《ASTM D5627-2017 red 8125 Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5627-2017 red 8125 Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5627 94 (Reapproved 2009)1D5627 17Standard Test Method forWater Extractable Residue from Particulate Ion-ExchangeResins1This standard is issued under the fixed designation D5627; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEAdded research report information to Section 13 editorially in November 2010.1. Scope1.1 This test met
3、hod covers the measurement of water soluble extractable residue from particulate ion-exchange resins basedon elevated temperature extraction and gravimetric determination of residue.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this s
4、tandard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limit
5、ations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Tech
6、nical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2187 Test Methods and Practices for Evaluating Physical and Chemical Properties of Particulate Ion-Exchange ResinsD2687 Practices for Sampling P
7、articulate Ion-Exchange MaterialsD2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water3. Terminology3.1 DefinitionsDefinitions: For definitions of terms used in this test method, refer to Terminology D1129.3.1.1 For definitions of terms used in t
8、his standard, refer to Terminology D1129.4. Summary of Test Method4.1 A sample of particulate ion exchange material is contacted with water at an elevated temperature. After a specified contacttime, the concentration of soluble material in the aqueous phase is measured gravimetrically after filtrati
9、on.5. Significance and Use5.1 The presence of water extractables in ion-exchange resins can cause fouling of other materials downstream andcontamination of process water. The quantity of water extractables is sometimes used as a specification to indicate resin quality,and typical values are 0.01 to
10、0.1 %.5.2 It is recognized that this test method may not remove all potential sloughage products and does not measure volatilecompounds. More extensive extraction and identification of compounds may be needed in specific cases.1 This test method is under the jurisdiction of ASTM Committee D19 on Wat
11、er and is the direct responsibility of Subcommittee D19.08 on Membranes and Ion ExchangeMaterials.Current edition approved May 1, 2009Nov. 1, 2017. Published June 2009November 2017. Originally approved in 1994. Last previous edition approved in 20042009 asD5627 94 (2009)1 (2004). . DOI: 10.1520/D562
12、7-94R09E01.10.1520/D5627-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM stan
13、dard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all case
14、s only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Interferences6.1 The hygroscopic nature of some extracted compounds can make i
15、t difficult to obtain a constant weight. Other extractiontimes and temperatures may give results that are not comparable to these.7. Apparatus7.1 Funnel, 60 mL with coarse frit.7.2 Filtration assembly.7.3 Glass fiber filters, without binder, pre-rinsed with water.37.4 Weighing vesselPlatinum, nickel
16、, or aluminum may be used so long as there is no attack by the sample and constant weightcan be achieved.7.5 Water bath, for use at 60 6 1C.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents shall conform t
17、o the specifications of the Committee on Analytical Reagents of the American Chemical Society, wheresuch specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the de
18、termination.8.2 Purity of WaterUnless otherwise indicated, references to water shall be understood to mean reagent water conforming toSpecification D1193, Type I or lI.II.9. Sampling9.1 Collect the sample in accordance with Practices D2687. In-service resins are taken after regeneration and rinse.10
19、. Procedure10.1 Drain the sample, if necessary, with the draining apparatus described in the draining apparatus section of Test MethodsD2187 to remove free water. Do not wash.10.2 Weigh (to the nearest 0.1 g) two 50-g portions of the drained sample into clean, dry, 250-mL Erlenmeyer flasks (withstop
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD56272017RED8125STANDARDTESTMETHODFORWATEREXTRACTABLERESIDUEFROMPARTICULATEIONEXCHANGERESINS 颗粒状

链接地址:http://www.mydoc123.com/p-520281.html