ASTM D4684-2017 Standard Test Method for Determination of Yield Stress and Apparent Viscosity of Engine Oils at Low Temperature《测定发动机油在低温下屈服应力和表观粘度的标准试验方法》.pdf
《ASTM D4684-2017 Standard Test Method for Determination of Yield Stress and Apparent Viscosity of Engine Oils at Low Temperature《测定发动机油在低温下屈服应力和表观粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4684-2017 Standard Test Method for Determination of Yield Stress and Apparent Viscosity of Engine Oils at Low Temperature《测定发动机油在低温下屈服应力和表观粘度的标准试验方法》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4684 14D4684 17Standard Test Method forDetermination of Yield Stress and Apparent Viscosity ofEngine Oils at Low Temperature1This standard is issued under the fixed designation D4684; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This
3、 test method covers the measurement of the yield stress and viscosity of engine oils after cooling at controlled rates overa period exceeding 45 h to a final test temperature between 10 C and 40 C. The precision is stated for test temperatures from40 C to 15 C. The viscosity measurements are made at
4、 a shear stress of 525 Pa over a shear rate of 0.4 s1to 15 s1. Theviscosity as measured at this shear stress was found to produce the best correlation between the temperature at which the viscosityreached a critical value and borderline pumping failure temperature in engines.1.2 This test method con
5、tain two procedures: Procedure A incorporates several equipment and procedural modifications fromTest Method D468402 that have shown to improve the precision of the test, while Procedure B is unchanged from Test MethodD468402. Additionally, Procedure A applies to those instruments that utilize therm
6、oelectric cooling technology or directrefrigeration technology of recent manufacture for instrument temperature control. Procedure B can use the same instruments usedin Procedure A or those cooled by circulating methanol.1.3 Procedure A of this test method has precision stated for a yield range from
7、 less than 35 Pa to 210 Pa and apparent viscosityrange from 4300 mPas to 270 000 mPas. The test procedure can determine higher yield stress and viscosity levels.1.4 This test method is applicable for unused oils, sometimes referred to as fresh oils, designed for both light duty and heavyduty engine
8、applications. It also has been shown to be suitable for used diesel and gasoline engine oils. The applicability topetroleum products other than engine oils has not been determined.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this sta
9、ndard.1.5.1 ExceptionThis test method uses the SI based unit of milliPascal second (mPas) for viscosity which is equivalent to,centiPoise (cP).1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standa
10、rd to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Dev
11、elopment of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D3829 Test Method for Predicting the Borderline Pumping Temperature of Engine OilE563 Practice for Preparation
12、and Use of an Ice-Point Bath as a Reference TemperatureE644 Test Methods for Testing Industrial Resistance ThermometersE1137 Specification for Industrial Platinum Resistance ThermometersE2877 Guide for Digital Contact Thermometers1 This test method is under the jurisdiction ofASTM Committee D02 on P
13、etroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved July 1, 2014May 1, 2017. Published August 2014May 2017. Originally approved in 1987. Last previous edition approved in 20122014 asD4684 12.D4684 14. DOI:
14、 10.1520/D4684-14.10.1520/D4684-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an AS
15、TM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In a
16、ll cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 ISO S
17、tandard:3ISO 17025 General Requirements for the Competence of Testing and Calibration LaboratoriesISO Guide 34 General Requirements for the Competence of Reference Material Producers3. Terminology3.1 Definitions:3.1.1 apparent viscosity, nthe determined viscosity obtained by use of this test method.
18、3.1.2 Digital Contact Thermometerdigital contact thermometer (DCT), nan electronic device consisting of a digital displayand associated temperature sensing probe.3.1.2.1 DiscussionThis device consists of a temperature sensor connected to a measuring instrument; this instrument measures the temperatu
19、re-dependent quantity of the sensor, computes the temperature from the measured quantity, and provides a digital output or display,or both, of the temperature. The temperature sensing probe is in contact with the material whose temperature is being measured.This device is output. This digital output
20、 goes to a digital display and/or recording device that may be internal or external to thedevice. These devices are sometimes referred to as a“digital digital thermometer.thermometers.”NOTE 1Portable electronic thermometers (PET) is an acronym sometimes used to refer to a subset of the devices cover
21、ed by this definition.3.1.2.2 DiscussionPET is an acronym for portable electronic thermometers, a subset of digital contact thermometers (DCT).3.1.3 Newtonian oil or fluid, nan oil or fluid that at a given temperature exhibits a constant viscosity at all shear rates or shearstresses.3.1.4 non-Newton
22、ian oil or fluid, nan oil or fluid that at a given temperature exhibits a viscosity that varies with changingshear stress or shear rate.3.1.5 shear rate, nthe velocity gradient in fluid flow. For a Newtonian fluid in a concentric cylinder rotary viscometer in whichthe shear stress is measured at the
23、 inner cylinder surface (such as this apparatus, described in 6.1), and ignoring any end effects,the shear rate is given as follows: 5 2!Rs2Rs22Rr2 (1)5 4pi!Rs2t Rs22Rr2! (2)where: = shear rate at the surface of the rotor in reciprocal seconds, s1, = angular velocity, rad/s,Rs = stator radius, mm,Rr
24、 = rotor radius, mm, andt = time in seconds for one revolution of the rotor.For the specific apparatus being described in 6.1.1, 563/t (3)3.1.6 shear stress, nthe motivating force per unit area for fluid flow. For the rotary viscometer being described, the rotorsurface is the area under shear or the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46842017STANDARDTESTMETHODFORDETERMINATIONOFYIELDSTRESSANDAPPARENTVISCOSITYOFENGINEOILSATLOWTEMPERATURE

链接地址:http://www.mydoc123.com/p-517709.html