityassurance/quality control (QA/QC) documentation for theGCL.5.1.4 Segregate the rolls identified for sampling. Refer toGuide D5888 for the proper equipment and techniques forhandling the GCL rolls.5.
18、1.5 Inspect the packaging of the selected GCL rolls fordamage. Describe and record the damage, if any.5.1.6 Remove the outer packaging from the GCL as care-fully as possible, taking precautions not to damage the GCLand to preserve the packaging as much as possible for re-useafter sampling is complet
19、ed.5.1.7 Obtain samples from the selected GCL rolls prior todeployment. If cut on a surface, the surface on which the GCLis cut shall be dry, clean, smooth, hard and free of irregularitiesand potential contaminants.NOTE 1At the discretion of the engineer, shorter or narrower samples,or both, may be
20、obtained provided that the packaging procedures in thisguide are followed.5.1.8 A unique sample number shall be written on thesample. Additional markings should be made on the sample toidentify the machine direction and the top/bottom sides of theGCL.5.1.9 The GCL sample shall then be manually rolle
21、d arounda core at least 75 mm in diameter, in the same direction as thecut. Care should be taken to wind the GCL without slack. Widestrapping tape (50 mm) shall then be wound around the samplein at least two places to secure the loose end. Bentonite lossfrom the sample may be minimized by applying t
22、he tapearound the roll ends.5.1.10 At least two layers of plastic sheeting shall be used towrap the GCL sample roll for shipment to the laboratory, so asto minimize GCL sample disturbance or changes in moisturecontent. A thin cellophane material may be used for the innerwrapping, provided it is woun
23、d securely and repeatedly aroundthe rolled sample. The outer sheeting shall be at least 0.15 mm6 mils in thickness and shall be wrapped to minimize theamount of GCL shifting within the wrapping.5.1.11 To ensure proper sample chain-of-custody tracking,all shipping documents shall indicate the sample
24、number,project name and contact, and laboratory name and contact.5.1.12 If an additional sample from the same GCL roll isrequired for testing, 5.1.6 through 5.1.10 of this practice maybe repeated on the exposed end of the roll until a sufficientamount of GCL is obtained.NOTE 2Additional material cut
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6072D6072M200920158098STANDARDPRACTICEFOROBTAININGSAMPLESOFGEOSYNTHETICCLAYLINERS 获得 土工 合成 黏土 衬垫

链接地址:http://www.mydoc123.com/p-521446.html