《ASTM D4822-1988(2003) Standard Guide for Selection of Methods of Particle Size Analysis of Fluvial Sediments (Manual Methods)《河水中沉淀物粒度分析方法的选择》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4822-1988(2003) Standard Guide for Selection of Methods of Particle Size Analysis of Fluvial Sediments (Manual Methods)《河水中沉淀物粒度分析方法的选择》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4822 88 (Reapproved 2003)Standard Guide forSelection of Methods of Particle Size Analysis of FluvialSediments (Manual Methods)1This standard is issued under the fixed designation D 4822; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the selection of methods for deter-mining the size distribution of f
3、luvial sediments particles in therange greater than 0.45 m using manual methods. Manualmethods are defined as those methods that require the operatorto do some actual measurements and calculations. An auto-mated method would be one which, after the sample isprepared and inserted into an instrument,
4、the instrument(machine) does the measuring and calculations, not the opera-tor. Not all manual methods are presented in this guide.However, where available, at least two methods for eachparticle size range are given.1.2 This standard does not purport to address all of thesafety concerns, if any, ass
5、ociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 422 Test Method for Particle-Size Analysis of Soils2D 1
6、129 Terminology Related to Water3D 4410 Terminology of Fluvial Sediment4D 4411 Guide for Sampling Fluvial Sediment in Motion4E20 Practice for Particle Size Analysis of Particulate Sub-stances in the Range of 0.2 to 75 Micrometers by OpticalMicroscopy53. Terminology3.1 Definitions:3.1.1 For definitio
7、ns of terms used in this guide, refer toTerminologies D 1129 and D 4410.3.2 Definitions of Terms Specific to This Standard:3.2.1 For definitions of terms used in this guide, refer toTerminology D 4410.3.2.2 particle counta method of particle size analysis inwhich the number of particles in the vario
8、us size ranges arecounted manually.3.2.3 particle sizethe diameter, usually the intermediatediameter, of a particle measured by settling, sieving, micro-metric, or direct measurement methods (see 5.2).3.2.4 particle size distributionthe relative amount of asediment sample in a range of specific size
9、s in terms ofpercentages by mass, volume, or number, finer than a givenparticle size.4. Summary of Guide4.1 This guide consists of suggested manual test methodsfor analyzing fluvial sediment samples for particle size distri-bution.5. Significance and Use5.1 This guide is general and useful in helpin
10、g the user todetermine an appropriate manual test method for determiningthe particle size distribution of fluvial sediments. The sug-gested test methods are not described in this guide, butreferences are given so that the user may obtain more infor-mation about each test method.5.2 It should be note
11、d that different test methods may andoften times do produce different particle size distributions forthe same sample. This is due in part to the different testmethods requiring native or distilled water, differences indispersion methods used, and differences in what the testmethod is measuring, that
12、 is, physical or sedimentation diam-eter.6. Sampling6.1 Collect the samples in accordance with Guide D 4411 or“Field Methods for Measurement of Fluvial Sediments” (1).61This guide is under the jurisdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.07 on Sedim
13、ents, Geomorphology,and Open Channel Flow.Current edition approved June 10, 2003. Published August 2003. Originallyapproved in 1988. Last previous edition approved in 1999 as D 4822 88 (1999).2Annual Book of ASTM Standards, Vol 04.08.3Annual Book of ASTM Standards, Vol 11.01.4Annual Book of ASTM Sta
14、ndards, Vol 11.02.5Discontinued. See 1995 Annual Book of ASTM Standards, Vol 14.02.6The boldface numbers in parentheses refer to the list of references at the end ofthis guide.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Proced
15、ure7.1 Visually inspect the sample or streambed to estimateparticle size ranges contained in the sample.7.2 Enter Table 1 from the left. Determine the test methodsthat are appropriate for: (1) the estimated particle size con-tained in the sample, and (2) the desired reporting units.7.3 Details on ea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD482219882003STANDARDGUIDEFORSELECTIONOFMETHODSOFPARTICLESIZEANALYSISOFFLUVIALSEDIMENTSMANUALMETHODS

链接地址:http://www.mydoc123.com/p-518127.html