1、Designation: D 5550 06Standard Test Method forSpecific Gravity of Soil Solids by Gas Pycnometer1This standard is issued under the fixed designation D 5550; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the specificgravity of soil solids by means of a gas pycnometer. Particlesize is limit
3、ed by the dimensions of the specimen container ofthe particular pycnometer being used.1.2 Test Method D 854 may be used instead of or inconjunction with this test method for performing specificgravity tests on soils. Note that Test Method D 854 does notrequire the specialized test apparatus needed b
4、y this testmethod. However, Test Method D 854 may not be used if thespecimen contains matter that can readily dissolve in water,whereas this test method does not have that limitation.1.3 All measured and calculated values shall conform to theguidelines for significant digits and rounding established
5、 inPractice D 6026.1.3.1 For purposes of comparing, a measured or calculatedvalue(s) with specifies limits, the measured or calculatedvalue(s) shall be rounded to the nearest decimal or significantdigits in the specified limits.1.3.2 The procedures used to specify how data are collected/recorded and
6、 calculated in this standard are regarded as theindustry standard. In addition, they are representative of thesignificant digits that should generally be retained. The proce-dures used do not consider material variation, purpose forobtaining the data, special purpose studies, or any consider-ations
7、for the users objectives; and it is common practice toincrease or reduce significant digits of reported data to becommensurate with these considerations. It is beyond the scopeof this standard to consider significant digits used in analysismethods for engineering design.1.4 The values stated in acce
8、ptable SI units are to beregarded as the standard. The inch-pound units given inparentheses are for information only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priat
9、e safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 653 Terminology Relating to Soil, Rock, and ContainedFluidsD 854 Test Methods for Specific Gravity of Soil Solids byWater PycnometerD 3740 Practice for M
10、inimum Requirements for AgenciesEngaged in the Testing and/or Inspection of Soil and Rockas Used in Engineering Design and ConstructionD 4753 Guide for Evaluating, Selecting, and SpecifyingBalances and Standard Masses for Use in Soil, Rock, andConstruction Materials TestingD 6026 Practice for Using
11、Significant Digits in Geotechni-cal Data3. Terminology3.1 Definitions:3.1.1 The definitions of terms used in this test method shallbe in accordance with Terminology D 653.3.2 Definitions of Terms Specific to This Standard:3.2.1 specific gravitythe ratio of the mass in air of a givenvolume of solids
12、to the mass in air of an equal volume ofdistilled water at a temperature of 4C (in accordance withTerminology D 653).NOTE 1Distilled water at a temperature of 4C has a density of 1.000g/cm3. It is recommended that this test method be performed at or nearroom temperature. The temperature at which the
13、 soil volume is measuredcan be reported but is not required by this test method because of thenegligible effect of temperature on the volume of soil solids. However,temperature may have a significant effect on performance of the gaspycnometer. Therefore, testing should be conducted within the specif
14、iedoperating temperature range of the apparatus.4. Summary of Test Method4.1 This test method is used to determine the specificgravity of soil grains using a gas pycnometer. This test methodalso contains equations for correcting the initial specific gravityvalue for dissolved matter within the pore
15、fluid.1This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.03 on Texture, Plasticityand Density Characteristics of Soils.Current edition approved Nov. 1, 2006. Published December 2006. Originallyapproved in 1994. Last p
16、revious edition approved in 2000 as D 5550 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of
17、Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 The specific gravity value is used in many phase relationequations to determine relative volumes of particl
18、e, water, andgas mixtures.5.2 The term soil particle typically refers to a naturallyoccurring mineral grain that is not readily soluble in water.Therefore, the specific gravity of soils that contain extraneousmatter (such as cement, lime, and the like) or water-solublematerial (such as salt) must be
19、 corrected for the precipitate thatforms on the specimen after drying. If the precipitate has aspecific gravity less than the parent soil grains, the uncorrectedtest result will be too low. If the precipitate has a higherspecific gravity, then the uncorrected test value will be toohigh.NOTE 2Not wit
20、hstanding the statements on precision and bias con-tained in this test method: The precision of this test method is dependenton the competence of the personnel performing it and the suitability of theequipment and facilities used.Agencies which meet the criteria of PracticeD 3740 are generally consi
21、dered capable of competent testing. Users ofthis test method are cautioned that compliance with Practice D 3740 doesnot ensure reliable testing. Reliable testing depends on several factors;Practice D 3740 provides a means of evaluating some of those factors.6. Apparatus6.1 PycnometerThe gas pycnomet
22、er shall be one of thecommercially available models that determines the volume ofa solid by one of two methods. One measures the pressure dropthat occurs after a gas at a known pressure is allowed to flowinto another chamber (typically the first chamber contains thesolid material being tested). The
23、amount of pressure drop isrelated to the volume of soil present. The other type ofinstrument puts a known volume of gas into a chambercontaining the specimen. The increase in pressure is related tothe volume of the material. Either type of instrument isacceptable provided that the required accuracy
24、of the instru-ment produces a volume measurement that is 60.2 % of thespecimen volume.NOTE 3Commercially available instruments should be checked usingmaterials with known specific gravities to insure that they provideacceptable precision and accuracy for the range of soil types to be tested.Some ins
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD55502006STANDARDTESTMETHODFORSPECIFICGRAVITYOFSOILSOLIDSBYGASPYCNOMETER 气体 比重瓶 测定 土壤 固体 粒子 比重 标准

链接地址:http://www.mydoc123.com/p-520083.html