ASTM D5337-2011(2016) Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps《个人取样泵流量调节的标准实施规程》.pdf
《ASTM D5337-2011(2016) Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps《个人取样泵流量调节的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5337-2011(2016) Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps《个人取样泵流量调节的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5337 11 (Reapproved 2016)Standard Practice forFlow Rate Adjustment of Personal Sampling Pumps1This standard is issued under the fixed designation D5337; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the calibration of samplingpumps commonly used for monitoring personal airborne ex-posures in the
3、work-place.1.2 This practice includes procedures for describing primaryand secondary calibration techniques.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety conce
4、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling a
5、nd Analysis ofAtmospheres2.2 NIOSH and OSHA Documents:HSM-99-71-31 Personal Sampling Pump for CharcoalTubes; Final Report3NIOSH Manual of Analytical Methods, 4thed.4OSHA Analytical Methods Manual53. Terminology3.1 For definitions of terms used in this practice, refer toTerminology D1356.3.2 The term
6、 primary flow-rate calibration, as used in thispractice, does not imply the calibration is traceable to aprimary standard, unless the apparatus used in the calibration(burets, stop-watches, etc.) has been demonstrated to betraceable to national or international standards, and that thistraceability i
7、s established on a routine (generally annual) basis.Traceability of calibration is strongly recommended.4. Summary of Practice4.1 Abubble tube meter or electronic near-frictionless pumpis used for primary calibration of personal sampling pumps.The practice is applicable to systems using air sampling
8、devices. Provisions are made for both manual and automatedbubble meters.4.2 Secondary calibration procedures for field applicationsare also included in the practice (see 7.3).5. Significance and Use5.1 Most occupational exposure assessment methods re-quire the use of personal sampling pumps to colle
9、ct air samplesat typical workplace sampling rates, with sampling volumesspecified by (a) particular procedure(s). The precision and biasof these methods are directly affected by the precision and biasof the pumps used to measure the air volume(s) sampled.6. Apparatus6.1 Burets, 1-L (for high flow) a
10、nd 100-mL or 10 mL (forlow flow).6.2 Manometer.6.3 Rotameter.6.4 Stop Watch.6.5 Electronic Bubble Meter or Near-frictionless PistonFlowmeter (alternates), should have traceable calibration (see3.2).7. Procedure7.1 Calibrate the personal sampling pumps before andmeasure after each days sampling.7.2 P
11、rimary Flow-Rate Calibration Device(s) (as noted in3.2, these are not primary standards unless the apparatus usedin the calibration has been demonstrated to be traceable tonational and international standards):1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the di
12、rect responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved Nov. 1, 2016. Published November 2016. Originallyapproved in 1992. Last previous edition approved in 2011 as D5337 11. DOI:10.1520/D5337-11R16.2For referenced ASTM standards, visit the ASTM website, www.astm
13、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the U.S. Department of Commerce, National Technical Infor-mation Service, Port Royal Road, Springfield, VA 22
14、161.4Centers for Disease Control and Prevention (CDC), National Institute forOccupational Safety and Health (NIOSH), Cincinnati, Ohio (1994); Available fromNIOSH Publications, 4676 Columbia Parkway, Cincinnati, Ohio 45226;www.cdc.gov/niosh/nmam.5Occupational Safety and Health Administration, Salt La
15、ke Technical Center,Salt Lake City, Utah (1985); Available from OSHA Analytical Laboratory, 8660 S.Sandy Parkway, Sandy, UT 84070; www.osha.gov/dts/sltc/methods.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.2.1 Bubble Meter Method
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD533720112016STANDARDPRACTICEFORFLOWRATEADJUSTMENTOFPERSONALSAMPLINGPUMPS 个人 取样 流量 调节 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-519512.html