《ASTM D4913-2000(2011) Standard Practice for Determining Concentration of Hydrogen Sulfide by Direct Reading Length of Stain Visual Chemical Detectors《用直读法 污染程度 可见化学检测器测定硫化氢的浓度的标准操作.pdf》由会员分享,可在线阅读,更多相关《ASTM D4913-2000(2011) Standard Practice for Determining Concentration of Hydrogen Sulfide by Direct Reading Length of Stain Visual Chemical Detectors《用直读法 污染程度 可见化学检测器测定硫化氢的浓度的标准操作.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4913 00 (Reapproved 2011)Standard Practice forDetermining Concentration of Hydrogen Sulfide by DirectReading, Length of Stain, Visual Chemical Detectors1This standard is issued under the fixed designation D4913; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the detection of hydrogen sulfidegas by vi
3、sual chemical detectors. Included under visual chemi-cal detectors are: short-term detector tubes (1),2long-termdetector tubes (2), and length-of-stain dosimeters (3). Diffusiontubes are not included under this practice because they are notdirect reading, and spot tests are not included because of t
4、heirpoor accuracy. The sample results are immediately available byvisual observation, thus no analytical equipment is needed.1.2 This practice reflects the current state-of-the-art forcommercially available visual length-of-stain detectors forhydrogen sulfide. Any mention of a specific manufacturer
5、inthe text or references does not constitute an endorsement byASTM.1.3 The values stated in SI units are to be regarded asstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establi
6、sh appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD3686 Practice for Sampling Atmospheres to Collect Or-ganic Compound Vapors
7、(Activated Charcoal Tube Ad-sorption Method)D4490 Practice for Measuring the Concentration of ToxicGases or Vapors Using Detector TubesD4599 Practice for Measuring the Concentration of ToxicGases or Vapors Using Length-of-Stain Dosimeters2.2 Other Documents:CFR 1910.1000 Federal Occupational Safety
8、and HealthStandard Title 29, Part 1910.1000, Subpart Z, and Part1926.55, Subpart D4NIOSH Criteria for a Recommended Standard, Occupa-tional Exposure to Hydrogen Sulfide, 19775Threshold Limit Values for Chemical Substances in theWork Environment Adopted by the American Conferenceof Governmental Indus
9、trial Hygienists, latest issue62.3 ANSI Standard:ANSI/ISEA 1021990(R1998) Gas Detector Tube Units-Short-Term Type for Toxic Gases and Vapors in WorkingEnvironments73. Terminology3.1 DefinitionsFor definitions of terms used in thismethod, refer to Terminology D1356.4. Summary of Practice4.1 In genera
10、l, the length-of-stain visual detectors describedin this practice consist of a sealed glass tube filled with areactive chemical dispersed on a granular material or a paperstrip. This reactive material is sensitive to hydrogen sulfide andchanges color upon exposure to hydrogen sulfide gas. Thesedetec
11、tors are designed so that the length of the color change inthe tube is related to the concentration of hydrogen sulfideunder conditions of sampling volume or sampling time speci-fied by the manufacturer. These detectors are typically cali-brated by the manufacturer on an individual lot basis. Threeg
12、eneral types of detectors are in current use.1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved March 1, 2011. Published March 2011. Originallyapproved in 1989. Last pr
13、evious edition approved in 2005 as D4913 - 051. DOI:10.1520/D4913-00R11.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard practice.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
14、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Code of Federal Regulations, available from the U.S. Government PrintingOffice Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE,Washington, DC 20401.5Available from
15、 National Technical Information Service (NTIS), 5285 PortRoyal Rd., Springfield, VA 22161, http:/www.ntis.gov.6Available from American Conference of Governmental Industrial Hygienists,Inc. (ACGIH), 1330 Kemper Meadow Dr., Cincinnati, OH 45240, http:/www.acgih.org.7Available from American National St
16、andards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.1 Short-Term Detector TubesA given volume of air(specified by the manufacturer) is pulled
17、through the tube by apump in a time period on the order of 1 to 10 min. Thelength-of-stain is related to the amount of air sampled and thehydrogen sulfide concentration during the sample period.4.1.2 Long-Term Detector TubesThe air sample is pulledthrough the tube at a slower, constant flow rate (sp
18、ecified bythe manufacturer) by an electrical pump over a 1- to 8-h timeperiod. The length of color change and the sampling time areused to estimate the time weighted average (TWA) concentra-tion of hydrogen sulfide.4.1.3 Length-of-Stain Dosimeter TubesThis detector typesamples the atmosphere to be t
19、ested by diffusion; no pump isrequired. Sampling times are on the order of 1 to 8 h and thestain length as a function of sampling time is related to theTWA concentration of hydrogen sulfide.4.2 Information on the correct use of detector tubes andlength-of-stain dosimeters is presented.5. Significanc
20、e and Use5.1 GeneralHydrogen sulfide is nearly ubiquitous. Itoccurs naturally in volcanic gases, in sulfur springs andfumaroles, in decaying of plant and animal protein, and inintestines as a result of bacterial action. Hydrogen sulfide is aserious hazard to the health of workers employed in energyp
21、roduction from hydrocarbon or geothermal sources, in theproduction of fibers and sheets from viscose syrup, in theproduction of deuterium oxide (heavy water), in tanneries,sewers, sewage treatment and animal waste disposal, in workbelow ground, on fishing boats, and in chemical operations,including
22、the gas and oil industry.5.2 In 29 CFR 1910.1000, the Federal Occupational Safetyand Health Administration designates that worker exposure tocertain gases and vapors must not be exceeded in workplaceatmospheres at concentrations above specific values, averagedover a certain time span. Hydrogen sulfi
23、de is included in thislist. Refer also to NIOSH Criteria for a Recommended Stan-dard, Occupational Exposure to Hydrogen Sulfide.5.3 This practice will provide means for the determinationof airborne concentrations of hydrogen sulfide.5.4 This practice provides means for either personal or areasamplin
24、g and for short-term or time-weighted average (TWA)measurements. Refer to Threshold Limit Values for ChemicalSubstances in the Work Environment.6. Detector Tubes, Short-Term (1,4-9)6.1 GeneralShort-term detector tubes are used for grab-sampling. They allow determination of hydrogen sulfide con-centr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD491320002011STANDARDPRACTICEFORDETERMININGCONCENTRATIONOFHYDROGENSULFIDEBYDIRECTREADINGLENGTHOFSTAINVISUALCHEMICALDETECTORS

链接地址:http://www.mydoc123.com/p-518390.html