ASTM D4275-2002 Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene-Vinyl Acetate (EVA) Copolymers By Gas Chromatography《.pdf
《ASTM D4275-2002 Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene-Vinyl Acetate (EVA) Copolymers By Gas Chromatography《.pdf》由会员分享,可在线阅读,更多相关《ASTM D4275-2002 Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene-Vinyl Acetate (EVA) Copolymers By Gas Chromatography《.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4275 02Standard Test Method forDetermination of Butylated Hydroxy Toluene (BHT) inPolymers of Ethylene and EthyleneVinyl Acetate (EVA)Copolymers By Gas Chromatography1This standard is issued under the fixed designation D 4275; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a procedure for the
3、 determi-nation of butylated hydroxy toluene (BHT) (2,6-di-t-butyl-4-methyl-hydroxybenzene) in polymers of ethylene andethylene-vinyl acetate (EVA) copolymers by solvent extractionfollowed by gas chromatographic analysis. Detection of thecompound is achieved by flame ionization, and quantitativeanal
4、ysis is obtained by use of internal or external standards, asdescribed in Practices E 260, E 355, and E 594.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety conc
5、erns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 9.NOTE 1There is no simil
6、ar or equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:D 4968 Guide for Annual Review of Test Methods andSpecifications for Plastics2E 260 Practice for Packed Column Gas Chromatography2E 355 Practice for Gas Chromatography Terms and Rela-tionships3E 380 Practice for Use of the Inter
7、national System of Units(SI) (the Modernized Metric System)4E 594 Practice for Testing Flame Ionization Detectors Usedin Gas Chromatography3E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method33. Terminology3.1 DefinitionsUnits and symbols used in this te
8、st methodare those recommended in Practice E 380. Chromatographicterms and relationships are as described in Practice E 355.3.2 Abbreviations:Abbreviations:3.2.1 BHTButylated hydroxy toluene (2,6-di-tert-butyl-4-methyl-hydroxybenzene).3.2.2 MMMethyl myristate.3.2.3 EVAEthylene-vinyl acetate copolyme
9、rs.3.2.4 LDPELow-density polyethylene.3.2.5 HDPEHigh-density polyethylene.4. Summary of Test Method4.1 The BHT from a finely ground polymer sample isextracted by shaking or refluxing with cyclohexane or isopro-panol that may contain an internal standard. A known volumeof this extract is injected int
10、o a gas chromatographic columnpacked with a liquid-coated solid support. Passing through thiscolumn in a stream of carrier gas, BHT is separated from theextraction solvent and other components. Responses of BHTand any internal standard are measured by a flame ionizationdetector. This signal is recor
11、ded to indicate the relativeconcentration and retention time of BHT.5. Significance and Use5.1 Separation and identification of stabilizers used in themanufacture of polyethylene are necessary in order to correlateperformance properties with polymer composition.5.2 The BHT extraction procedure is ma
12、de effective by theinsolubility of the polymer sample in solvents generally usedfor gas chromatographic analysis.6. Interferences6.1 Any material eluting at or near the BHT or MMretention times will cause erroneous results. Prior to extraction,solvent blanks should be analyzed to confirm the absence
13、 ofinterfering peaks.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved Aug. 10, 2002. Published October 2002. Originallypublished as D 4275 83. Last previous edition D 42
14、75 96.2Annual Book of ASTM Standards, Vol 08.03.3Annual Book of ASTM Standards, Vol 14.02.4Discontinued; see 1997 Annual Book of ASTM Standards , Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Apparatus7.1 Reflux Extrac
15、tion, consisting of 250-mL round-bottomflask with condenser and heating mantle to fit.7.2 Wiley Mill, with 10 and 20-mesh screens.7.3 Wrist-Action Shaker.7.4 Gas Chromatograph, equipped with a flame ionizationdetector.7.5 Chromatographic Column, 3.2-mm outside diametertimes 1.8 m packed with 20 % UC
16、W-98 on 80/100 meshChromosorb P, a similar packed column, or an equivalentcapillary column, such as a HP-1 or DB-1.7.6 Integrator, capable of measuring the net peak area onthe back side of a solvent peak.7.7 Gas Chromatographic Syringe,10L.7.8 Analytical Balance, capable of weighing to 60.0001 g.7.9
17、 Pressure Regulators, for all required gas cylinders.7.10 Filter-Dried Assemblies, for each required gas cylin-der.7.11 Soap Film Flowmeter and Stopwatch, or other meansof measuring gas flow rates.8. Reagents and Materials8.1 Cyclohexane, reagent grade.8.2 Isopropyl Alcohol, reagent grade.8.3 Methyl
18、 Myristate,599+%, boiling point 323C (internalstandard).8.4 Butylated Hydroxy Toluene, food grade (2,6-di-tert-butyl-4-methyl-hydroxybenzene).8.5 Hydrogen Cylinder, prepurified.8.6 Nitrogen Cylinder, prepurified, oxygen-free for carriergas.NOTE 2Helium may also be used as the carrier gas.8.7 Air, br
19、eathing or water-pumped.9. Safety Precautions9.1 Cyclohexane and isopropyl alcohol are flammable. Thisextraction procedure should be carried out in a fume hood.10. Preparation of Gas Chromatograph10.1 Install the chromatographic column and conditionovernight at 200C with carrier gas flow rate of 35
20、mL/min. Donot connect the exit end of the column to the detector duringthis conditioning period. Turn off hydrogen and air flows to thedetector while the column is disconnected.10.2 Connect the exit end of the column to the detector. Setoptimum hydrogen and air flow rates for the detector asspecifie
21、d for the chromatograph model in use, or as determinedexperimentally.10.3 Set chromatograph temperatures as follows:10.3.1 Oven (chromatographic column), 160C.10.3.2 Injection block, 220C.10.3.3 Detector block, 240C.11. Calibration by Internal Standard11.1 Weigh a syringe containing approximately 80
22、 mg ofmethyl myristate.11.2 Transfer syringe contents to a 2-L volumetric flask andimmediately reweigh the syringe (60.1 mg).11.3 Dilute to volume with extraction solvent (cyclohexaneor isopropyl alcohol) and store in a tightly stoppered flask.11.4 Weigh and transfer 20 6 0.1 mg of BHT into a 500-mL
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42752002STANDARDTESTMETHODFORDETERMINATIONOFBUTYLATEDHYDROXYTOLUENEBHTINPOLYMERSOFETHYLENEANDETHYLENEVINYLACETATEEVACOPOLYMERSBYGASCHROMATOGRAPHYPDF

链接地址:http://www.mydoc123.com/p-516685.html