ASTM D5018-1989(2015)e1 Standard Test Method for Shear Viscosity of Coal-Tar and Petroleum Pitches《煤焦油和石油沥青的剪切粘度的标准试验方法》.pdf
《ASTM D5018-1989(2015)e1 Standard Test Method for Shear Viscosity of Coal-Tar and Petroleum Pitches《煤焦油和石油沥青的剪切粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5018-1989(2015)e1 Standard Test Method for Shear Viscosity of Coal-Tar and Petroleum Pitches《煤焦油和石油沥青的剪切粘度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5018 89 (Reapproved 2015)1Standard Test Method forShear Viscosity of Coal-Tar and Petroleum Pitches1This standard is issued under the fixed designation D5018; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTESI units formatting was corrected editorially in May 2015.1. Scope1.1 This test method covers the determination of the appa
3、r-ent shear viscosity of coal-tar and petroleum-based pitcheshaving a Mettler softening point (SP) range of approximately95 C to 120 C.1.2 This test method is applicable only for rotational vis-cometers.1.3 Since this test method is based on theoretical grounds,strict adherence to details of the pro
4、cedure is necessary tocomply with the theoretical requirements.1.4 The values stated in SI units are to be regarded asstandard.1.4.1 ExceptionThe values stated in conventional units(centipoise) are to be regarded as the standard for viscositymeasurement only. The SI unit is the pascal second (Pas) a
5、ndone millipascal second (mPas) = one centipoise (cps); centi-poise is in cgs units.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
6、 determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2D4296 Practice for Sampling PitchE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Summar
7、y of Test Method3.1 The viscosity of a pitch, over the temperature range ofabout 40 C to 100 C above the SP of the material, isdetermined using a rotational viscometer.3.2 The recommended specifications herein are for measur-ing the apparent shear viscosity of binder pitches via aconcentric cylinder
8、 viscometer. Apparent shear viscosity is theratio of shear stress to shear rate in a unidirectional simpleshear flow field at steady state conditions. A concentriccylinder viscometer is useful for measuring the apparent shearviscosity, provided the sample temperature is adequatelycontrolled, the “en
9、d-effects” are negligible, and the gap be-tween rotor/cup is small and remains constant during the test.The extrapolated value of apparent shear viscosity at “zero”shear rate is called shear viscosity.4. Significance and Use4.1 This test method is useful as one element in establishingthe uniformity
10、of shipments.4.2 Viscosity is also valuable for rheological characteriza-tion of binder pitches. Binder pitch imparts consistency to1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.
11、05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved April 1, 2015. Published May 2015. Originallyapproved in 1989. Last previous edition approved in 2009 as D5018 89 (2009).DOI: 10.1520/D5018-89R15E01.2For referenced ASTM standards, visit the ASTM website, www.astm
12、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1carbonaceou
13、s mixes and affects their resistance to deformation.Binder pitch viscosity is important for assessing mix consis-tency and for evaluating the ease of mix extrusion or moldinginto artifacts.5. Apparatus5.1 ViscometerArotational viscometer capable of measur-ing viscosity in the range of about 5 cps to
14、 15 000 cps; theviscometer should be equipped with the appropriate accesso-ries to allow measurements up to about 230 C. Two viscom-eters meeting these requirements are the LVT, LVF,3orequivalent, and the RV100, RV20,4or equivalent.5.2 Sample Temperature Control System Any device ca-pable of maintai
15、ning the sample test temperature within limitsof 61.0 C while allowing viscosity measurements. Examplesare the Thermosel System3and the TP 245with heater.5.3 ThermometerASTM precision thermometer 2C, hav-ing a range of 5 C to 300 C.5.4 Hot Plate5Any hot plate with adjustable temperaturecontrol and s
16、urface temperature indication (to prevent sampleoverheating).5.5 Calibration Fluids6A series of calibrated fluids thatcover the viscosity range of approximately 100 cps to15 000 cps at temperatures up to 150 C.6. Reagents and Materials6.1 Cleaning SolventAny solvent capable of dissolvingpitch, (suit
17、able solvents are quinoline or creosote oils).6.2 Rinsing SolventsToluene and acetone are used forfinal rinsing after initial cleaning.7. Safety Hazards7.1 Fumes of hot pitch or solvents, or both, should beremoved from all working areas by means of proper hoods.Theworking area should be kept free of
18、 sparks and flames.Quinoline fumes should not be inhaled, and prolonged contactwith skin should be avoided. Toluene is toxic and flammable.8. Bulk Sampling8.1 Take samples from shipments in accordance with Prac-tice D4296. Samples shall be free of foreign substances.Thoroughly mix the sample immedia
19、tely before removing arepresentative portion for the determination or for dehydration.9. Sample Preparation9.1 Ensure sample is dry; if there is visible moisture,dehydrate at 50 C in a forced-air or vacuum oven until dry, butno longer than 2 h. (Experience has shown that drying attemperatures in exc
20、ess of 50 C increases the SP and viscosityof the pitch.)9.2 Crush dry lumps of pitch to a size of 6 mm to 12 mm.10. Charging Sample Cup10.1 In a suitable container, or the sample cup, melt pitchwith occasional stirring. Overheating of sample must beavoided as loss of volatiles may affect viscosity.
21、(Maximumtemperature should not exceed 50 C above SP.As a guide, thesurface temperature of the hot plate surface should not exceed200 C.)10.2 Place rotor in cup and preheat both to approximatelythe first test temperature.10.3 Remove rotor and transfer required amount of pitch tothe level specified by
22、 the manufacturer.10.4 Re-insert rotor, check that rotor is immersed to speci-fied depth, and install insulating cover.11. Viscometer Calibration11.1 This step, required only occasionally, is designed toestablish that the temperature and viscosity indicated by theappropriate measuring devices are in
23、 agreement with knownstandards.11.2 Equipment is to be properly leveled and installed inaccordance with manufacturers instructions.11.3 Use the ASTM thermometer (applying the appropriatestem correction) to correlate pitch temperature (in cup) totemperature controller/indicator.Test temperature is co
24、nsideredto be the actual pitch temperature and not the temperatureindicated on the controller.11.4 Calibrate viscometer using calibration fluids.11.4.1 Use high- and low-temperature fluids; see 5.5.11.4.2 Calibrate each rotor/cup combination and use themas a paired set.12. Procedure for Viscosity De
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD501819892015E1STANDARDTESTMETHODFORSHEARVISCOSITYOFCOALTARANDPETROLEUMPITCHES 煤焦油 石油 沥青 剪切 粘度 标准

链接地址:http://www.mydoc123.com/p-518670.html