ASTM D5547-1995(2017) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf
《ASTM D5547-1995(2017) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5547-1995(2017) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5547 95 (Reapproved 2017)Standard Test Method forClay and Zeolite in Powdered Laundry Detergents by AtomicAbsorption1This standard is issued under the fixed designation D5547; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers atomic absorption tests appli-cable to powdered laundry detergents containi
3、ng clay andzeolite.21.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
4、 and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)43. Summary of Test Method3.1 The test sample
5、 is fused with lithium metaborate,dissolved in acid, its silicon and aluminum content measuredby atomic absorption, and the silicon/aluminum (Si/Al) ratiocalculated. The clay and zeolite content of the test sample iscalculated from the Si/Al ratio of the test sample and the Si/Alratio of the clay an
6、d zeolite expected in the test sample.4. Interferences4.1 Materials other than clay and zeolite that contain siliconor aluminum, or both, will interfere.5. Principle5.1 Clay and zeolite contain silicon and aluminum at differ-ent relative levels.5The silicon/aluminum ratio is then ameasure of the rel
7、ative level of clay and zeolite in detergentpowders. That is, detergent powders with a Si/Al ratio match-ing clay or zeolite contain only clay or zeolite, respectively.Detergent powders with Si/Al ratio falling between the Si/Alratio of clay and zeolite contain both clay and zeolite.5.2 This test me
8、thod is based on the linear relationshipbetween the relative composition (or ratio) of clay/zeolite indetergent powders and the Si/Al ratio of such detergents.5.3 A calibration equation is derivable, therefore, from justtwo experimental points: the Si/Al ratio of the zeolite standard(100 zeolite, 0
9、% clay) and the Si/Al ratio of the clay standard(0 % zeolite, 100 % clay).6. Apparatus6.1 Suitable Atomic Absorption Spectrophotometers, fittedwith a nitrous oxide-acetylene burner and aluminum andsilicon hollow cathode source lamps.6.2 Nitrous Oxide and Acetylene Tanks, with suitable regu-lators.6.
10、3 Muffle Furnace, capable of reaching 1000C.6.4 Analytical Balance.6.5 Fisher Burner or Equivalent.6.6 20-mL or Larger Platinum Crucibles.6.7 Platinum-tip Tongs.6.8 25-mL Buret.6.9 100-mL and 200-mL Polypropylene Volumetric Flasks.6.10 10-mL and 25-mL Graduated Cylinders.6.11 150-mL Plastic Beakers.
11、6.12 Magnetic Stirrer and Magnetic Stirring Bars.6.13 Blender, such as Waring6or Osterizer7or an industriallab model, or a mortar and pestle, if a blender is not available.1This test method is under the jurisdiction of ASTM Committee D12 on Soapsand Other Detergents and is the direct responsibility
12、of Subcommittee D12.12 onAnalysis and Specifications of Soaps, Synthetics, Detergents and their Components.Current edition approved Jan. 1, 2017. Published February 2017. Originallyapproved in 1994. Last previous edition approved in 2009 as D5547 95(2009).DOI: 10.1520/D5547-95R17.2Silicon and alumin
13、um measurements are by atomic absorption in this testmethod. ICP can be used to make such measurements as well.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the s
14、tandards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5The Si/Al ratio is usually about 1 in zeolites and about 3 in clays.6Waring blenders are available commercially.7Osterizer blenders are widely available commercially
15、.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of Inte
16、rnational Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.17. Reagents7.1 Purity of ReagentsReagents grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specific
17、ations of the Committee onAnalytical Reagents of the American Chemical Society, wheresuch specifications are available.8Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Pu
18、rity of WaterUnless otherwise indicated, referenceto water shall be understood to mean distilled water or water ofequal purity.7.3 Aluminum Standard, 1000 g Al/mL9or equivalent.7.4 Silicon Standard, 1000 g Si/mL.97.5 Potassium Chloride, Baker-analyzed reagent or equiva-lent.7.6 Potassium Chloride So
19、lution (1 %)Dissolve1gofpotassium chloride in 100 mL of distilled water. Mix well andstore in plastic container.7.7 Concentrated Hydrochloric Acid, Baker-analyzed re-agent or equivalent.7.8 Hydrochloric Acid Solution (1 + 1)Mix equal parts ofconcentrated HCl and distilled water by volume. Mix well a
20、ndstore in plastic container.7.9 Potassium Iodide, Baker-analyzed reagent or equiva-lent.7.10 Lithium Metaborate SPEX Grade, Special for Fu-sions.107.11 Zeolite StandardThe same material expected in thetest sample, to be used as standard.7.12 Clay StandardThe same material expected in the testsample
21、, to be used as standard.8. Instrumental Conditions8.1 Following the instrument manufacturers instructions,set up the atomic absorption instrument as follows:To measure Aluminum To measure SiliconWavelength, nm 309.3 251.6Range UV UVSlit, nm 0.2 0.2Flame Nitrous oxide-acetylene. Nitrous oxide-acetyl
22、ene.Rich, red. Strongly reducing red cone 23cm high with yellow outeredge.9. Procedure9.1 Determination of Aluminum:9.1.1 Accurately weigh 0.1 g (to the nearest 0.1 mg) ofzeolite standard (the same material expected in the test sample)into a clean, dry, platinum crucible. Also accurately weigh 0.2g
23、of clay standard (the same material expected in the testsample) into another clean, dry, platinum crucible.9.1.2 Grind a representative powdered detergent test samplein a blender to a fine, homogenous powder. (If a blender is notavailable, use a mortar and pestle).9.1.3 Accurately weigh 0.3 g (to th
24、e nearest 0.1 mg) of theground test sample(s) into still another clean, dry, platinumcrucible.9.1.4 Add2g(60.1 g) of lithium metaborate to eachplatinum crucible, and mix the contents with a plastic rod.9.1.5 Place the crucibles containing the mixtures in a coolmuffle furnace and turn on the heat. Wh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD554719952017STANDARDTESTMETHODFORCLAYANDZEOLITEINPOWDEREDLAUNDRYDETERGENTSBYATOMICABSORPTION 原子

链接地址:http://www.mydoc123.com/p-520079.html