ASTM D4735-2009 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《用气相色谱法测定精制苯中微量噻吩的试验方法》.pdf
《ASTM D4735-2009 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《用气相色谱法测定精制苯中微量噻吩的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4735-2009 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography《用气相色谱法测定精制苯中微量噻吩的试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4735 09Standard Test Method forDetermination of Trace Thiophene in Refined Benzene byGas Chromatography1This standard is issued under the fixed designation D4735; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of thiophenein refined benzene in the range from 0.80 to 1.80 mg/kg f
3、or theFlame Photometric Detector (FPD), and from 0.14 to 2.61mg/kg for the Pulsed Flame Photometric Detector (PFPD). Forthe PFPD, the minimum level of quantitation (LOQ) is 0.14mg/kg and the minimum level of detection (LOD) is 0.04mg/kg, as described in ASTM Research Report RR: D16-1038.2The range o
4、f the test method may be extended bymodifying the sample injection volume, split ratios, calibrationrange, or sample dilution with thiophene-free solvent.1.2 This test method has been found applicable to benzenecharacteristic of the type described in Specifications D2359and D4734 and may be applicab
5、le to other types or grades ofbenzene only after the user has demonstrated that the procedurecan completely resolve thiophene from the other organiccontaminants contained in the sample.1.3 The following applies to all specified limits in this testmethod: for purposes of determining conformance to ap
6、pli-cable specification using this test method, an observed value ora calculated value shall be rounded off “to the nearest unit” inthe last right-hand digit used in expressing the specificationlimit in accordance with the rounding-off method of PracticeE29.1.4 The values stated in SI units are to b
7、e regarded asstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
8、to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD1685 Test Method for Traces of Thiophene in Benzene bySpectrophotometryD2359 Specification for Refined Benzene-535D3437 Practice for Sampling and Handling Liquid Cycl
9、icProductsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD4734 Specification for Refined Benzene-545D6809 Guide for Quality Cont
10、rol and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE260 Practice for Packed Column Gas Chromatog
11、raphyE355 Practice for Gas Chromatography Terms and Rela-tionshipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE840 Practice for Using Flame Photometric Detectors inGas ChromatographyE1510 Practice for Installing Fused Silica Open TubularCapillary C
12、olumns in Gas Chromatographs1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.04 on Instrumental Analysis.Current edition approved Dec. 1, 2009. Published December 2009. Originallyapprov
13、ed in 1987. Last previous edition approved in 2002 as D4735 02. DOI:10.1520/D4735-09.2Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR: D16-1038.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM
14、Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
15、cken, PA 19428-2959, United States.2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120043. Summary of Test Method3.1 The thiophene concentration in refined benzene is de-termined at the milligram thiophene per kilogram sample levelusing conventional gas-liquid chromatography
16、 with a flamephotometric detector (FPD) or pulsed flame photometric de-tector (PFPD). A reproducible volume of sample is injected.Quantitative results are obtained by the external standardtechnique using the measured peak area of thiophene.4. Significance and Use4.1 This test method is suitable for
17、setting specifications onbenzene and for use as an internal quality control tool wherebenzene is either produced or used in a manufacturing process.4.2 This test method was found applicable for determiningthiophene in refined benzene conforming to the specificationsdescribed in Specification D2359 a
18、nd may be applicabletoward other grades of benzene if the user has taken thenecessary precautions as described in the text.4.3 This test method was developed as an alternative tech-nique to Test Method D1685.5. Apparatus5.1 Gas ChromatographAny chromatograph having aflame photometric detector (FPD o
19、r PFPD) may be used whichcan operate at the typical conditions described in Table 1. Theuser is referred to Practices E260 and E355 for additionalinformation about gas chromatography principles and proce-dures. An automatic sampler is recommended. The GC shouldhave the following performance characte
20、ristics:5.1.1 Column Temperature ProgrammerThe chromato-graph shall be capable of linear programmed temperatureoperation over a range sufficient for the separation of thecompounds of interest. The programming shall be sufficientlyreproducible to obtain retention time repeatability throughoutthe scop
21、e of the analysis.5.1.2 Sample Inlet SystemThe sample inlet system shallhave variable temperature control capable of operating con-tinuously at a temperature up to the maximum column tem-perature employed. The sample inlet system shall allow aconstant volume of sample to be injected by means of asyr
22、inge. For the PFPD a heated flash vaporizing injectordesigned to provide a linear sample split injection (that is,50:1) is required for proper sample introduction. The associ-ated carrier gas flow controls shall be of sufficient precision toprovide reproducible column flows and split ratios in order
23、 tomaintain analytical integrity.5.2 ColumnThe column shall provide complete resolutionof thiophene from benzene and any other hydrocarbon impu-rities because of potential quenching effects by hydrocarbonson the light emissions from the thiophene. The columnsdescribed in Table 1 have been judged sat
24、isfactory. The user isreferred to Practice E1510 for assistance on installing fusedsilica capillary columns into the gas chromatograph.5.3 DetectorAny flame photometric detector (FPD orPFPD) can be used, provided it has sufficient sensitivity toproduce a minimum peak height twice that of the base no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47352009STANDARDTESTMETHODFORDETERMINATIONOFTRACETHIOPHENEINREFINEDBENZENEBYGASCHROMATOGRAPHY 用气相

链接地址:http://www.mydoc123.com/p-517841.html