ASTM D5315-2004 Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization《.pdf
《ASTM D5315-2004 Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization《.pdf》由会员分享,可在线阅读,更多相关《ASTM D5315-2004 Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization《.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5315 04Standard Test Method forDetermination of N-Methyl-Carbamoyloximes andN-Methylcarbamates in Water by Direct Aqueous InjectionHPLC with Post-Column Derivatization1This standard is issued under the fixed designation D 5315; the number immediately following the designation indicate
2、s the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This is a high-performance liquid chromatogra
3、phic(HPLC) test method applicable to the determination of certainn-methylcarbamoyloximes and n-methylcarbamates in groundwater and finished drinking water (1)2. This test method isapplicable to any carbamate analyte that can be hydrolyzed toa primary amine. The following compounds have been vali-dat
4、ed using this test method:AnalyteChemical Abstract ServicesRegistry NumberAAldicarb 116-06-3Aldicarb sulfone 1646-88-4Aldicarb sulfoxide 1646-87-3Baygon 114-26-1Carbaryl 63-25-2Carbofuran 1563-66-23-Hydroxycarbofuran 16655-82-6Methiocarb 2032-65-7Methomyl 16752-77-5Oxamyl 23135-22-0_ANumbering syste
5、m of Chemical Abstracts, Inc.1.2 This test method has been validated in a collaborativeround-robin study (2) and estimated detection limits (EDLs)have been determined for the analytes listed in 1.1 (Table 1).Observed detection limits may vary between ground waters,depending on the nature of interfer
6、ences in the sample matrixand the specific instrumentation used.1.3 This test method is restricted to use by, or under thesupervision of, analysts experienced in both the use of liquidchromatography and the interpretation of liquid chromato-grams. Each analyst should demonstrate an ability to genera
7、teacceptable results with this test method using the proceduredescribed in 12.3.1.4 When this test method is used to analyze unfamiliarsamples for any or all of the analytes listed in 1.1, analyteidentifications should be confirmed by at least one additionalqualitative technique.1.5 The values state
8、d in SI units are to be regarded as thestandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of reg
9、ulatory limitations prior to use. Additional guid-ance on laboratory safety is available and suitable referencesfor the information are provided (3-5).2. Referenced Documents2.1 ASTM Standards:3D 1129 Terminology Relating to WaterD 1192 Specification for Equipment for Sampling Waterand Steam in Clos
10、ed Conduits4D 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Closed Conduits1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct
11、responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 1, 2004. Published June 2004. Originallyapproved in 1992. Last previous edition approved in 1998 as D 5315 92 (1998).2The boldface numbers in parentheses refer to the references
12、at the end of thistest method.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.TABLE 1 Relative Ret
13、ention Times for the Primary andConfirmation Columns and EDLs for the 10 CarbamatePesticidesAnalyteRetention Time (minutes)PrimaryAConfirmationBEDLCAldicarb 27.0 21.4 1.0Aldicarb sulfone 15.2 12.2 2.0Aldicarb sulfoxide 15.0 17.5 2.0Baygon (Propoxur) 29.6 23.4 1.0Carbaryl 30.8 25.4 2.0Carbofuran 29.3
14、 24.4 1.53-Hydroxycarbofuran 23.3 19.0 2.0Methiocarb 34.9 28.6 4.0Methomyl 18.4 14.8 0.50Oxamyl 17.4 14.6 2.0APrimary column250 by 4.6 mm inside diameter Altex Ultrasphere ODS, 5m.BConfirmation column250 by 4.6 mm inside diameter Supelco LC-1, 5 m.CEstimated method detection limit in micrograms per
15、litre.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D 3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsE 682 Practice for Liquid Chromatography Terms and Re-lationships2.2 U.S. Environm
16、ental Protection Agency Standard:EPA Method 531.1, Revision 3.0, USEPA, EMSL-Cincinnati, 19895EPA Method 531.2, Revision 1.0, USEPA, EMSL-Cincinnati, 200163. Terminology3.1 DefinitionsFor definitions of water terms used in thistest method, refer to Terminology D 1129. For definitions ofother terms u
17、sed in this test method, refer to Practice E 682.3.2 Definitions of Terms Specific to This Standard:3.2.1 calibration standard (CAL)a solution preparedfrom the primary dilution standard solution and stock standardsolutions of the internal standards and surrogate analytes. CALsolutions are used to ca
18、librate the instrument response withrespect to analyte concentration.3.2.2 field duplicates (FD1 and FD2)two separatesamples collected at the same time, placed under identicalcircumstances, and treated exactly the same throughout fieldand laboratory procedures. Analyses of FD1 and FD2 providea measu
19、re of the precision associated with sample collection,preservation, and storage, as well as with laboratory proce-dures.3.2.3 field reagent blank (FRB)reagent water placed in asample container in the laboratory and treated in all respects asa sample, including being exposed to sampling site conditio
20、ns,storage, preservation, and all analytical procedures. The pur-pose of the FRB is to determine whether method analytes orother interferences are present in the field environment.3.2.4 internal standarda pure analyte(s) added to a solu-tion in known amount(s) and used to measure the relativerespons
21、es of other analytes and surrogates that are componentsof the same solution. The internal standard must be an analytethat is not a sample component.3.2.5 laboratory duplicates (LD1 and LD2)two samplealiquots taken in the analytical laboratory and analyzed sepa-rately with identical procedures. Analy
22、ses of LD1 and LD2provide a measure of the precision associated with laboratoryprocedures, but not with sample collection, preservation, orstorage procedures.3.2.6 laboratory-fortified blank (LFB)an aliquot of re-agent water to which known quantities of the test methodanalytes are added in the labor
23、atory. The LFB is analyzedexactly as a sample is; its purpose is to determine whether themethodology is in control and whether the laboratory iscapable of making accurate and precise methods at the requiredtest method detection limit.3.2.7 laboratory-fortified sample matrix (LFM)an aliquotof an envi
24、ronmental sample to which known quantities of thetest method analytes are added in the laboratory. The LFM isanalyzed exactly as a sample is; its purpose is to determinewhether the sample matrix contributes bias to the analyticalresults. The background concentrations of the analytes in thesample mat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53152004STANDARDTESTMETHODFORDETERMINATIONOFNMETHYLCARBAMOYLOXIMESANDNMETHYLCARBAMATESINWATERBYDIRECTAQUEOUSINJECTIONHPLCWITHPOSTCOLUMNDERIVATIZATIONPDF

链接地址:http://www.mydoc123.com/p-519453.html