《ASTM D4821-2016 Standard Guide for Carbon Black&x2014 Validation of Test Method Precision and Bias《碳黑的标准指南&x2014 试验方法精度和偏差的验证》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4821-2016 Standard Guide for Carbon Black&x2014 Validation of Test Method Precision and Bias《碳黑的标准指南&x2014 试验方法精度和偏差的验证》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4821 15D4821 16Standard Guide forCarbon BlackValidation of Test Method Precision andBias1This standard is issued under the fixed designation D4821; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers procedures for using theASTM Standard Reference Blacks2 (SRBs) and the HT and INR Iodine NumberStandards to c
3、ontinuously monitor the precision of those carbon black test methods for which reference values have beenestablished. It also offers guidelines for troubleshooting various test methods.1.2 This guide defines the environmental conditions that are required for laboratories that perform carbon black te
4、sting activitiesfor those test methods under D24s jurisdiction.1.3 This guide establishes procedures for the use of x-charts to continuously monitor those tests listed in Section 2 for within-labprecision (repeatability) and between-lab accuracy (reproducibility).1.4 This guide provides a statistica
5、l procedure for improving test reproducibility when a laboratory cannot physically calibrateits apparatus to obtain the reference values of the ASTM reference blacks, within the ranges given in this guide.2. Referenced Documents2.1 ASTM Standards:3D1510 Test Method for Carbon BlackIodine Adsorption
6、NumberD1513 Test Method for Carbon Black, PelletedPour DensityD1765 Classification System for Carbon Blacks Used in Rubber ProductsD2414 Test Method for Carbon BlackOil Absorption Number (OAN)D3265 Test Method for Carbon BlackTint StrengthD3324 Practice for Carbon BlackImproving Test Reproducibility
7、 Using ASTM Standard Reference Blacks (Withdrawn2002)4D3493 Test Method for Carbon BlackOil Absorption Number of Compressed Sample (COAN)D6556 Test Method for Carbon BlackTotal and External Surface Area by Nitrogen AdsorptionE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE
8、2282 Guide for Defining the Test Result of a Test MethodE2586 Practice for Calculating and Using Basic Statistics3. Terminology3.1 Definitions:3.1.1 accepted reference value, na value that serves as an agreed-upon reference for comparison, and which is derived as: (1)a theoretical or established val
9、ue, based on scientific principles, (2) an assigned or certified value, based on experimental work ofsome national or international organization, or (3) a consensus or certified value, based on collaborative experimental work underthe auspices of a scientific or engineering group.3.1.1.1 Discussion1
10、 This guide is under the jurisdiction of ASTM Committee D24 on Carbon Black and is the direct responsibility of Subcommittee D24.61 on Carbon Black Sampling andStatistical Analysis.Current edition approved Jan. 1, 2015July 1, 2016. Published February 2015August 2016. Originally approved in 1988. Las
11、t previous edition approved in 20142015 asD4821 14.D4821 15. DOI: 10.1520/D4821-15.10.1520/D4821-16.2 Standard Reference Blacks are available from Laboratory Standards thus, “standarddeviation of test results among operators in a laboratory,” or “day-to-day standard deviation within a laboratory for
12、 the sameoperator.”3.1.7.2 DiscussionBecause the training of operators, the agreement of different pieces of equipment in the same laboratory and the variation ofenvironmental conditions with longer time intervals all depend on the degree of within-laboratory control, the intermediatemeasures of pre
13、cision are likely to vary appreciably from laboratory to laboratory. Thus, intermediate precisions may be morecharacteristic of individual laboratories than of the test method. E1773.1.8 intermediate precision conditions, nconditions under which test results are obtained with the same test method us
14、ing testunits or test specimens taken at random from a single quantity of material that is as nearly homogeneous as possible, and withchanging conditions such as operator, measuring equipment, location within the laboratory, and time. E1773.1.9 measured value, nan observed test results as opposed to
15、 a standard value. D33243.1.10 normalization, nthe practice of applying a statistical correction to test measurements to improve accuracy.3.1.10.1 DiscussionThe correction of test data using a straight-line equation (linear regression) where measurements of ASTM reference blacks areanalyzed with pub
16、lished accepted reference values to determine a slope and y-intercept. Normalization is a proven technique toimprove the accuracy or reproducibility of laboratory data when all other means of calibration do not satisfactorily achieve adesired state of calibration.3.1.11 observation, nthe process of
17、obtaining information regarding the presence or absence of an attribute of a test specimen,or of making a reading on a characteristic or dimension of a test specimen. E22823.1.12 observed value, nthe value obtained by making an observation. E22823.1.13 precision, nthe closeness of agreement between
18、independent test results obtained under stipulated conditions.3.1.13.1 DiscussionD4821 162Precision depends on random errors and does not relate to the accepted reference value.3.1.13.2 DiscussionThe measure of precision usually is expressed in terms of imprecision and computed as a standard deviati
19、on of the test results. Lessprecision is reflected by a larger standard deviation.3.1.13.3 Discussion“Independent test results” means results obtained in a manner not influenced by any previous result on the same or similar testobject. Quantitative measures of precision depend critically on the stip
20、ulated conditions. Repeatability and reproducibilityconditions are particular sets of extreme stipulated conditions. E1773.1.14 regression of standard values on measured values, nstatistical equation derived by the method of least-squares. D33243.1.15 repeatability, nprecision under repeatability co
21、nditions.3.1.15.1 DiscussionRepeatability is one of the concepts or categories of the precision of a test method.3.1.15.2 DiscussionMeasures of repeatability defined in this compilation are repeatability standard deviation and repeatability limit. E1773.1.16 repeatability conditions, nconditions whe
22、re independent test results are obtained with the same method on identical testitems in the same laboratory by the same operator using the same equipment within short intervals of time.3.1.16.1 DiscussionSee precision, the “same operator, same equipment” requirement means that for a particular step
23、in the measurement process, thesame combination of operator and equipment is used for every test result. Thus, one operator may prepare the test specimens, asecond measure the dimensions and a third measure the mass in a test method for determining density.3.1.16.2 DiscussionBy “in the shortest prac
24、tical period of time” is meant that the test results, at least for one material, are obtained in a time periodnot less than in normal testing and not so long as to permit significant change in test material, equipment or environment. E1773.1.17 repeatability limit (r), nthe value below which the abs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD48212016STANDARDGUIDEFORCARBONBLACKX2014VALIDATIONOFTESTMETHODPRECISIONANDBIAS 碳黑 标准 指南 X2014 试验

链接地址:http://www.mydoc123.com/p-518126.html