ASTM D4423-2010 Standard Test Method for Determination of Carbonyls In C4 Hydrocarbons《C4烃中羰基的标准试验方法》.pdf
《ASTM D4423-2010 Standard Test Method for Determination of Carbonyls In C4 Hydrocarbons《C4烃中羰基的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4423-2010 Standard Test Method for Determination of Carbonyls In C4 Hydrocarbons《C4烃中羰基的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4423 10Standard Test Method forDetermination of Carbonyls in C4Hydrocarbons1This standard is issued under the fixed designation D4423; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of carbonyls(ketones and aldehydes) in C4hydrocarbons. This test methodwas tested on polymerizatio
3、n-grade 1,3-butadiene.1.2 The applicable range for this test method is 0 to50 mg/kg carbonyls calculated as acetaldehyde.1.3 Other C4hydrocarbons and their mixtures besidespolymerization-grade 1,3-butadiene could be tested using thissame test method. However, the precision section of this testmethod
4、 covers only carbonyls in applicable range as listed in1.2, as found in polymerization-grade 1,3-butadiene.1.4 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous t
5、o health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling
6、mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, as
7、sociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D484 Specification for Hydrocarbon Dry Cleaning Sol-ven
8、ts3D1193 Specification for Reagent WaterE1 Specification for ASTM Liquid-in-Glass Thermometers3. Summary of Test Method3.1 A measured amount of sample is added to an alcoholichydroxylamine hydrochloride solution that has been adjustedto a given coloration using either alcoholic acid or base. Thecarb
9、onyls will react with the hydroxylamine hydrochloridereleasing an equivalent amount of hydrochloric acid which isthen back-titrated to the original coloration.Ablank containingonly methanol and sample is titrated and the samples resultsare calculated using the blank adjustment. Results are reporteda
10、s milligrams per kilogram carbonyls as acetaldehyde.4. Significance and Use4.1 The determination of the carbonyl content ofpolymerization-grade 1,3-butadiene is necessary, since in somepolymerization reactions, the presence of carbonyls in excessover some specified amount can have a deleterious effe
11、ct uponthe polymer properties or the reaction itself, or both.5. Apparatus5.1 Bunsen ValvesAdevice constructed so that when usedwith an Erlenmeyer flask, the sample vapors can exit the flaskwhile protecting the flasks liquid contents. See Fig. 1 fordetails.5.2 Cooling CoilPrepare a cooling coil by w
12、inding about10 to 15 cm of seamless copper tubing (about 6-mm diameter)on a short length of pipe (about 1.5 to 2.0-cm diameter),allowing sufficient length of tubing at the end of the coil toconnect it to the sample source. Attach a valve at a point thatwould not extend more than 8 cm above the surfa
13、ce of thecooling bath liquid. To the valve, attacha6to8cmlengthpiece of tubing bent downward so that the hydrocarbon liquidcan be directed into the receiving container.5.3 Dewar FlaskThe Dewar flask must be of sufficientvolume to completely immerse the main portion of the cooling1This test method is
14、 under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.04 on C4 Hydrocarbons.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1984. Last previous edition approved in 2006 as D442300(2006
15、).DOI: 10.1520/D4423-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version
16、 of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.coil except for the extremities necessary for receiving anddelivering the sample through the coil.5.4 Erlenmeyer Flasks, 250-mL
17、 capacity.5.5 Volumetric Flasks, 1-L capacity. These flasks should beClass A glassware.5.6 Graduated Cylinders100-mL capacity, glass cylin-ders, graduated in 1 or 2-mL divisions.5.7 Microburets, 2.00 or 5.00-mL capacity. The microburetsshould be ClassAglassware with 0.01 or 0.02-mL divisions orless.
18、 It is advisable to have the burets tip end equipped with asyringe needle to dispense very small drops of titrant.5.8 Sample CylindersThese should be of sufficient vol-ume to give the required amount of sample for testing.Stainless steel cylinders equipped with needle valves should beused. It is sug
19、gested that a 500-mL-capacity cylinder be theminimum size to be used for butadiene.5.9 ThermometerFor observing temperatures below45C. The Low Cloud and Pour Point Thermometer, con-forming to the requirements for ASTM Thermometer 6C, asprescribed in Specification E1, is satisfactory. Thermometer 6Ch
20、as a range from 80 to +20C. Temperature measuringdevices that cover the temperature range of interest, such as theASTM 1C thermometer, or liquid-in-glass thermometers, ther-mocouples, or platinum resistance thermometers that provideequivalent or better accuracy and precision may be used.6. Reagents
21、and Materials6.1 Purity of ReagentsReagent grade chemicals should beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.4Other grade
22、s may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean Type II reagent waterconforming to Specific
23、ation D1193.6.3 Alcoholic Hydrochloric Acid (0.05 N)Dilute 4.2 mLof concentrated hydrochloric acid (WarningPoison. Corro-sive. May be fatal if swallowed. Liquid and vapor cause severeburns. Harmful if inhaled.) to volume with anhydrous methanolin a 1-L volumetric flask. Use the alcoholic 0.05 N pota
24、ssiumhydroxide solution to standardize the HCl solution.6.4 Alcoholic Hydroxylamine HydrochlorideDissolve35.0 g of hydroxylamine hydrochloride (WarningMay beirritating to skin, eyes, or mucous membranes. Harmful ifinhaled.) in 3.5 L of anhydrous methanol. (WarningFlammable. Vapor harmful. May be fat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44232010STANDARDTESTMETHODFORDETERMINATIONOFCARBONYLSINC4HYDROCARBONSC4 羰基 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517015.html