ASTM D5508-2016 Standard Test Method for Determination of Residual Acrylonitrile Monomer in Styrene-Acrylonitrile Copolymer Resins and Nitrile-Butadiene Rubber by Headspace-Capilla.pdf
《ASTM D5508-2016 Standard Test Method for Determination of Residual Acrylonitrile Monomer in Styrene-Acrylonitrile Copolymer Resins and Nitrile-Butadiene Rubber by Headspace-Capilla.pdf》由会员分享,可在线阅读,更多相关《ASTM D5508-2016 Standard Test Method for Determination of Residual Acrylonitrile Monomer in Styrene-Acrylonitrile Copolymer Resins and Nitrile-Butadiene Rubber by Headspace-Capilla.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5508 16Standard Test Method forDetermination of Residual Acrylonitrile Monomer in Styrene-Acrylonitrile Copolymer Resins and Nitrile-ButadieneRubber by Headspace-Capillary Gas Chromatography (HS-CGC)1This standard is issued under the fixed designation D5508; the number immediately foll
2、owing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test metho
3、d covers the determination of the re-sidual acrylonitrile (RAN) content in nitrile-butadiene rubbers(NBR), styrene-acrylonitrile (SAN) copolymers, and rubber-modified acrylonitrile-butadiene-styrene (ABS) resins.1.2 Any components that can generate acrylonitrile in theheadspace procedure will consti
4、tute an interference. The pres-ence of 3-hydroxypropionitrile in latices limits this procedureto dry rubbers and resins.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of the
5、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in 6.3 and 6.4.NOTE 1Ther
6、e is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Summary of Test Method3.1 Two dispersions (in o-dichlorobenzene) are preparedand sealed in headspace vials for e
7、ach polymer; one vialcontains the polymer in solvent while the second vial containsthe polymer, solvent, plus a known standard addition ofacrylonitrile (AN). Both vials are agitated for a specified timeunder ambient conditions. After agitation, the vials are ther-mally equilibrated in a constant-tem
8、perature bath.3.2 After completion of the timed equilibration, an aliquotof the heated headspace gas from each vial is injected into acapillary gas-chromatographic column using an automatedinjection system. The capillary column will provide the chro-matographic resolution necessary to isolate the AN
9、 from othervolatiles potentially present. The AN response is measuredusing a nitrogen-specific detector (NPD). The raw data signalis converted to a relative RAN concentration through astandard addition calculation.4. Significance and Use4.1 A measurement of the residual acrylonitrile in nitrilerubbe
10、rs (NBR), styrene-acrylonitrile copolymers or ABS ter-polymers will determine the polymers suitability for variousapplications.4.2 Under optimum conditions, the minimum level of de-tection of RAN in NBR, SAN, or ABS terpolymers is approxi-mately 50 ppb.5. Apparatus5.1 Gas Chromatograph, equipped wit
11、h a nitrogen-phosphorus specific detector, backflush valve (see Fig. 1), splitinjector, and capable of accepting megabore (0.53 mm insidediameter) fused silica capillary columns. Detector make-up gasis required.NOTE 2The use of a backflush configuration will provide foroperating advantages, but its
12、use is optional. Chlorinated solvents quenchthe alkali bead in a nitrogen-phosphorous detector, producing a loss ofsignal. While the bead (signal) will recover as the solvent evacuates thedetector, repeated quenching during a multi-run sequence may produceinstabilities in the signal (and precision)
13、over the sequence period.5.2 Automated Headspace Sampler, shall have a thermost-atted sample tray capable of 90C heating with constantheating times.Automated sampling of the headspace gas in thesample vials via a heated, constant-volume sample loop or1This test method is under the jurisdiction ofAST
14、M Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods andSection D20.70.02 on Chromatography.Current edition approved Sept. 1, 2016. Published September 2016. Originallyapproved in 1994. Last previous edition approved in 2009 as D5508 - 94a(2009)1.D
15、OI: 10.1520/D5508-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at
16、 the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1pressure balancing sampling mechanism is required. Conductsampling to the gas chromatograph by means of a heatedtransfer line of minimum dead volume.5.3 Fused Si
17、lica Porous-Layer-Open-Tubular (PLOT) Cap-illary Column, 30 m 0.53 mm inside diameter.NOTE 3The column should be cut so as to havea3msection for thepre-column (Column 1) and a 27-m section for the analytical column(Column 2).5.4 Variable Restrictor.5.5 Data-Recording DeviceA strip-chart recorder, re
18、cord-ing integrator, or computer-based data system is suitable.5.6 Wrist-Action Shaker.5.7 Analytical Balance, 0.1-mg readability.5.8 Headspace Vials, 20-mL capacity.5.9 Aluminum Crimp Caps, 20-mm diameter.5.10 Septa, TFE-fluorocarbon-faced silicone construction,20-mm diameter.5.11 Crimper, for 20-m
19、m crimp caps.6. Reagents and Materials6.1 Purity of ReagentsChemicals of the highest purityshall be used in all tests. Solvents shall have a minimum ofvolatile impurities. Other grades shall only be used afterascertaining that the reagent is free of interferences.6.2 Observe all health and safety re
20、commendations for eachchemical, as prescribed by the manufacturer.6.3 Acrylonitrile, 99+%. (WarningAcrylonitrile is anOSHA-regulated carcinogen and should not be released intothe laboratory atmosphere. All work involving acrylonitrileshould be carried out in a hood or with proper personalprotection
21、to minimize human exposure.)6.4 o-Dichlorobenzene. (Warningo-Dichlorobenzene ismoderately toxic and should only be handled in a hood or withproper personal protection to limit human exposure.)NOTE 4Each lot of o-dichlorobenzene should be analyzed under thesame instrumental conditions as the NBR samp
22、les to ensure that impuri-ties are not present that will interfere with the acrylonitrile peak.7. Sampling and Storage7.1 The polymer test unit (sample) submitted for analysisshall be supplied in the form of a 134 in. (45 mm) cube.7.2 All test specimens shall be taken from the interior of thepolymer
23、-test unit to minimize the contribution of surfaceeffects on the residual-acrylonitrile level.7.3 Keep all polymer-test units in sealed containers. Ana-lyze test-specimen solutions immediately after preparation.Report any analysis delays along with the test results.8. Calibration8.1 Preparation of E
24、xternal Standard Solutions:8.1.1 Tare (to the nearest 0.1 mg) a 25-mL volumetric flaskcontaining 10 mL of o-dichlorobenzene (DCB).8.1.2 Weigh (to the nearest 0.1 mg) into the 25-mL volu-metric flask 40 6 5 mg of AN. Dilute to the mark with DCB.Label this solution as the “external-standard master sol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD55082016STANDARDTESTMETHODFORDETERMINATIONOFRESIDUALACRYLONITRILEMONOMERINSTYRENEACRYLONITRILECOPOLYMERRESINSANDNITRILEBUTADIENERUBBERBYHEADSPACECAPILLAPDF

链接地址:http://www.mydoc123.com/p-519991.html