ASTM D5848-2010 4375 Standard Test Method for Mass Per Unit Area of Pile Yarn Floor Coverings.pdf
《ASTM D5848-2010 4375 Standard Test Method for Mass Per Unit Area of Pile Yarn Floor Coverings.pdf》由会员分享,可在线阅读,更多相关《ASTM D5848-2010 4375 Standard Test Method for Mass Per Unit Area of Pile Yarn Floor Coverings.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5848 10Standard Test Method forMass Per Unit Area of Pile Yarn Floor Coverings1This standard is issued under the fixed designation D5848; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of mass perunit area of machine-made woven, knitted, and tufted pile yarnfloor covering both befo
3、re and after an adhesive-back coatingapplication.1.2 This test method encompasses three techniques fordetermination of mass per unit area as applicable:1.2.1 Section 1.3, for determining total mass per unit area,applies to both coated and uncoated (unfinished) pile floorcoverings.1.2.2 Section 1.4,
4、for determining component mass per unitarea, applies only to uncoated (unfinished) pile yarn floorcoverings.1.2.3 Section 1.5, for determining pile yarn mass per unitarea, applies only to back-coated, or finished, pile yarn floorcoverings.1.3 Determination of mass per unit area of pile yarn floorcov
5、erings was previously contained within Test MethodsD418. For user convenience, Subcommittee D 13.21 subdi-vided Test Methods D418 into separate standards, of which thistest method is one.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are math
6、ematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
7、alth practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in 9.5.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD418 Methods of Testing Pile Yarn Floor Covering Con-struction3D1193 Specificati
8、on for Reagent WaterD1776 Practice for Conditioning and Testing TextilesD1909 Standard Table of Commercial Moisture Regains forTextile FibersD5684 Terminology Relating to Pile Floor CoveringsE122 Practice for Calculating Sample Size to Estimate,With Specified Precision, the Average for a Characteris
9、ticof a Lot or ProcessD2904 Practice for Interlaboratory Testing of a Textile TestMethod that Produces Normally Distributed DataD2906 Practice for Statements on Precision and Bias forTextiles33. Terminology3.1 For definitions of terms relating to Pile Floor Coverings,D13.21, refer to Terminology D56
10、84.3.1.1 The following terms are relevant to this standard: backcoating, backing, backing fabric, binding sites, buried pileyarn, carpet, components, extractable matter, finished, finishedpile yarn floor covering, floor covering, multilevel pile, pile,pile yarn floor covering, pile yarn mass, pitch,
11、 primary back-ing, secondary backing, stubble, textile floor covering, totalmass, tufted fabric.3.2 For all other terminology related to textiles, refer toTerminology D123.4. Significance and Use4.1 The determination of the mass per unit area of pile yarnfloor covering is useful in quality and cost
12、control during themanufacture of pile floor covering. Both appearance andperformance may be affected by changes in mass per unit area.4.2 In case of a dispute arising from differences in reportedtest results when using this test method for acceptance testingof commercial shipments, the purchaser and
13、 supplier shouldconduct comparison testing to determine if there is a statisticalbias between their laboratories. Competent statistical assis-tance is recommended for the investigation of bias. As aminimum the two parties should take a group of test specimensthat are as homogeneous as possible and t
14、hat are from a lot ofmaterial of the type in question. The test specimens should then1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.21 on Pile Floor Coverings.Current edition approved June 1, 2010. Published July 2010
15、. Originally approvedin 1995. Last previous edition approved in 2007 as D5848 07. DOI: 10.1520/D5848-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standard
16、s Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.be randomly assigned to each laboratory for testing. Theaverage results from the two laboratories should be comparedusing Students
17、t-test for unpaired data and an acceptableprobability level chosen by the two parties prior to testing. If abias is found, either its cause must be found and corrected orthe purchaser and supplier must agree to interpret future testresults with consideration to the known bias.5. Test Specimen5.1 Sam
18、pling Units:5.1.1 Uncoated Floor CoveringThe basic sampling unitof uncoated floor covering is a production roll.5.1.2 Coated Floor CoveringThe basic sampling unit ofcoated floor covering is a shipping roll. The number ofshipping rolls obtained from each production roll ranges fromone to over ten.5.2
19、 Lot SampleTake a lot sample as directed in PracticeE122 when statistical knowledge of the product variability andtest method precision is available, and a decision has beenmade on the maximum deviation that can be tolerated betweenthe estimate to be made from the sample and the result thatwould be
20、obtained by measuring every sampling unit of the lot.Otherwise the number of sampling units in a lot sample and theuse of the test results obtained from the individual test samplesshall be in accordance with the manufacturers quality controlprogram or with the specification agreed upon between thepu
21、rchaser and the supplier.5.3 Laboratory Sampling UnitAlaboratory sampling unitshall consist of a full width section of floor covering cut fromone end of each roll in the lot sample and shall be at least 4 in.(100 mm) longer than the specimens required for the testsbeing conducted. Do not cut a labor
22、atory sampling unit ofcoated floor covering from a seam end of a production roll.5.4 Test Specimens:5.4.1 A test specimen is a designated area of a test samplecut from the test sample. For test samples 120 in. (3000 mm)wide or wider, three test specimens are required for a testmethod, one at each ed
23、ge no nearer to the edge than 5 % of thetotal floor covering width and one in the middle portion of thetest sample. For test samples at least 60 in. (1500 mm) wide butless than 120 in. (3000 mm), take two test specimens, one ateach edge no nearer to the edge than 5 % of the total floorcovering width
24、. For test samples less than 60 in. (1500 mm)wide, take one specimen from the middle.5.4.2 Where it is known that systematic variations in a floorcovering characteristic may occur in bands 18 in. (460 mm) ormore in width, as with a modular pattern device havingseparate controls or adjustments for ea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD584820104375STANDARDTESTMETHODFORMASSPERUNITAREAOFPILEYARNFLOORCOVERINGSPDF

链接地址:http://www.mydoc123.com/p-520850.html