《ASTM D4993-2008 Standard Practice for Calculation and Adjustment of Silica (SiO2) Scaling for Reverse Osmosis《为反向渗透标定二氧化硅的计算和校正的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4993-2008 Standard Practice for Calculation and Adjustment of Silica (SiO2) Scaling for Reverse Osmosis《为反向渗透标定二氧化硅的计算和校正的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4993 08Standard Practice forCalculation and Adjustment of Silica (SiO2) Scaling forReverse Osmosis1This standard is issued under the fixed designation D 4993; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calculation and adjustment ofsilica (SiO2) for the concentrate stream of a reverse osmosi
3、ssystem. The calculations are used to determine the need forscale control in the operation and design of reverse osmosisinstallations. This practice is applicable for all types of reverseosmosis devices (tubular, spiral wound, and hollow fiber).1.2 This practice is applicable to both brackish waters
4、 andseawaters.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
5、establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 859 Test Method for Silica in WaterD 1067 Test Methods for Acidity or Alkalinity of WaterD 1129 Terminology Relating to WaterD 1293 T
6、est Methods for pH of WaterD 3739 Practice for Calculation and Adjustment of theLangelier Saturation Index for Reverse OsmosisD 4194 Test Methods for Operating Characteristics of Re-verse Osmosis and Nanofiltration DevicesD 6161 Terminology Used for Microfiltration, Ultrafiltra-tion, Nanofiltration
7、and Reverse Osmosis Membrane Pro-cesses3. Terminology3.1 For definitions of terms relating to water used in thispractice, refer to Terminology D 1129 and D 6161.4. Summary of Practice4.1 This practice consists of calculating the potential forscaling by SiO2in a reverse osmosis concentrate stream fro
8、mthe concentration of SiO2in the feed solution and the recoveryof the reverse osmosis system.4.2 This practice also presents techniques to eliminatescaling by decreasing the recovery, decreasing the SiO2con-centration in the feedwater, adjusting the pH of the feedwater,and increasing the temperature
9、 of the feedwater.5. Significance and Use5.1 In the design and operation of reverse osmosis installa-tions, it is important to predict the SiO2scaling properties ofthe concentrate stream. Because of the increase in the concen-tration of SiO2and the change in pH, the scaling property ofthe concentrat
10、e stream will be quite different from that of thefeed solution. This practice permits the calculation of thescaling potential for the concentrate stream from the feedwateranalysis and the reverse osmosis operating parameters.5.2 Scaling by SiO2will adversely affect the reverse osmo-sis performance.
11、This practice gives various procedures for theprevention of scaling.5.3 The presence of certain metals, for example, Al+3, maysignificantly alter the solubility of SiO2via formation ofinsoluble metal silicates. This practice does not address thisphenomena.6. Procedure6.1 Determine the concentration
12、of SiO2in the feed streamin accordance with Test Method D 859.6.2 Measure the temperature of the feed solution.6.3 Measure the pH of the feed solution using Test MethodsD 1293.NOTE 1If acid is used for control of CaCO3scale, measure the pHafter acid addition.6.4 Determine the total alkalinity of the
13、 feed solution usingTest Methods D 1067 and express as CaCO3.NOTE 2If acid is used for control of calcium carbonate (CaCO3)scale, determine the total alkalinity after acid addition.1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee
14、 D19.08 on Membranes and IonExchange Materials.Current edition approved May 1, 2008. Published May 2008. Originallyapproved in 1989. Last previous edition approved in 2003 as D 4993 89 (2003).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
15、States.7. Calculation7.1 Calculate the SiO2concentration in the concentratestream from the SiO2concentration in the feed solution, therecovery of the reverse osmosis system, and the SiO2passageas follows:SiO2c5 SiO2f31 2 YSPSiO2!1 2 Ywhere:SiO2c= silica concentration in concentrate as SiO2,mg/L,SiO2
16、f= silica concentration in feed as SiO2, mg/L,Y = recovery of the reverse osmosis system, ex-pressed as a decimal, andSPSiO2= silica passage, expressed as a decimal.NOTE 3SPSiO2can be obtained from the supplier of the reverseosmosis system.7.2 Calculate the pH of the concentrate stream from the pHof
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD49932008STANDARDPRACTICEFORCALCULATIONANDADJUSTMENTOFSILICASIO2SCALINGFORREVERSEOSMOSIS 反向 渗透 标定

链接地址:http://www.mydoc123.com/p-518604.html