ASTM D5547-1995(2003) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf
《ASTM D5547-1995(2003) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5547-1995(2003) Standard Test Method for Clay and Zeolite in Powdered Laundry Detergents by Atomic Absorption《原子吸收法测定粉未洗涤剂中的粘土和沸石的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5547 95 (Reapproved 2003)Standard Test Method forClay and Zeolite in Powdered Laundry Detergents by AtomicAbsorption1This standard is issued under the fixed designation D 5547; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers atomic absorption tests appli-cable to powdered laundry detergents conta
3、ining clay andzeolite.21.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practi
4、ces and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial Chemicals33. Summary of Test Method3.1 The test sample is fused with lithium metabo
5、rate,dissolved in acid, its silicon and aluminum content measuredby atomic absorption, and the silicon/aluminum (Si/Al) ratiocalculated. The clay and zeolite content of the test sample iscalculated from the Si/Al ratio of the test sample and the Si/Alratio of the clay and zeolite expected in the tes
6、t sample.4. Interferences4.1 Materials other than clay and zeolite that contain siliconor aluminum, or both, will interfere.5. Principle5.1 Clay and zeolite contain silicon and aluminum at differ-ent relative levels.4The silicon/aluminum ratio is then ameasure of the relative level of clay and zeoli
7、te in detergentpowders. That is, detergent powders with a Si/Al ratio match-ing clay or zeolite contain only clay or zeolite, respectively.Detergent powders with Si/Al ratio falling between the Si/Alratio of clay and zeolite contain both clay and zeolite.5.2 This test method is based on the linear r
8、elationshipbetween the relative composition (or ratio) of clay/zeolite indetergent powders and the Si/Al ratio of such detergents.5.3 A calibration equation is derivable, therefore, from justtwo experimental points: the Si/Al ratio of the zeolite standard(100 zeolite, 0 % clay) and the Si/Al ratio o
9、f the clay standard(0 % zeolite, 100 % clay).6. Apparatus6.1 Suitable Atomic Absorption Spectrophotometers, fittedwith a nitrous oxide-acetylene burner and aluminum andsilicon hollow cathode source lamps.6.2 Nitrous Oxide and Acetylene Tanks, with suitable regu-lators.6.3 Muffle Furnace, capable of
10、reaching 1000C.6.4 Analytical Balance.6.5 Fisher Burner or Equivalent.6.6 20-mL or Larger Platinum Crucibles.6.7 Platinum-tip Tongs.6.8 25-mL Buret.6.9 100-mL and 200-mL Polypropylene Volumetric Flasks.6.10 10-mL and 25-mL Graduated Cylinders.6.11 150-mL Plastic Beakers.6.12 Magnetic Stirrer and Mag
11、netic Stirring Bars.6.13 Blender, such as Waring5or Osterizer6or an industriallab model, or a mortar and pestle, if a blender is not available.7. Reagents7.1 Purity of ReagentsReagents grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to t
12、he specifications of the Committee onAnalytical Reagents of the American Chemical Society, where1This test method is under the jurisdiction of ASTM Committee D12 on Soapsand Other Detergents and is the direct responsibility of Subcommittee D12.12 onAnalysis of Soaps and Synthetic Detergents.Current
13、edition approved April 15, 1995. Published June 1995. Originallypublished as D 5547 94. Last previous edition D 5547 94.2Silicon and aluminum measurements are by atomic absorption in this testmethod. ICP can be used to make such measurements as well.3Annual Book of ASTM Standards, Vol 15.05.4The Si/
14、Al ratio is usually about 1 in zeolites and about 3 in clays.5Waring blenders are available commercially.6Osterizer blenders are widely available commercially.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.such specifications are av
15、ailable.7Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean distilled water or water
16、 ofequal purity.7.3 Aluminum Standard, 1000 g Al/mL8or equivalent.7.4 Silicon Standard, 1000 g Si/mL.87.5 Potassium Chloride, Baker-analyzed reagent or equiva-lent.7.6 Potassium Chloride Solution (1 %)Dissolve1gofpotassium chloride in 100 mL of distilled water. Mix well andstore in plastic container
17、.7.7 Concentrated Hydrochloric Acid, Baker-analyzed re-agent or equivalent.7.8 Hydrochloric Acid Solution (1 + 1)Mix equal parts ofconcentrated HCl and distilled water by volume. Mix well andstore in plastic container.7.9 Potassium Iodide, Baker-analyzed reagent or equiva-lent.7.10 Lithium Metaborat
18、e SPEX Grade, Special for Fu-sions9.7.11 Zeolite StandardThe same material expected in thetest sample, to be used as standard.7.12 Clay StandardThe same material expected in the testsample, to be used as standard.8. Instrumental Conditions8.1 Following the instrument manufacturers instructions,set u
19、p the atomic absorption instrument as follows:To measure Aluminum To measure SiliconWavelength, nm 309.3 251.6Range UV UVSlit, nm 0.2 0.2Flame Nitrous oxide-acetylene. Nitrous oxide-acetylene.Rich, red. Strongly reducing red cone 23cm high with yellow outeredge.9. Procedure9.1 Determination of Alumi
20、num:9.1.1 Accurately weigh 0.1 g (to the nearest 0.1 mg) ofzeolite standard (the same material expected in the test sample)into a clean, dry, platinum crucible. Also accurately weigh 0.2g of clay standard (the same material expected in the testsample) into another clean, dry, platinum crucible.9.1.2
21、 Grind a representative powdered detergent test samplein a blender to a fine, homogenous powder. (If a blender is notavailable, use a mortar and pestle).9.1.3 Accurately weigh 0.3 g (to the nearest 0.1 mg) of theground test sample(s) into still another clean, dry, platinumcrucible.9.1.4 Add2g(60.1 g
22、) of lithium metaborate to eachplatinum crucible, and mix the contents with a plastic rod.9.1.5 Place the crucibles containing the mixtures in a coolmuffle furnace and turn on the heat. When the temperaturereaches 1000C, maintain heat for at least 5 additional min.NOTE 1The sample will ignite and sp
23、latter if placed in a hot furnace.If it is not possible to start with a cool furnace, gently char the sample witha Fisher burner first, avoiding ignition, then place in the furnace.9.1.6 Place 90 mL of distilled water into 150-mL plasticbeakers. (Use as many beakers as there are standards andsamples
24、).9.1.7 Add a magnetic stirring bar to each beaker, and placeon a magnetic stirrer. Mix rapidly to make the water swirl inthe beaker, but do not allow anything to splash out. Thisapparatus should be near the furnace containing the ashedstandards and sample(s).9.1.8 Using platinum-tip tongs, remove o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD554719952003STANDARDTESTMETHODFORCLAYANDZEOLITEINPOWDEREDLAUNDRYDETERGENTSBYATOMICABSORPTION 原子

链接地址:http://www.mydoc123.com/p-520077.html