ASTM D4735-2009(2014) Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《采用气相色谱法测定精制苯中微量噻吩的标准试验方法》.pdf
《ASTM D4735-2009(2014) Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《采用气相色谱法测定精制苯中微量噻吩的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4735-2009(2014) Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《采用气相色谱法测定精制苯中微量噻吩的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4735 09 (Reapproved 2014)Standard Test Method forDetermination of Trace Thiophene in Refined Benzene byGas Chromatography1This standard is issued under the fixed designation D4735; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of thiophenein refined benzene in the range from 0.8
3、0 to 1.80 mg/kg for theFlame Photometric Detector (FPD), and from 0.14 to 2.61mg/kg for the Pulsed Flame Photometric Detector (PFPD). Forthe PFPD, the minimum level of quantitation (LOQ) is 0.14mg/kg and the minimum level of detection (LOD) is 0.04mg/kg, as described inASTM Research Report RR:D16-10
4、38.2The range of the test method may be extended by modifyingthe sample injection volume, split ratios, calibration range, orsample dilution with thiophene-free solvent.1.2 This test method has been found applicable to benzenecharacteristic of the type described in Specifications D2359and D4734 and
5、may be applicable to other types or grades ofbenzene only after the user has demonstrated that the procedurecan completely resolve thiophene from the other organiccontaminants contained in the sample.1.3 The following applies to all specified limits in this testmethod: for purposes of determining co
6、nformance to appli-cable specification using this test method, an observed value ora calculated value shall be rounded off “to the nearest unit” inthe last right-hand digit used in expressing the specificationlimit in accordance with the rounding-off method of PracticeE29.1.4 The values stated in SI
7、 units are to be regarded asstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory lim
8、itations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD1685 Test Method for Traces of Thiophene in Benzene bySpectrophotometry (Withdrawn 2009)4D2359 Specification for Refined Benzene-535D3437 Practice for
9、Sampling and Handling Liquid CyclicProductsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD4734 Specification for Refined Benzen
10、e-545D6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE260 Practic
11、e for Packed Column Gas ChromatographyE355 Practice for Gas Chromatography Terms and Relation-shipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE840 Practice for Using Flame Photometric Detectors in GasChromatographyE1510 Practice for Installing Fus
12、ed Silica Open TubularCapillary Columns in Gas Chromatographs1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.04 on Instrumental Analysis.Current edition approved Feb. 1, 2014. Publishe
13、d February 2014. Originallyapproved in 1987. Last previous edition approved in 2009 as D4735 09. DOI:10.1520/D4735-09R14.2Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:D16-1038. ContactASTM CustomerService at serviceastm.org.3F
14、or referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is refer
15、enced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120053. Summary of Test Met
16、hod3.1 The thiophene concentration in refined benzene is de-termined at the milligram thiophene per kilogram sample levelusing conventional gas-liquid chromatography with a flamephotometric detector (FPD) or pulsed flame photometric de-tector (PFPD). A reproducible volume of sample is injected.Quant
17、itative results are obtained by the external standardtechnique using the measured peak area of thiophene.4. Significance and Use4.1 This test method is suitable for setting specifications onbenzene and for use as an internal quality control tool wherebenzene is either produced or used in a manufactu
18、ring process.4.2 This test method was found applicable for determiningthiophene in refined benzene conforming to the specificationsdescribed in Specification D2359 and may be applicabletoward other grades of benzene if the user has taken thenecessary precautions as described in the text.4.3 This tes
19、t method was developed as an alternative tech-nique to Test Method D1685.5. Apparatus5.1 Gas ChromatographAny chromatograph having aflame photometric detector (FPD or PFPD) may be used whichcan operate at the typical conditions described in Table 1. Theuser is referred to Practices E260 and E355 for
20、 additionalinformation about gas chromatography principles and proce-dures. An automatic sampler is recommended. The GC shouldhave the following performance characteristics:5.1.1 Column Temperature ProgrammerThe chromato-graph shall be capable of linear programmed temperatureoperation over a range s
21、ufficient for the separation of thecompounds of interest. The programming shall be sufficientlyreproducible to obtain retention time repeatability throughoutthe scope of the analysis.5.1.2 Sample Inlet SystemThe sample inlet system shallhave variable temperature control capable of operating con-tinu
22、ously at a temperature up to the maximum column tem-perature employed. The sample inlet system shall allow aconstant volume of sample to be injected by means of asyringe. For the PFPD a heated flash vaporizing injectordesigned to provide a linear sample split injection (that is,50:1) is required for
23、 proper sample introduction. The associ-ated carrier gas flow controls shall be of sufficient precision toprovide reproducible column flows and split ratios in order tomaintain analytical integrity.5.2 ColumnThe column shall provide complete resolutionof thiophene from benzene and any other hydrocar
24、bon impu-rities because of potential quenching effects by hydrocarbonson the light emissions from the thiophene. The columnsdescribed in Table 1 have been judged satisfactory. The user isreferred to Practice E1510 for assistance on installing fusedsilica capillary columns into the gas chromatograph.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD473520092014STANDARDTESTMETHODFORDETERMINATIONOFTRACETHIOPHENEINREFINEDBENZENEBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-517842.html