ASTM D5674-1995(2008) 516 Standard Guide for Operation of a Gaging Station《测量站工作的标准指南》.pdf
《ASTM D5674-1995(2008) 516 Standard Guide for Operation of a Gaging Station《测量站工作的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5674-1995(2008) 516 Standard Guide for Operation of a Gaging Station《测量站工作的标准指南》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5674 95 (Reapproved 2008)Standard Guide forOperation of a Gaging Station1This standard is issued under the fixed designation D 5674; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、 in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The guide covers procedures used commonly for thesystematic collection of streamflow information. Continuousstreamflow information is necessa
3、ry for understanding theamount and variability of water for many uses, including watersupply, waste dilution, irrigation, hydropower, and reservoirdesign.1.2 The procedures described in this guide are used widelyby those responsible for the collection of streamflow data, forexample, the U.S. Geologi
4、cal Survey, Bureau of Reclamation,U.S. Army Corps of Engineers, U.S. Department of Agricul-ture, Water Survey Canada, and many state and provincialagencies. The procedures are generally from internal docu-ments of the preceding agencies, which have become thedefacto standards used in North America.1
5、.3 It is the responsibility of the user of the guide todetermine the acceptability of a specific device or procedure tomeet operational requirements. Compatibility between sensors,recorders, retrieval equipment, and operational systems isnecessary, and data requirements and environmental operatingco
6、nditions must be considered in equipment selection.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport
7、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129
8、 Terminology Relating to WaterD 1941 Test Method for Open Channel Flow Measurementof Water with the Parshall FlumeD 3858 Test Method for Open-Channel Flow Measurementof Water by Velocity-Area MethodD 5129 Test Method for Open Channel Flow Measurementof Water Indirectly by Using Width ContractionsD 5
9、130 Test Method for Open-Channel Flow Measurementof Water Indirectly by Slope-Area MethodD 5242 Test Method for Open-Channel Flow Measurementof Water with Thin-Plate WeirsD 5243 Test Method for Open-Channel Flow Measurementof Water Indirectly at CulvertsD 5388 Test Method for Indirect Measurements o
10、f Dis-charge by Step-Backwater MethodD 5389 Test Method for Open-Channel Flow Measurementby Acoustic Velocity Meter SystemsD 5390 Test Method for Open-Channel Flow Measurementof Water with Palmer-Bowlus FlumesD 5413 Test Methods for Measurement of Water Levels inOpen-Water BodiesD 5541 Practice for
11、Developing a Stage-Discharge Relationfor Open Channel Flow2.2 ISO Standards:3ISO 1100 Liquid Flow Measurement in Open ChannelsPart I: Establishment and Operation of a Gauging StationISO 6416 Measurement of Discharge by Ultrasonic (Acous-tic) Method3. Terminology3.1 Definitions: For definitions of te
12、rms used in this guide,refer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 controlthe physical properties of a channel, whichdetermine the relationship between the stage and discharge ofa location in the channel.3.2.2 datuma level plane that represents zero elevation
13、.3.2.3 dischargethe volume of water flowing through across-section in a unit of time, including sediment or othersolids that may be dissolved in or mixed with the water; usuallycubic feet per second (f3/s) or metres per second (m/s).3.2.4 elevationthe vertical distance from a datum to apoint; also t
14、ermed stage or gage height.1This guide is under the jurisdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.07 on Sediments, Geomorphology,and Open-Channel Flow.Current edition approved Oct. 1, 2008. Published November 2008. Originallyapproved in 1995. Last pr
15、evious edition approved in 2003 as D 5674 95 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Measurem
16、ent of Liquid Flow in Open Channels, ISO Standards Handbook 16,1983.Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5 gagea
17、generic term that includes water level mea-suring devices.3.2.6 gage datuma datum whose surface is at the zeroelevation of all of the gages at a gaging station. This datum isoften at a known elevation referenced to the national geodeticvertical datum (NGVD) of 1929.3.2.7 gage heightthe height of a w
18、ater surface above anestablished or arbitrary datum at a particular gaging station;also termed stage.3.2.8 gaging stationa particular site on a stream, canal,lake, or reservoir at which systematic observations of hydro-logic data are obtained.3.2.9 national geodetic vertical datum (NGVD) of 1929prio
19、r to 1973 known as mean sea level datum, a spheroidaldatum in the conterminous United States and Canada thatapproximates mean sea level but does not necessarily agreewith sea level at a specific location.3.2.10 stilling wella well connected to the stream withintake pipes in such a manner that it per
20、mits the measurementof stage in relatively still water.4. Summary of Guide4.1 A gaging station is usually installed where a continuousrecord of stage or discharge is required. A unique relationshipexists between water surface elevation and discharge (flowrate) in most freely flowing streams. Water-l
21、evel recordinginstruments continuously record the water surface elevation,usually termed stage or gage height. Discharge measurementsare taken of the stream discharge to develop a stage-dischargecurve. The discharge data are computed from recorded stagedata by a stage-discharge rating curve.5. Signi
22、ficance and Use5.1 This guide is useful when a systematic record of watersurface elevation or discharge is required at a specific location.Some gaging stations may be operated for only a few months;however, many have been operated for a century.5.2 Gaging station records are used for many purposes:5
23、.2.1 Resource appraisal of long-term records to determinethe maximum, minimum, and variability of flows of a particu-lar stream. These data can be used for the planning and designof a variety of surface water-related projects such as watersupply, flood control, hydroelectric developments, irrigation
24、,recreation, and waste assimilation.5.2.2 Management, where flow data are required for theoperation of a surface-water structure or other managementdecision.6. Site Location6.1 The general location of the station will be dependent onthe purpose for which the station is established. Locationconstrain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD567419952008516STANDARDGUIDEFOROPERATIONOFAGAGINGSTATION 测量 工作 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-520410.html