ASTM D4591-2007(2012) Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry《用差式扫描量热法测定含氟聚合物温度和转化热的标准试验方法.pdf
《ASTM D4591-2007(2012) Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry《用差式扫描量热法测定含氟聚合物温度和转化热的标准试验方法.pdf》由会员分享,可在线阅读,更多相关《ASTM D4591-2007(2012) Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry《用差式扫描量热法测定含氟聚合物温度和转化热的标准试验方法.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4591 07 (Reapproved 2012)Standard Test Method forDetermining Temperatures and Heats of Transitions ofFluoropolymers by Differential Scanning Calorimetry1This standard is issued under the fixed designation D4591; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of De
3、fense.1. Scope1.1 This test method defines conditions for the use ofdifferential scanning calorimetry (DSC) with fluoropolymers.It covers the use of DSC analyses with the fluoropolymers,PTFE, PVDF, PCTFE, and PVF and their copolymers PFA,MFA, FEP, ECTFE, EFEP, VDF/HFP, VDF/TFE/HFP, VDF/CTFE. The tes
4、t method is applicable to the analysis of powdersas well as samples taken from semi-finished or finishedproducts. The nature of fluoropolymers is such that specialprocedures are needed for running DSC analysis and interpret-ing the results.1.2 The values stated in SI units as detailed in IEEE/ASTMSI
5、-10 are to be regarded as the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory l
6、imitations prior to use.NOTE 1There is currently no ISO standard that duplicates this testmethod. ISO 12086-1 and ISO 12086-2 cover similar testing and refer-ence this test method for testing conditions.2. Referenced Documents2.1 ASTM Standards:2D1600 Terminology for Abbreviated Terms Relating toPla
7、sticsD3418 Test Method for Transition Temperatures and En-thalpies of Fusion and Crystallization of Polymers byDifferential Scanning CalorimetryD4894 Specification for Polytetrafluoroethylene (PTFE)Granular Molding and Ram Extrusion MaterialsD4895 Specification for Polytetrafluoroethylene (PTFE)Resi
8、n Produced From DispersionE473 Terminology Relating to Thermal Analysis and Rhe-ologyE793 Test Method for Enthalpies of Fusion and Crystalli-zation by Differential Scanning CalorimetryIEEE/ASTM SI-10 Standard for Use of the InternationalSystem of Units (SI) (the Modern Metric System)2.2 ISO Standard
9、s:3ISO 12086-1 PlasticsFluoropolymer Dispersion andMolding and Extrusion MaterialsPart 1: Designationand SpecificationISO 12086-2 PlasticsFluoropolymer Dispersion andMolding and Extrusion MaterialsPart 2: Preparation ofTest Specimen and Determination of Properties3. Terminology3.1 Definitions:3.1.1
10、differential scanning calorimetry (DSC)a techniquein which the difference in energy inputs into a substance and areference material is measured as a function of temperature,while the substance and reference material are subjected to acontrolled increase or decrease in temperature.3.1.2 Refer to Term
11、inology E473 for general terminologyused in this test method.3.2 Abbreviated Terms:3.2.1 Abbreviations used in this test method are in accor-dance with Terminology D1600.3.2.2 PTFEpolytetrafluoroethylene.3.2.3 PFAperfluoro(alkoxy alkane) resin.3.2.4 FEPperfluoro(ethylene-propene) copolymer.3.2.5 ETF
12、Eethylene-tetrafluoroethylene copolymer.3.2.6 PVDFpoly(vinylidene fluoride).3.2.7 PCTFEpolymonochlorotrifluoroethylene.3.2.8 ECTFEethylene-monochlorotrifluoroethylene co-polymer.3.2.9 EFEPethylene-perfluoroethylene-propene copoly-mer.3.2.10 VDF/HFPvinylidene fluoride-hexafluoropropenecopolymer.1This
13、 test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materi-als.Current edition approved April 1, 2012. Published June 2012. Originallyapproved in 1987. Last previous edition approved in 2007 as D4591 - 07. DO
14、I:10.1520/D4591-07R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Stand
15、ards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.11 VDF/TFEvinylidene fluoride-tetrafluoroethylenecopolymer.3.2.12 VDF/TFE/HFPvinylidene fluor
16、ide-tetrafluoroethylene-hexafluoropropene copolymer.3.2.13 VDF/CTFEvinylidene fluoride-chlorotrifluoroethylene copolymer.3.2.14 PVFpoly(vinyl fluoride).3.2.15 MFAperfluoromethylvinylether-tetrafluoroethyl-ene copolymer.3.2.16 SSGstandard specific gravity.4. Significance and Use4.1 DSC analysis may b
17、e used with fluoropolymers toachieve at least four different objectives as follows:4.1.1 To measure transition temperatures to aid in theidentification of the various fluoropolymers, individually or inmixtures;4.1.2 To compare the relative levels of crystalline content oftwo or more specimens of a s
18、ample of a fluoropolymer relativeto another sample by measuring the heat of fusion;NOTE 2Absolute values of crystalline content cannot be determineduntil values for heats of fusion of the completely crystalline polymers areavailable.4.1.3 To characterize PTFE (DSC thermal curves deter-mined on powde
19、rs or products of PTFE that have never beenmelted convey appreciable information about details of mor-phology and molecular structure);44.1.4 To supplement the test for standard specific gravity(SSG) described in Specifications D4894 and D4895 by usingthe heat of crystallization of pure PTFE homopol
20、ymer, depend-ing on the relative molecular weight of the specimen. Thescopes of these specifications, however, include PTFE resinsmodified with small amounts of comonomers, and manycommercial PTFE resins are modified in this manner. Thesemodifications can have profound effects on crystallizationbeha
21、vior. Published relationships4between heat of crystalliza-tion and molecular weight refer to pure PTFE homopolymersand, therefore, cannot be applied to the modified resins.5. Apparatus5.1 Differential Scanning Calorimeter, capable of heatingand cooling rates of at least 10.0 C/min and of recordingau
22、tomatically the differential heat flow between a specimenand a reference material as a function of time, both to therequired sensitivity and precision. For comparison purposes,the same heating rate shall be used for all calibrations and testruns. Thermal curves are recorded using a computerized data
23、collection system or on a time-based recorder. The resultingcurves are used for the measurement of peak areas either bycomputer integration or an alternative area measuring proce-dure. The instrument should have a sensitivity for heat flowsufficient to provide a precision of 61 % when run using asui
24、table standard for calibration, such as indium. The instru-ment must have a precision of 61 % for either the computer-ized data collections or over a time-base range of 0.1 to 2.0min/cm of chart.NOTE 3Most DSC systems report data with a temperature ordinate.The temperature values are directly relate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD459120072012STANDARDTESTMETHODFORDETERMININGTEMPERATURESANDHEATSOFTRANSITIONSOFFLUOROPOLYMERSBYDIFFERENTIALSCANNINGCALORIMETRY

链接地址:http://www.mydoc123.com/p-517448.html