《ASTM D4663-2010 Standard Test Method for Polyurethane Raw Materials Determination of Hydrolyzable Chlorine of Isocyanates《聚亚胺酯原材料法测定异氰酸酯中可水解氯含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4663-2010 Standard Test Method for Polyurethane Raw Materials Determination of Hydrolyzable Chlorine of Isocyanates《聚亚胺酯原材料法测定异氰酸酯中可水解氯含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4663 10Standard Test Method forPolyurethane Raw Materials: Determination of HydrolyzableChlorine of Isocyanates1This standard is issued under the fixed designation D4663; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method determines the hydrolyzable chlorinecontent of toluene-2,4-diisocyanate, toluene-2,6-d
3、iisocyanate,or mixtures of the two. It is acceptable to apply this test methodto other isocyanates of suitable solubility. (See Note 1.) Themain sources of hydrolyzable chlorine in the isocyanates arecarbamoyl chloride and dissolved phosgene. Both of thesecompounds react with alcohols and water, for
4、ming ureas,carbamates, carbon dioxide, and hydrochloric acid. (See Note2.)1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
5、 the applica-bility of regulatory limitations prior to use.NOTE 1It is possible that this test method is applicable crudepolymeric isocyanates. However, the precision with crude polymericisocyanates has not been established.NOTE 2There is no known ISO equivalent to this standard.2. Referenced Docume
6、nt2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1193 Specification for Reagent Water3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod see Terminology D883.3.2 Description of Term Specific to This Standard.3.2.1 hydrolyzable chloridethe low level chlorine-conta
7、ining components of the isocyanate, such as carbamoylchlorides, which react with water or alcohol to form HCl.4. Summary of Test Method4.1 The hydrolyzable chlorine reacts with methanol, liber-ating hydrochloric acid. The titratable chlorides are thendetermined potentiometrically using a standard si
8、lver nitratesolution.5. Significance and Use5.1 This test method can be used for research or for qualitycontrol to characterize toluene diisocyanates. Hydrolyzablechlorine correlates with performance in some polyurethanesystems.6. Interferences6.1 Thiocyanate, cyanide, sulfide, bromide, iodide, or o
9、thersubstances capable of reacting with silver ion, as well assubstances capable of reducing silver ion in acid solution, willinterfere with the determination.7. Apparatus7.1 Weighing Bottle, or any device capable of weighing aliquid by difference to the nearest 0.1 g.7.2 Hot Plate, with magnetic st
10、irrer.7.3 Potentiometric Titrator, or pH meter.7.4 Combination Silver Billet Electrode.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomers.Current edition approved July 1,
11、2010. Published August 2010. Originallyapproved in 1987. Last previous edition approved in 2004 as D4663 - 98(2004).DOI: 10.1520/D4663-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
12、information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8. Reagents and Materials8.1 Purity of Rea
13、gentsUse reagent grade chemicals in alltests. Unless otherwise indicated, it is intended that all reagentsconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society where suchspecifications are available.3Other grades may be used, pro-vided it is first asce
14、rtained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.8.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type I of Specification D1193.8.3 Concentrated Nitric A
15、cid (HNO3sp gr 1.42).8.4 Methanol.8.5 Silver Nitrate Standard Solution (0.01 N)Standardizewith standard hydrochloric acid, either gravimetrically orpotentiometrically, frequently enough to detect changes of0.0005 N.9. Sampling9.1 Since organic isocyanates react with atmospheric mois-ture, take speci
16、al precautions in sampling. Usual samplingmethods, even when carried out rapidly, can cause contamina-tion of the sample with insoluble urea. Therefore, blanket thesample with dry air or nitrogen at all times. (WarningManydiisocyanates are known or suspected sensitizers. Over-exposure to diisocyanat
17、es can lead to adverse health effects,which include the development of occupational asthma andother respiratory, skin, and eye effects. Engineering controlsand/or personal protective equipment, including respiratory,skin, and eye protection, are to be used when there is apotential for over-exposure
18、to diisocyanates. The productsuppliers Material Data Safety Sheet (MSDS) provides moredetailed information about potential adverse health effects andother important safety and handling information. Alwaysfollow the specific instructions provided on the MSDS.)10. Test Conditions10.1 Since isocyanates
19、 react with moisture, keep laboratoryhumidity low, preferably around 50 % relative humidity.11. Procedure11.1 Weigh (by difference to the nearest 0.1 g) 9 to 11 g ofsample from a sampling weighing bottle into a clean, dry400-mL beaker (Note 3). Add 50 mL of methanol and stir. Stircontinually while t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46632010STANDARDTESTMETHODFORPOLYURETHANERAWMATERIALSDETERMINATIONOFHYDROLYZABLECHLORINEOFISOCYANATES

链接地址:http://www.mydoc123.com/p-517645.html