ASTM D4291-2004(2017) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《废机油中微量乙二醇的标准试验方法》.pdf
《ASTM D4291-2004(2017) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《废机油中微量乙二醇的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4291-2004(2017) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《废机油中微量乙二醇的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4291 04 (Reapproved 2017)Standard Test Method forTrace Ethylene Glycol in Used Engine Oil1This standard is issued under the fixed designation D4291; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of ethyleneglycol as a contaminant in used engine oil. This test method isdesigned t
3、o quantitate ethylene glycol in the range from5 mass ppm to 200 mass ppm.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practice
4、s and deter-mine the applicability of regulatory limitations prior to use.For specific warning statements, see Section 6.NOTE 1A qualitative determination of glycol-base antifreeze isprovided in Test Methods D2982. Procedure A is sensitive to about100 ppm.1.3 This international standard was develope
5、d in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documen
6、ts2.1 ASTM Standards:2D1193 Specification for Reagent WaterD2982 Test Methods for Detecting Glycol-Base Antifreezein Used Lubricating OilsD4057 Practice for Manual Sampling of Petroleum andPetroleum Products3. Summary of Test Method3.1 The sample of oil is extracted with water and theanalysis is per
7、formed on the water extract. A reproduciblevolume of the extract is injected into a gas chromatographusing on-column injection and the eluting compounds aredetected by a flame ionization detector. The ethylene glycolpeak area is determined and compared with areas obtainedfrom the injection of freshl
8、y prepared known standards.4. Significance and Use4.1 Leakage of aqueous engine coolant into the crank caseweakens the ability of the oil to lubricate. If ethylene glycol ispresent, it promotes varnish and deposit formation. This testmethod is designed for early detection to prevent coolant fromaccu
9、mulating and seriously damaging the engine.5. Apparatus5.1 Gas ChromatographAny gas chromatographequipped with the following:5.1.1 Flame Ionization Detector, capable of operating con-tinuously at a temperature equivalent to the maximum columntemperature employed, and connected to the column so as to
10、avoid any cold spots.5.1.2 Sample Inlet System, providing for on-column injec-tion and capable of operating continuously at a temperatureequivalent to the maximum column temperature employed.5.2 RecorderRecording potentiometer with a full-scaleresponse time of 2 s or less may be used.5.3 Columns1.2
11、m by 6.4 mm (4 ft by14 in.) copper tubepacked with 5 % by mass Carbowax 20-M liquid phase on30/60 mesh Chromosorb T solid support. As an alternative, afused silica capillary column, 15 m long with a 0.53 mm IDand 2.0 micron film thickness of a bonded polyethylene glycolcan be used.5.4 IntegratorManu
12、al, mechanical, or electronic integra-tion is required to determine the peak area. However, bestprecision and automated operation can be achieved withelectronic integration.5.5 CentrifugeRCF 600 minimum and centrifuge tubeswith stoppers.5.6 SyringeA microsyringe, 10 L is needed for sampleintroductio
13、n.5.7 Pasteur Pipets.5.8 Vials, 2 mL, with crimped septum caps.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.04.0L on Gas Chromatography Methods.Current edition approved Oct. 1,
14、 2017. Published November 2017. Originallyapproved in 1983. Last previous edition approved in 2013 as D4291 04 (2013).DOI: 10.1520/D4291-04R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
15、lume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on sta
16、ndardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.16. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in
17、all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.3Other grades may be used,provided it is first ascertained that the reagent is of suffic
18、ientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type II of Specification D1193.6.3 Air and Hydrogen(WarningThe air supply may befrom a cylin
19、der under high pressure. Hydrogen is an extremelyflammable gas under pressure.)6.4 Calibration MixturesA minimum of three mixtures ofwater and ethylene glycol are prepared to cover the range from5 mass ppm to 200 mass ppm. Prepare one blend of approxi-mately 2000 mass ppm ethylene glycol in water to
20、 provide foraccurate weighing; then, prepare dilutions of that solution.6.5 Carrier Gas, helium or nitrogen may be used with theflame ionization detector. (WarningHelium and nitrogen arecompressed gases under high pressure.)6.6 Ethylene Glycol, 99 % by mass pure.6.7 n-Hexane, 99 mol % pure. (Warning
21、n-Hexane isextremely flammable, harmful if inhaled, may produce nervecell damage.)6.8 Liquid Phase and Solid Support, 5 % by mass Carbowax20-M liquid phase on 30/60 mesh Chromosorb T solid support.6.9 Tubing, 6.4 mm (14 in.) in outside diameter, 1.2 m (4 ft)long of copper.6.10 Water, deionized or di
22、stilled.7. Preparation of Apparatus7.1 Packed Column PreparationIf a packed column isused, prepare it using the following steps:7.1.1 Prepare the packing, 5 % by mass Carbowax 20-Mliquid phase on 30/60 mesh Chromosorb T solid support, byany satisfactory method used in the practice of gas chromatog-r
23、aphy.NOTE 2Care should be taken in handling Chromosorb T solid supportbecause of its static charge and softness. Chilling may be helpful inimproving its handling properties.7.1.2 Add the prepared packing to the copper tubing usingonly gentle tapping. Do not use vacuum or mechanical vibra-tion to pac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD429120042017STANDARDTESTMETHODFORTRACEETHYLENEGLYCOLINUSEDENGINEOIL 机油 微量 乙二醇 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-516728.html