ASTM D4459-2012 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf
《ASTM D4459-2012 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4459-2012 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4459 12Standard Practice forXenon-Arc Exposure of Plastics Intended for IndoorApplications1This standard is issued under the fixed designation D4459; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers specific procedures and test condi-tions that are applicable for exposure of plastics in windowglass-fi
3、ltered xenon-arc devices in accordance with PracticesG151 and G155 for evaluating the stability of plastics intendedfor use in indoor applications.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this sta
4、ndard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this practice.2. Referenced Documents2.1 ASTM Standards:2D1729 Practice for Visual Appraisal of Colors and ColorDifferences of
5、 Diffusely-Illuminated Opaque MaterialsD2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD3980 Practice for Interlaboratory Testing of Paint andRelated Materials (Withdrawn 1998)3D4674 Practice forAccelerated Testing for Color Stabil
6、ity ofPlastics Exposed to Indoor Office EnvironmentsD5870 Practice for Calculating Property Retention Index ofPlasticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG113 Terminology Relating to Natural and Artificial Weath-ering Tests of Nonmetallic M
7、aterialsG141 Guide for Addressing Variability in Exposure Testingof Nonmetallic MaterialsG147 Practice for Conditioning and Handling of Nonmetal-lic Materials for Natural and Artificial Weathering TestsG151 Practice for Exposing Nonmetallic Materials in Accel-erated Test Devices that Use Laboratory
8、Light SourcesG155 Practice for Operating Xenon Arc Light Apparatus forExposure of Non-Metallic MaterialsG169 Guide for Application of Basic Statistical Methods toWeathering Tests3. Terminology3.1 The definitions in Terminology G113 are applicable tothis practice.4. Significance and Use4.1 This pract
9、ice is intended to simulate the effects pro-duced by exposure to solar radiation through glass. Thispractice uses exposure in a xenon-arc device equipped withwindow glass filters and operated in accordance with PracticesG151 and G155.NOTE 2Practice D4674 describes exposures in a device that uses aco
10、mbination of fluorescent “cool white” and ultraviolet (UV) lamps tosimulate the effects of exposures to indoor fluorescent light and windowglass filtered daylight.4.2 WarningVariation in results may be expected whenoperating conditions are varied within the accepted limits ofthis practice. Therefore
11、, all references to the use of this practicemust be accompanied by a report prepared in accordance withSection 9 that describes the specific operating conditions used.Refer to Practice G151 for detailed information on the caveatsapplicable to use of results obtained in accordance with thispractice.N
12、OTE 3Additional information on sources of variability and onstrategies for addressing variability in the design, execution and dataanalysis of laboratory accelerated exposure tests is found in Guide G141.4.3 Test results will depend upon the care that is taken tooperate the equipment in accordance w
13、ith Practice G155.Significant factors include regulation of line voltage, tempera-ture and humidity control, and condition and age of the lampsand filters.4.4 Reproducibility of test results between laboratories hasbeen shown to be good when the stability of materials is1This practice is under the j
14、urisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.50 on Durability of Plastics.Current edition approved Nov. 15, 2012. Published November 2012. Originallyapproved in 1985. Last previous edition approved in 2006 as D4459 - 06. DOI:10.1520/D4459-12.2For r
15、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is reference
16、d onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1evaluated in terms of performance ranking compared to othermaterials or to a control.4,5Therefore, expos
17、ure of a similarmaterial of known performance (a control) at the same time asthe test materials is strongly recommended. It is recommendedthat at least three replicates of each material be exposed toallow for statistical evaluation of results.5. Apparatus5.1 Use xenon-arc apparatus that conforms to
18、the require-ments defined in Practices G151 and G155.5.2 The spectral power distribution of the xenon-arc lampshall conform to the requirements described in Practice G155for a xenon-arc lamp with window glass filters.5.3 Unless otherwise specified, use a xenon-arc deviceequipped with a radiometer ca
19、pable of monitoring eithernarrow-band or broad-band irradiance incident on test speci-mens.6. Test Specimen6.1 The size and shape of specimens to be exposed will bedetermined by the specifications of the particular test methodused to evaluate the effects of the exposure on the specimens;the test met
20、hod shall be determined by the parties concerned.Where practical, it is recommended that specimens be sized tofit specimen holders and racks supplied with the exposureapparatus. Unless supplied with a specific backing as anintegral part of the test, specimens shall be mounted so thatonly the minimum
21、 specimen area required for support by theholder shall be covered. This unexposed surface must not beused as part of the test area.6.2 Unless otherwise specified, expose at least three repli-cate specimens of each test material and of the control material,if used.6.3 Follow the procedures described
22、in Practice G147 foridentification and conditioning and handling of specimens oftest, control, and reference materials prior to, during, and afterexposure.6.4 Do not mask the face of specimen for the purpose ofshowing on one panel the effects of various exposure times.Misleading results may be obtai
23、ned by this method, since themasked portion of the specimen is still exposed to temperatureand humidity cycles that in many cases will affect results.6.5 Since the thickness of a specimen may affect markedlythe results, thickness of test and control specimens shall bewithin 610 % of the nominal dime
24、nsions.NOTE 4This is especially important if changes in mechanical prop-erties are being investigated.6.6 Incident energy at the extremes of the specimen expo-sure area in older equipment may be only 70 % of that at thecenter. If the irradiance at any position within the exposure areais less than 90
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44592012STANDARDPRACTICEFORXENONARCEXPOSUREOFPLASTICSINTENDEDFORINDOORAPPLICATIONS 室内 要求 曝露 氙弧灯

链接地址:http://www.mydoc123.com/p-517122.html