ASTM D4459-2006 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf
《ASTM D4459-2006 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4459-2006 Standard Practice for Xenon-Arc Exposure of Plastics Intended for Indoor Applications《室内用要求曝露于氙弧灯的塑料标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4459 06Standard Practice forXenon-Arc Exposure of Plastics Intended for IndoorApplications1This standard is issued under the fixed designation D 4459; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers specific procedures and test condi-tions that are applicable for exposure of plastics in windowglass
3、-filtered xenon-arc devices in accordance with PracticesG 151 and G 155 for evaluating the stability of plasticsintended for use in indoor applications.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of thi
4、s standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this practice.2. Referenced Documents2.1 ASTM Standards:2D 1729 Practice for Visual Appraisal of Colors and ColorDifferen
5、ces of Diffusely-Illuminated Opaque MaterialsD 2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD 3980 Practice for Interlaboratoy Testing of Paint andRelated MaterialsD 4674 Practice for Accelerated Testing for Color Stabilityof Pla
6、stics Exposed to Indoor Office EnvironmentsD 5870 Practice for Calculating Property Retention Indexof PlasticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG113 Terminology Relating to Natural and ArtificialWeathering Tests of Nonmetallic MaterialsG
7、 141 Guide forAddressing Variability in Exposure Testingof Nonmetallic MaterialsG 147 Practice for Conditioning and Handling of Nonme-tallic Materials for Natural and Artificial Weathering TestsG 151 Practice for Exposing Nonmetallic Materials in Ac-celerated Test Devices that Use Laboratory Light S
8、ourcesG 155 Practice for Operating Xenon Arc Light Apparatusfor Exposure of Non-Metallic MaterialsG 169 Guide forApplication of Basic Statistical Methods toWeathering Tests3. Terminology3.1 The definitions in Terminology G113are applicable tothis practice.4. Significance and Use4.1 This practice is
9、intended to simulate the effects pro-duced by exposure to solar radiation through glass. Thispractice uses exposure in a xenon-arc device equipped withwindow glass filters and operated in accordance with PracticesG 151 and G 155.NOTE 2Practice D 4674 describes exposures in a device that uses acombin
10、ation of fluorescent “cool white” and ultraviolet (UV) lamps tosimulate the effects of exposures to indoor fluorescent light and windowglass filtered daylight.4.2 WarningVariation in results may be expected whenoperating conditions are varied within the accepted limits ofthis practice. Therefore, al
11、l references to the use of this practicemust be accompanied by a report prepared in accordance withSection 9 that describes the specific operating conditions used.Refer to Practice G 151 for detailed information on the caveatsapplicable to use of results obtained in accordance with thispractice.NOTE
12、 3Additional information on sources of variability and onstrategies for addressing variability in the design, execution and dataanalysis of laboratory accelerated exposure tests is found in Guide G 141.4.3 Test results will depend upon the care that is taken tooperate the equipment in accordance wit
13、h Practice G 155.Significant factors include regulation of line voltage, tempera-ture and humidity control, and condition and age of the burnerand filters.1This practice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.50 on Durability of
14、 Plastics.Current edition approved Sept. 1, 2006. Published October 2006. Originallyapproved in 1985. Last previous edition approved in 1999 as D 4459 - 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AST
15、MStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.4 Reproducibility of t
16、est results between laboratories hasbeen shown to be good when the stability of materials isevaluated in terms of performance ranking compared to othermaterials or to a control.3,4Therefore, exposure of a similarmaterial of known performance (a control) at the same time asthe test materials is stron
17、gly recommended. It is recommendedthat at least three replicates of each material be exposed toallow for statistical evaluation of results.5. Apparatus5.1 Use xenon-arc apparatus that conforms to the require-ments defined in Practices G 151 and G 155.5.2 The spectral power distribution of the xenon-
18、arc lampshall conform to the requirements described in Practice G 155for a xenon-arc lamp with window glass filters.5.3 Unless otherwise specified, use a xenon-arc deviceequipped with a radiometer capable of monitoring eithernarrow-band or broad-band irradiance incident on test speci-mens.6. Test Sp
19、ecimen6.1 The size and shape of specimens to be exposed will bedetermined by the specifications of the particular test methodused to evaluate the effects of the exposure on the specimens;the test method shall be determined by the parties concerned.Where practical, it is recommended that specimens be
20、 sized tofit specimen holders and racks supplied with the exposureapparatus. Unless supplied with a specific backing as anintegral part of the test, specimens shall be mounted so thatonly the minimum specimen area required for support by theholder shall be covered. This unexposed surface must not be
21、used as part of the test area.6.2 Unless otherwise specified, expose at least three repli-cate specimens of each test material and of the control material,if used.6.3 Follow the procedures described in Practice G 147 foridentification and conditioning and handling of specimens oftest, control, and r
22、eference materials prior to, during, and afterexposure.6.4 Do not mask the face of specimen for the purpose ofshowing on one panel the effects of various exposure times.Misleading results may be obtained by this method, since themasked portion of the specimen is still exposed to temperatureand humid
23、ity cycles that in many cases will affect results.6.5 Since the thickness of a specimen may affect markedlythe results, thickness of test and control specimens shall bewithin 610 % of the nominal dimensions.NOTE 4This is especially important if changes in mechanical prop-erties are being investigate
24、d.6.6 Incident energy at the extremes of the specimen expo-sure area in older equipment may be only 70 % of that at thecenter. If the irradiance at any position within the exposure areais less than 90 % of the peak irradiance, follow one of theprocedures outlined in Practice G 155 to ensure either e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便