《ASTM D4532-2015 Standard Test Method for Respirable Dust in Workplace Atmospheres Using Cyclone Samplers《采用气旋采样器对工作场所环境中可吸入粉尘的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4532-2015 Standard Test Method for Respirable Dust in Workplace Atmospheres Using Cyclone Samplers《采用气旋采样器对工作场所环境中可吸入粉尘的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4532 15Standard Test Method forRespirable Dust in Workplace Atmospheres Using CycloneSamplers1This standard is issued under the fixed designation D4532; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides details for the determinationof respirable dust concentration defined in terms of interna-tional
3、 convention in a range from 0.5 to 10 mg/m3inworkplace atmospheres. Specifics are given for sampling andanalysis using any one of a number of commercially availablecyclone samplers.1.2 The limitations on the test method are a minimumweight of 0.1 mg of dust on the filter, and a maximum loadingof 0.3
4、 mg/m2on the filter. The test method may be used athigher loadings if the flow rate can be maintained constant.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This test method contains notes that are explanatory andare n
5、ot part of the mandatory requirements of the method.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to consult andestablish appropriate safety and health practices and deter-mine the applic
6、ability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD3195 Practice for Rotameter CalibrationD5337 Practice for Flow Rate Adjustment of Personal Sam-pling PumpsD6062 Guide for Personal Samplers of H
7、ealth-RelatedAero-sol FractionsD6552 Practice for Controlling and Characterizing Errors inWeighing Collected AerosolsD7440 Practice for Characterizing Uncertainty in Air Qual-ity MeasurementsE1 Specification for ASTM Liquid-in-Glass ThermometersE2251 Specification for Liquid-in-Glass ASTM Thermom-et
8、ers with Low-Hazard Precision Liquids2.2 Other International Standards:3ISO GUM Guide to the Expression of Uncertainty inMeasurement, ISO Guide 98ISO 7708 Air QualityParticle Size Fraction Definitionsfor Health-Related SamplingISO 13137 Workplace Atmospheres Pumps for PersonalSampling of Chemical an
9、d Biological Agents Require-ments and Test MethodsISO 15767 Workplace AtmospheresControlling and Char-acterizing Errors in Weighing Collected AerosolEN 481 Workplace AtmospheresSize Fraction Definitionsfor the Measurement of Airborne Particles in the Work-placeEN 13205 Workplace AtmospheresAssessmen
10、t of Perfor-mance of Instruments for Measurement of Airborne Par-ticle Concentrations3. Terminology3.1 Definitions of Terms Specific to This Standard(otherwise, consult Terminology D1356):3.1.1 respirable conventiontarget specification for sam-pling instruments when the respirable fraction is the fr
11、action ofinterest.3.1.2 respirable fractionmass fraction of total airborneparticles which penetrate to the unciliated airways.3.1.3 respirable sampleraerosol sampler that is used tocollect the respirable fraction of airborne particles from thesurrounding air.1This test method is under the jurisdicti
12、on of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.04 on Workplace AirQuality.Current edition approved Oct. 1, 2015. Published October 2015. Originallyapproved in 1985. Last previous edition approved in 2010 as D4532 10. DOI:10.1520/D4532-15.2For referenced A
13、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4
14、th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.3.1 DiscussionFig. 1 shows the collection efficiencyof an idealized sampler following the internationally-harmonized sampling convent
15、ions of ISO 7708, EN 481,Guide D6062, and Ref. (1).4NOTE 1The definition of the respirable fraction is a compromisebetween previous definitions, available samplers, and the fraction of dustthat penetrates to (rather than deposits in) the alveolar region of the lung.Local legal definitions may differ
16、 from the definition adopted in this testmethod.3.2 For the terms and definitions related to characterizinguncertainty, see ISO GUM and Practice D7440.4. Summary of Test Method4.1 Air is drawn through a cyclone or equivalent samplerfollowed by a tared filter, which is then re-weighed to deter-mine t
17、he mass of respirable dust. The air flow rate and time ofsampling provide the volume from which the dust mass wassampled. A time-weighted average respirable dust concentra-tion is calculated by dividing the mass by the total air volume.NOTE 2Samplers alternative to a cyclone (for example, foam-based
18、 orpersonal cascade impactors) may be used if they have desirable properties(for example, ease of use or uncertainty control) for intended application.Nevertheless, this test method is limited to cyclone samplers.5. Significance and Use5.1 This test method covers the determination of respirabledust
19、concentration in workplace atmospheres.5.2 Variations of the test method are in world-wide use fordetermining compliance relative to occupational exposurelevels.5.3 The test method may be used to verify dust controlmeasures.5.4 The test method may also be applied in research intohealth effects of du
20、st in an occupational setting.6. Apparatus6.1 Sampling UnitThe sampling unit consists of a pump,a sampling head, and tubing connecting the pump and outlet ofthe sampling head. The sampling head consists of a cycloneand a filter assembly.6.1.1 Respirable Dust CycloneVarious types of respirabledust cy
21、clones are commercially available. In general, thesesamplers can be categorized into two groups, high flow ratecyclone samplers (flow rate range 4.2 10 L/min) and mediumflow rate cyclone samplers (flow rate range 1.7 2.75 L/min).High flow rate samplers should be considered for workplaceswhere airbor
22、ne particle concentrations are low (for example,0.05, MMD*GSD 0.5 m):ubias51n(j51nbias2 biasj!2(8)where j labels one of the n (MMD, GSD) pairs.13.2.4.3 Details are presented in Research Report RR:D22-1033 for this standard and indicate that a respirable samplertype can be selected so that conservati
23、vely:ubias5 5% (9)13.2.4.4 This value is then taken as the bias uncertainty forthe purposes of this standard.NOTE 18If a sampler has desirable characteristics, but has biasuncertainty larger than 5 %, then its documented uncertainty replaces theabove value.NOTE 19Compliance agencies generally avoid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD45322015STANDARDTESTMETHODFORRESPIRABLEDUSTINWORKPLACEATMOSPHERESUSINGCYCLONESAMPLERS 采用 气旋 采样 工作

链接地址:http://www.mydoc123.com/p-517307.html