ASTM D5993-2014 9393 Standard Test Method for Measuring Mass Per Unit of Geosynthetic Clay Liners《测量铺地合成纤维织物粘土衬里单位质量的标准试验方法》.pdf
《ASTM D5993-2014 9393 Standard Test Method for Measuring Mass Per Unit of Geosynthetic Clay Liners《测量铺地合成纤维织物粘土衬里单位质量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5993-2014 9393 Standard Test Method for Measuring Mass Per Unit of Geosynthetic Clay Liners《测量铺地合成纤维织物粘土衬里单位质量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5993 14Standard Test Method forMeasuring Mass Per Unit of Geosynthetic Clay Liners1This standard is issued under the fixed designation D5993; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the laboratory determination ofthe mass per unit area of a sample of a geosynthetic clay liner(GCL). The test
3、 method is also applicable to a multicomponentGCL. The dry mass of the clay can be found by simplysubtracting the manufacturers reported nominal mass of thegeosynthetic component(s) from the total mass of the dry GCL.The moisture content of the GCL can also be determined bysubtracting the initial to
4、tal mass of the GCLfrom the total massof the dry GCL.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
5、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See Section 8 forspecific precautionary statements.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD4439
6、Terminology for GeosyntheticsD4643 Test Method for Determination of Water (Moisture)Content of Soil by Microwave Oven HeatingD4753 Guide for Evaluating, Selecting, and Specifying Bal-ances and Standard Masses for Use in Soil, Rock, andConstruction Materials TestingE145 Specification for Gravity-Conv
7、ection and Forced-Ventilation OvensE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 geosynthetic, na planar product manufactured frompolymeric material used with soil, rock, earth, or other geo-technical engineering r
8、elated material as an integral part of aman-made project, structure, or system. D44393.1.2 geosynthetic clay liner, na manufactured hydraulicbarrier consisting of clay bonded to a layer or layers ofgeosynthetic material(s).3.1.3 moisture content, nthat part of the mass of ageosynthetic clay liner th
9、at is absorbed water, compared to themass of dry clay.3.1.4 multicomponent GCL, nGCL with an attached film,coating, or membrane decreasing the hydraulic conductivity orprotecting the clay core, or both.3.1.5 oven-dried, adjthe condition of a material that hasbeen heated under prescribed conditions o
10、f temperature andhumidity until there is no further significant change in its mass.D1234. Summary of Test Method4.1 The mass per unit area is determined by weighing(oven-dried) specimens of known initial size after drying in anoven over a sufficient time period to remove the moisture fromthe GCL.4.2
11、 The mass per unit area of the clay component of theGCL can be estimated by subtracting the manufacturersreported nominal mass per unit area of the synthetic compo-nent(s) from the total GCL mass per unit area.NOTE 1The supplier of the geosynthetic clay liner must be able toverify that the actual ma
12、ss/unit area of the synthetic component(s) iswithin 610 % of the reported nominal value. A more accurate estimationof the actual dry clay mass per unit area could be obtained by using theactual average value for the synthetic component(s) (as obtained from themanufacturer for the actual lots used to
13、 make the GCL) rather than thenominal value.4.3 The moisture content of the GCL can be estimated withthis test method.5. Significance and Use5.1 This test method is used to determine if the GCLmaterial meets specifications for mass per unit area at approxi-mately 0 % moisture content, by oven-drying
14、. It can be used as1This test method is under the jurisdiction of ASTM Committee D35 onGeosynthetics and is the direct responsibility of Subcommittee D35.04 on Geosyn-thetic Clay Liners.Current edition approved Aug. 1, 2014. Published August 2014. Originallyapproved in 1996. Last previous edition ap
15、proved in 2009 as D5993 99(2009).DOI: 10.1520/D5993-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyri
16、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1an index test for quality control or quality assurance todetermine specimen conformance.6. Atmosphere Conditions6.1 Atmospheric Conditions:6.1.1 The atmospheric conditions of the laboratory pe
17、rform-ing mass per unit area of GCLs shall be: relative humidity of 70 % and temperature of 23 6 4C.7. Apparatus7.1 Drying OvenThermostatically-controlled, preferablyof the forced-draft type, meeting the requirements of Specifi-cation E145 and capable of maintaining a uniform temperatureof 110 6 5C
18、throughout the drying chamber.7.2 Microwave OvenAmicrowave oven, preferably with avented chamber, is suitable. The required size and power ratingof the oven is dependent on its intended use. Ovens withvariable power controls and input power ratings of about700 W have been found to be adequate for th
19、is use. Variablepower controls are important and reduce the potential for overheating the test specimen.NOTE 2Microwave ovens equipped with built-in scales and computercontrols have been developed for use in drying soils. Their use iscompatible with this test method.7.3 BalancesAll balances must mee
20、t the requirements ofSpecification D4753 and this section. A Class GP1 balance of0.01 g readability is required for samples having a mass of upto 200 g (excluding mass of sample container) and a Class GP2balance of 0.1 g readability is required for samples having amass over 200 g.7.4 Sample Containe
21、rsSuitable containers made of mate-rial resistant to corrosion and change in mass upon repeatedheating, cooling, exposure to materials of varying pH, andcleaning. Microwave sample containers should be microwavesafe.7.5 DesiccatorA desiccator cabinet or large desiccator jarof suitable size containing
22、 indicator silica gel. It is preferable touse a desiccant that changes color to indicate it needs recon-stitution.7.6 Container Handling ApparatusGloves, tongs, or suit-able holder for moving and handling hot containers afterdrying.7.7 Die, of known dimensions.7.8 Miscellaneous, knives, spatulas, sc
23、oops, quarteringcloth, sample splitters, and so forth, as required.8. Hazards/Precautions8.1 Handle hot containers with a container holder.8.2 Safety precautions supplied by the manufacturer of themicrowave oven should be observed.8.3 Do not use metallic containers in a microwave oven (ifused).9. Te
24、st Specimens9.1 The sample received at the testing laboratory should bein satisfactory condition and representative of the productmanufactured or delivered to a site, or both.9.2 A sample of a GCL should be cut into specimens in alaboratory using a die or sharp razor blade or razor knife.9.3 The min
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD599320149393STANDARDTESTMETHODFORMEASURINGMASSPERUNITOFGEOSYNTHETICCLAYLINERS 测量 铺地 合成纤维 织物 粘土 衬里

链接地址:http://www.mydoc123.com/p-521252.html