ASTM D4642-2004(2016) Standard Test Method for Platinum in Reforming Catalysts by Wet Chemistry《采用湿化学法测定重整催化剂中铂的标准试验方法》.pdf
《ASTM D4642-2004(2016) Standard Test Method for Platinum in Reforming Catalysts by Wet Chemistry《采用湿化学法测定重整催化剂中铂的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4642-2004(2016) Standard Test Method for Platinum in Reforming Catalysts by Wet Chemistry《采用湿化学法测定重整催化剂中铂的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4642 04 (Reapproved 2016)Standard Test Method forPlatinum in Reforming Catalysts by Wet Chemistry1This standard is issued under the fixed designation D4642; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of platinum innonzeolitic, fresh reforming catalysts containing platinum ast
3、he only precious metal, in the range of concentration of 0.200to 0.700 weight %.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with
4、 its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE177 Practice for Use of the Te
5、rms Precision and Bias inASTM Test MethodsE288 Specification for Laboratory Glass Volumetric FlasksE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 U.S. Federal Specification:NNN-P-395C Tolerance fo
6、r Class A Pipets33. Summary of Test Method3.1 The ground alumina based reforming catalyst is dis-solved using dilute hydrochloric acid. Stannous chloride isadded to convert the platinum in solution to a yellowish-orange-colored platinum stannous hydrochloride complex. Theabsorbance of the resulting
7、solution is measured comparativelyat 403 nm by spectrophotometry and the platinum content iscalculated from a previously determined value for the absorp-tivity.4. Significance and Use4.1 This test method provides a means of determining theplatinum content of fresh reforming catalysts where the plati
8、-num is supported on an all alumina substrate.44.2 This test method is not intended to cover samplescontaining metals other than platinum. Palladium, rhenium,and rhodium in particular interfere with the spectrophotometricdetermination of platinum.5. Apparatus5.1 Balance, analytical, capable of weigh
9、ing to the nearest0.1 mg.5.2 Beakers, 250-mL, tall form and 600-mL.5.3 Cells, spectrophotometer, 1.0 cm, matched.5.4 Crucibles, platinum, or porcelain, 50-mL.5.5 Desiccator, vacuum.5.6 Filter Paper, fine, ashless, slow filtering, 12.5 cm orequivalent.5.7 Flasks, volumetric, conforming to tolerances
10、specifiedby Specification E288, 500-mL and 1000-mL.5.8 Funnel, filtering, fluted bowl, 65 mm top diameter, 150mm stem.5.9 Graduated Cylinders, 10-mL, 25-mL, 50-mL, 250-mL.5.10 Pipets, conforming to tolerances specified by FederalSpecification NNN-P-395C, 5-mL, 10-mL, 15-mL.5.11 Muffle Furnace, capab
11、le of 1000 6 25C.5.12 Spectrophotometer, capable of measuring absorbancevalues between 200 to 800 nm with a photometric repeatabilityof 60.002 absolute at 1.0 absolute.5.13 Watch Glass, flat, 100 mm.5.14 Watch Glass, ribbed, 65 mm.1This test method is under the jurisdiction of ASTM Committee D32 onC
12、atalysts and is the direct responsibility of Subcommittee D32.03 on ChemicalComposition.Current edition approved Jan. 1, 2016. Published January 2016. Originallyapproved in 1986. Last previous edition approved in 2010 as D464204(2010).DOI: 10.1520/D4642-04R16.2For referenced ASTM standards, visit th
13、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Ph
14、iladelphia, PA 19111-5098.4This test method can be extended to spent reforming catalyst by isolating theplatinum by the methods described in “Assay Procedure for Platinum in ReformingCatalysts,” Analytical Chemistry , Vol 32, No. 6, May 1960, p. 646.Copyright ASTM International, 100 Barr Harbor Driv
15、e, PO Box C700, West Conshohocken, PA 19428-2959. United States15.15 Wash Bottle, polyethylene, 500-mL.5.16 Weighing Vial, 25 by 40 mm.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the
16、specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available. Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determinat
17、ion.56.2 Purity of WaterUnless otherwise indicated, all refer-ences to water used as a reagent mean deionized or distilledwater conforming to Specification D1193.6.3 Aluminum Chloride SolutionDissolve 453.6 g ofAlCl36H2O in water and dilute to a litre with water.6.4 Aqua RegiaMix three parts concent
18、rated hydrochloricacid with one part concentrated nitric acid.6.5 Formic Acid (HCOOH).6.6 Hydrochloric Acid (HCl), concentrated, specific gravity1.19.6.7 Hydrochloric Acid (HCl) Solution, 18 to 19 volume %or 6 N. Dilute 500 mL of concentrated hydrochloric acid to alitre with water.6.8 Hydrochloric A
19、cid (HCl), 3.7 volume % or 1.2 N. Dilute100 mL of concentrated hydrochloric acid to a litre with water.6.9 Hydrogen Peroxide (H2O2), or chlorine gas.6.10 Nitric Acid (HNO3), concentrated specific gravity 1.42.6.11 Platinum Wire, 99.99 % platinum purity.6.12 Standard Platinum Solutions, approximately
20、 1 mgplatinum per mL. Weigh approximately 1 g 6 0.1 mg ofplatinum wire into a 250-mL tall form beaker. Add 7 mL ofconcentrated nitric acid, 21 mL of concentrated hydrochloricacid, cover the beaker using a ribbed watch glass and heat thecontents at 85C. Add additional acid until all of the platinumis
21、 dissolved. Evaporate the resulting chloroplatinic acid solu-tion to a moist salt. Dissolve this material in 20 mL of 6 Nhydrochloric acid solution and evaporate to dryness at 85C.Wash the watch glass and sides of the beaker with about 20 mLof 6 N hydrochloric acid solution and evaporate to drynessa
22、gain. Cool, wash the watch glass and sides of the beaker withabout 20 mL of 6 N hydrochloric acid and dissolve the residuein the beaker. Add a few drops of formic acid to the sample toreduce any remaining nitric acid. Transfer this solution quan-titatively to a 1000-mL volumetric flask.Add an additi
23、onal 300mL of concentrated hydrochloric acid, dilute to volume withwater and mix thoroughly. Allow the solution to cool to roomtemperature and readjust carefully to volume with water andmix. This stock solution contains approximately 1000 ppm ofplatinum and provides suitable aliquots for platinum st
24、andards.Transfer aliquots of 5 mL, 10 mL, and 15 mL, respectively, to3 clean 500-mL volumetric flasks.Add 175 mL of concentratedhydrochloric acid, and 30 mL of stannous chloride solution tothe 500-mL flask. Add sufficient aluminum chloride solution,(approximately 15 mL), to bring the standard to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD464220042016STANDARDTESTMETHODFORPLATINUMINREFORMINGCATALYSTSBYWETCHEMISTRY 采用 化学 测定 重整 催化剂 标准 试验

链接地址:http://www.mydoc123.com/p-517588.html