《ASTM D4794-1994(2003) Standard Test Method for Determination of Ethoxyl or Hydroxyethoxyl Substitution in Cellulose Ether Products by Gas Chromatography《用气相色谱法测定纤维素醚产品中羟乙基替代物的标准试验方.pdf》由会员分享,可在线阅读,更多相关《ASTM D4794-1994(2003) Standard Test Method for Determination of Ethoxyl or Hydroxyethoxyl Substitution in Cellulose Ether Products by Gas Chromatography《用气相色谱法测定纤维素醚产品中羟乙基替代物的标准试验方.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4794 94 (Reapproved 2003)Standard Test Method forDetermination of Ethoxyl or Hydroxyethoxyl Substitution inCellulose Ether Products by Gas Chromatography1This standard is issued under the fixed designation D 4794; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable to the determination ofethox
3、yl or hydroxyethoxyl substitution in cellulose ether prod-ucts by a Zeisel gas chromatographic technique.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concern
4、s, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 5 and Note 3.2. Summary of Test Method2.1
5、 When a cellulose ether containing ethyl or hydroxyethylsubstitutes is allowed to react with hydriodic acid, one mole ofiodoethane is liberated for each mole of ethoxyl or hydroxy-ethoxyl ether substituted on the cellulose chain. The iodoet-hane is extracted in-situ with o-xylene and quantitated by
6、gaschromatography using an internal standard technique. It isrecommended to run duplicate samples.3. Apparatus3.1 Gas Chromatograph with thermal conductivity detectorand heated injection port.3.2 Electronic Integrator.3.3 Columnstainless steel, 1829 mm in length, 3.2 mm inoutside diameter, packed wi
7、th the reagent in 4.6, coiled to fitthe chromatograph used; or equivalent column and packing asappropriate.3.4 Syringe,10L.3.5 Reaction Vials, Caps, and Heating Block.23.6 Syringe, 100 L.3.7 Cover, stainless steel, fabricated to cover the heatingblock.4. Reagents and Materials4.1 Purity of ReagentsR
8、eagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is
9、 first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.4.2 Iodoethane, 99 % minimum.4.3 O-xylene.4.4 Toluene.4.5 Hydriodic Acid, 57 % (sp gr 1.69 to 1.70).4.6 Column Packing, 10 % methyl silicone stationary phaseUSP code
10、 G1 coated on inert diatomite solid support USPcode S1A, 100/120 mesh.5. Hazards5.1 Safety precautions must be taken for handling of hydri-odic acid.5.2 During the reaction, the glass vials are under pressure.Exercise precaution in handling the hot vials.1This test method is under the jurisdiction o
11、f ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.36 on Cellulose and Cellulose Derivatives.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1988. Last previous edition approved in 19
12、94 as D 4794 94 (1998).2The sole source of supply of a heating block, Silli-Therm Heating Module,Reacti-Block 21, Reacti-Vials, and Minnert valve tops, known to the committee atthis time is the Pierce Chemical Company P.O. Box 117, Rockford, IL 611059976.If you are aware of alternative suppliers, pl
13、ease provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For sugge
14、stions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International,
15、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Apparatus Preparation and Conditioning6.1 Column (Note 1)Columns are packed with reagentunder vacuum and mechanical vibration using silanized glasswool to contain the packing. Install each in the gas chromato-gra
16、ph to facilitate on column injection. Condition the columnat 200C for 12 h, then allow it to come to equilibrium underthe conditions described below:Oven temperature, C 130 isothermalInjection port temperature, C 200Detector temperature, C 250Detector current, ma 175 maAttenuation 1Polarity ACarrier
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD479419942003STANDARDTESTMETHODFORDETERMINATIONOFETHOXYLORHYDROXYETHOXYLSUBSTITUTIONINCELLULOSEETHERPRODUCTSBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-517998.html