ASTM D5627-1994(2009) 346 Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf
《ASTM D5627-1994(2009) 346 Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5627-1994(2009) 346 Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5627 94 (Reapproved 2009)Standard Test Method forWater Extractable Residue from Particulate Ion-ExchangeResins1This standard is issued under the fixed designation D 5627; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of watersoluble extractable residue from particulate ion-exchan
3、ge res-ins based on elevated temperature extraction and gravimetricdetermination of residue.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, ass
4、ociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 1193 Specification
5、 for Reagent WaterD 2187 Test Methods for Physical and Chemical Propertiesof Particulate Ion-Exchange ResinsD 2687 Practices for Sampling Particulate Ion-ExchangeMaterialsD 2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on Water3. Terminology3.1 Defi
6、nitions:3.1.1 For definitions of terms used in this test method, referto Terminology D 1129.4. Summary of Test Method4.1 A sample of particulate ion exchange material is con-tacted with water at an elevated temperature. After a specifiedcontact time, the concentration of soluble material in theaqueo
7、us phase is measured gravimetrically after filtration.5. Significance and Use5.1 The presence of water extractables in ion-exchangeresins can cause fouling of other materials downstream andcontamination of process water. The quantity of water extract-ables is sometimes used as a specification to ind
8、icate resinquality, and typical values are 0.01 to 0.1 %.5.2 It is recognized that this test method may not remove allpotential sloughage products and does not measure volatilecompounds. More extensive extraction and identification ofcompounds may be needed in specific cases.6. Interferences6.1 The
9、hygroscopic nature of some extracted compoundscan make it difficult to obtain a constant weight. Otherextraction times and temperatures may give results that are notcomparable to these.7. Apparatus7.1 Funnel, 60 mL with coarse frit.7.2 Filtration assembly.7.3 Glass fiber filters, without binder, pre
10、-rinsed with wa-ter.37.4 Weighing vesselPlatinum, nickel, or aluminum maybe used so long as there is no attack by the sample and constantweight can be achieved.7.5 Water bath, for use at 60 6 1C.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indi
11、cated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.08 on Membranes and IonE
12、xchange Materials.Current edition approved May 1, 2009. Published June 2009. Originallyapproved in 1994. Last previous edition approved in 2004 as D 5627 94 (2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Boo
13、k of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Gelman Type A/E, Millipore Type AP40, Whatman GF/C, or equivalent, havebeen found suitable for this purpose.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
14、 19428-2959, United States.where such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, referencest
15、o water shall be understood to mean reagent water conformingto Specification D 1193, Type I or lI.9. Sampling9.1 Collect the sample in accordance with Practices D 2687.In-service resins are taken after regeneration and rinse.10. Procedure10.1 Drain the sample, if necessary, with the drainingapparatu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD562719942009346STANDARDTESTMETHODFORWATEREXTRACTABLERESIDUEFROMPARTICULATEIONEXCHANGERESINS 颗粒状

链接地址:http://www.mydoc123.com/p-520279.html