ASTM D4424-2009 Standard Test Method for Butylene Analysis by Gas Chromatography《气相色谱法分析丁烯的标准试验方法》.pdf
《ASTM D4424-2009 Standard Test Method for Butylene Analysis by Gas Chromatography《气相色谱法分析丁烯的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4424-2009 Standard Test Method for Butylene Analysis by Gas Chromatography《气相色谱法分析丁烯的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4424 09Standard Test Method forButylene Analysis by Gas Chromatography1This standard is issued under the fixed designation D4424; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the gas chromatographic analy-sis of commercial butylenes, butylene concentrates, andbutane-butylene mixtures.1.2 This te
3、st method does not cover high-purity butene-1 orhigh-purity isobutene streams, or both. However, it is possiblethat one or more columns listed in Appendix X3 may becapable of the separation necessary for high-purity analyses.1.3 This test method is designed to cover the componentslisted below at abo
4、ut 0.05 % or greater. It is not intended fortrace hydrocarbon analysis. Components to be determined are:propane, propylene, isobutane, n-butane, butene-1, isobutene,trans-butene-2, cis-butene-2, 1,3-butadiene, isopentane,n-pentane.1.4 The values stated in SI units are to be regarded as thestandard.
5、The values stated in inch-pound units are for infor-mation only.1.5 This standard does not purport to address all of thesafety concerns associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of
6、 regulatorylimitations prior to use. For specific warning statements, see5.3.1.2. Referenced Documents2.1 ASTM Standards:2E260 Practice for Packed Column Gas Chromatography3. Summary of Test Method3.1 The sample is separated in a gas chromatograph systemusing a packed chromatographic column with eit
7、her helium orhydrogen as the carrier gas. The separated components of thesample are detected by either a thermal conductivity detector orby a flame ionization detector. Calibration data are obtained byusing either relative response factors or by using a standardcalibration blend.4. Significance and
8、Use4.1 This test method could be used to determine butylenestream composition for custody transfer payments. It is alsocapable of providing data necessary to evaluate processingrequirements in an operating plant.5. Apparatus5.1 ChromatographAny chromatographic instrumenthaving either a thermal condu
9、ctivity or flame ionizationdetector with an overall sensitivity sufficient to detect at least0.05 % of each of the components listed in 1.3.5.2 DetectorEither a thermal conductivity or flame ion-ization detector may be used.5.3 Sample ValveEither a constant-volume gas samplingvalve or a liquid sampl
10、ing valve may be used. If a gas samplingvalve is used, greater care must be taken to ensure that thevaporized butylenes that are injected into the chromatographare a true representation of the sample.5.3.1 If the liquid sample valve is used, the sample cylindermust be pressured up to at least 1100 k
11、Pa (160 psig) with aninert gas, such as nitrogen or helium. (WarningCompressedgas under high pressure. Gas reduces oxygen available forbreathing.) Also a valve must be installed in the purge linedownstream of the liquid sample valve to ensure the butylenessample in the sampling valve is entirely in
12、the liquid phaseprior to injection into the column. (WarningExtremelyflammable liquefied gas under pressure. Vapor reduces oxygenavailable for breathing.)1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of Subcommi
13、tteeD02.D0.04 on C4 Hydrocarbons.Current edition approved July 15, 2009. Published November 2009. Originallyapproved in 1984. Last previous edition approved in 2001 as D442490(2001)1.DOI: 10.1520/D4424-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S
14、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 ColumnAny chromatographic column may
15、be used,providing the components listed in the scope can be separatedsufficiently for the accurate determination of component con-centration. Resolution between peaks must afford a resolutionsuch that the depth of the valleys between peaks are no lessthan 50 % of the peak height of the lesser compon
16、ent. A list ofsatisfactory columns is given in Appendix X3.5.5 RecorderA recorder with a full-scale response of 2 sor less and a maximum rate of noise of 60.3 % of full scale.6. Preparation of Apparatus6.1 Set up the chromatograph in accordance with the manu-facturers recommendations. Install the an
17、alytical column andadjust the carrier gas flow and column temperature so that thecomponents will elute within the time desired for the analysis.7. Calibration7.1 A standard blend containing the components to beanalyzed may be either made or purchased from a commercialsource. Inject the calibration b
18、lend under identical conditionsas will be used for the samples. Record the chromatogram andcalculate the factors to be used for analysis by using the peakareas as measured by either manual, mechanical, or electronicmeans.7.2 Relative response factors may be used if they areavailable.NOTE 1Practice E
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44242009STANDARDTESTMETHODFORBUTYLENEANALYSISBYGASCHROMATOGRAPHY 色谱 分析 丁烯 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517018.html