ASTM D4526-1996(2001)e1 Standard Practice for Determination of Volatiles in Polymers by Static Headspace Gas Chromatography《静液上气相色谱法测定聚合物中挥发物的标准实施规程》.pdf
《ASTM D4526-1996(2001)e1 Standard Practice for Determination of Volatiles in Polymers by Static Headspace Gas Chromatography《静液上气相色谱法测定聚合物中挥发物的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4526-1996(2001)e1 Standard Practice for Determination of Volatiles in Polymers by Static Headspace Gas Chromatography《静液上气相色谱法测定聚合物中挥发物的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4526 96 (Reapproved 2001)e1Standard Practice forDetermination of Volatiles in Polymers by Static HeadspaceGas Chromatography1This standard is issued under the fixed designation D 4526; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTESeveral sections were changed and added editorially in March 2001.1. Scope1.1 Headspace gas ch
3、romatography (GC) involves the de-termination of volatile components in a polymer solution bygas chromatography of a vapor phase in thermal equilibriumwith the sample matrix. Volatiles in finely ground insolublepolymers can also be determined with and without an extract-ing solvent.1.2 This practice
4、 provides two procedures:1.2.1 Procedure AAutomatic headspace analysis.1.2.2 Procedure BManual injection headspace analysis.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
5、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 6.NOTE 1There is no equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:D 4322 Test Method for Residual Acrylonitrile Mo
6、nomer inStyrene-Acrylonytrile Copolymers and Nitrile Rubber byHeadspace Gas Chromatography2E 260 Practice for Packed Column Gas Chromatography3E 355 Practice for Gas Chromatography Terms and Rela-tionships3E 594 Practice for Testing Flame Ionization Detectors Usedin Gas Chromatography33. Significanc
7、e and Use3.1 For various reasons, one may want to measure the levelof unreacted or residual monomer, water, or other volatilecomponents in a polymer sample.3.2 Volatiles of interest are often at trace concentrations.Headspace analysis is suited for determination of these tracecomponents which often
8、cannot be determined by conventionalgas chromatography because of sample decomposition orinterferences.3.3 For polymer analysis, sample treatment for headspaceanalysis is simpler than conventional gas chromatography,where precipitation steps may be required to prevent polymercontamination of the chr
9、omatographic column.3.4 This headspace practice will be able to determinequalitatively any component with sufficient vapor pressure. Itis capable of yielding semiquantitative results and can be usedfor relative comparisons between samples.4. Apparatus4.1 Gas Chromatograph, equipped with an appropria
10、tedetector and backflush valve.4.1.1 For Procedure A, an Automated Headspace Sampler,4including backflush capability, thermostated sample tray, andassociated accessories fulfill these requirements while provid-ing for automatic sequential sampling of headspace vapors.4.1.2 Procedure B requires the f
11、ollowing additional equip-ment:4.1.2.1 Constant-Temperature Bath, capable of maintaining90 6 1C.4.1.2.2 Gas-Tight Gas Chromatographic Syringes, whichcan be heated to 90C for sampling and injection.4.1.2.3 Valve, 6-port for backflush assembly.NOTE 2Appropriate detectors could include the following:(a
12、) Flame ionization (FID) for general organic volatiles,(b) Electron capture (EC) for halogenated species,(c) Nitrogen-phosphorous (NPD) for acrylonitrile,(d) Thermal conductivity (TC) for water, and(e) Hall electroconductivity or photoionization (PID) for vinyl chlo-ride.4.2 Chromatographic Columns:
13、1This practice is under the jurisdiction of ASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved Nov. 10, 1996. Published May 1997. Originallypublished as D 4526 85. Last previous edition D 4526 85 (1991)e1.2Annual Book
14、of ASTM Standards, Vol 08.02.3Annual Book of ASTM Standards, Vol 14.01.4Available from Perkin-Elmer Corp., Main Ave., Norwalk, CT 06856.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2.1 Packed Column AnalysisColumn packings5found
15、to be useful for residual monomers (for example, acrylonitrile,vinyl chloride) include Chromosorb or Porapak porous poly-mer packings, 0.4 % Carbowax 1500 liquid phase on CarbopakC support, or 0.19 % picric acid on Carbopak C support. Othercolumns can be used after it is determined that they give th
16、erequired resolution and accuracy for the component of interest.4.2.2 Capillary Column AnalysisChoose a column ca-pable of achieving the required resolution for the componentsof interest. For example, for acrylonitrile monomer, the columnof choice is a Quadrex 0072, 25m 3 0.32mm internaldiameter fus
17、ed silica.64.3 Integrator, recorder (5mV full scale), computing inte-grator or appropriate computer data station and softwarecapable of measuring and storing peak area data.4.4 Headspace Vials, septa, ring closures, and vial sealer.4.5 Analytical Balance, capable of weighing to 60.0001 g.4.6 Soap Fi
18、lm Flowmeter and Stopwatch, or other means ofmeasuring gas flow rates.4.7 Pressure Regulators for all required gas cylinders.4.8 Filter-Dryer Assemblies for each required gas cylinder.5. Reagents and Materials5.1 Solvent, Reagent Grade, or Best AvailableThe solventshould be free of interferences at
19、the retention time of volatilecompounds determined by this technique. Typical polymersolvents include water, dimethylformamide (DMF), dimethy-lacetamide (DMAC), propylene carbonate, ando-dichlorobenzene. These solvents are readily backflushedfrom most chromatographic columns.NOTE 3Volatile contamina
20、nts can often be removed by sparging withan inert gas for 24 to 48 h.5.2 Nitrogen, oxygen-free.NOTE 4Helium may also be used as the carrier gas and argon/methaneis the preferred carrier gas for use with electron capture detectors.5.3 Hydrogen, prepurified, for use with flame ionizationdetectors.5.4
21、Air, breathing or water pumped, for use with flameionization or nitrogen-phosphorus detectors.5.5 Standards, best available, for volatile compounds to beanalyzed using this technique.6. Safety Precautions6.1 Volatiles such as vinyl chloride and acrylonitrile shouldnot be released to the laboratory a
22、tmosphere. Prepare standardsand handle samples in a well-ventilated fume hood.6.2 Some of the recommended solvents are flammable.Dimethylacetamide is also absorbed through the skin, so avoidcontact.6.3 Be careful not to come into contact with heated chro-matograph parts, such as the detector, column
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD452619962001E1STANDARDPRACTICEFORDETERMINATIONOFVOLATILESINPOLYMERSBYSTATICHEADSPACEGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-517284.html