ASTM D4096-1991(2009) Standard Test Method for Determination of Total Suspended Particulate Matter in the Atmosphere (High-Volume Sampler Method)《空气中悬浮粒子的标准试验方法(大容器取样器法)》.pdf
《ASTM D4096-1991(2009) Standard Test Method for Determination of Total Suspended Particulate Matter in the Atmosphere (High-Volume Sampler Method)《空气中悬浮粒子的标准试验方法(大容器取样器法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4096-1991(2009) Standard Test Method for Determination of Total Suspended Particulate Matter in the Atmosphere (High-Volume Sampler Method)《空气中悬浮粒子的标准试验方法(大容器取样器法)》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4096 91 (Reapproved 2009)Standard Test Method forDetermination of Total Suspended Particulate Matter in theAtmosphere (HighVolume Sampler Method)1This standard is issued under the fixed designation D 4096; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides for sampling a large volumeof atmosphere,
3、1600 to 2400 m3(55 000 to 85 000 ft3), bymeans of a high flow-rate vacuum pump at a rate of 1.13 to1.70 m3/min (40 to 60 ft3/min) (1, 2, 3 and 4).21.2 This flow rate allows suspended particles having diam-eters of less than 100 m (stokes equivalent diameter) to becollected. However, the collection e
4、fficiencies for particleslarger than 20 m decreases with increasing particle size and itvaries widely with the angle of the wind with respect to theroof ridge of the sampler shelter and with increasing speed (5).When glass fiber filters are used, particles within the size rangeof 100 to 0.1 m diamet
5、ers or less are ordinarily collected.1.3 The upper limit of mass loading will be determined byplugging of the filter medium with sample material, whichcauses a significant decrease in flow rate (see 6.4). For verydusty atmospheres, shorter sampling periods will be necessary.The minimum amount of par
6、ticulate matter detectable by thismethod is 3 mg (95 % confidence level). When the sampler isoperated at an average flow rate of 1.70 m3/min (60 ft3/min) for24 h, this is equivalent to 1 to 2 g/m3(3).1.4 The sample that is collected may be subjected to furtheranalyses by a variety of methods for spe
7、cific constituents.1.5 Values stated in SI units shall be regarded as thestandard. Inch-pound units are shown for information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establi
8、sh appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3631 Test Methods for Measuring Surface AtmosphericPressureE1 Specificati
9、on for ASTM Liquid-in-Glass Thermometers2.2 Other Documents:EPA-600/9-76-005 Quality Assurance Handbook for AirPollution Measurement Systems, Vol I, Principles (De-cember 1984 Rev.)4EPA-600/4-77-027a Quality Assurance Handbook for AirPollution Measurement Systems, Vol II, Ambient AirSpecific Methods
10、43. Terminology3.1 DefinitionsFor definitions of other terms used in thistest method, refer to Terminology D 1356.3.2 Descriptions of Terms:3.2.1 absolute filtera filter or filter medium of ultra-highcollection efficiency for very small particles (submicrometresize) so that essentially all particles
11、 of interest or of concern arecollected. Commonly, the efficiency is in the region of 99.95 %or higher for a standard aerosol of 0.3-m diameter (seePractice D 2986).3.2.2 Hi-Vol (The High-Volume Air Sampler)a device forsampling large volumes of an atmosphere, collection of thecontained particulate m
12、atter by filtration, and consisting of ahigh-capacity air mover, a filter to collect suspended particles,and means for measuring, or controlling, or both, the flow rate.3.2.3 primary flow-rate standarda device or means ofmeasuring flow rate based on direct primary observations, suchas time and physi
13、cal dimensions.3.2.4 secondary flow-rate standardA flow-rate-measuringdevice, such as an orifice meter, that has been calibratedagainst a primary standard.3.2.5 spirometera displacement gasometer consisting ofan inverted bell resting upon or sealed by liquid (or othermeans) and capable of showing th
14、e amount of gas added to orwithdrawn from the bell by the displacement (rise or fall) of thebell.1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.03 on AmbientAtmospheres and Source Emissions.Current edition approved
15、 March 1, 2009. Published March 2009. Originallyapproved in 1982. Last previous edition approved in 2003 as D 4096 91 (2003).2The boldface numbers in parentheses refer to the list of references at the end ofthis practice.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
16、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from U.S. Environmental Protection Agency, Environmental Moni-toring Systems Laboratory, QualityAssurance Division, Research Tria
17、ngle Park, NC27711. Attn: Distribution Record System.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.6 working flow-rate standarda flow rate measuringdevice, such as an orifice meter, that has been calibratedagainst a secondary f
18、low-rate standard. The working flow-ratestandard is used to calibrate a flow measuring or flow rateindicating instrument.3.2.7 constant flow high-volume samplera high volumesampler that is equipped with a constant flow control device.4. Summary of Test Method4.1 This test method describes typical eq
19、uipment, opera-tional procedures, and a means of calibration of the equipmentusing an orifice flowrate meter. (See also Annex A1.)4.2 Air is drawn into a covered housing and through a filterby means of a high-flow-rate air mover, so that particulatematerial collects on the filter surface.4.3 The amo
20、unt of particulate matter accumulated on thefilter over a specified period of time is measured by weighinga preweighed filter after exposure. The flow rate of air sampledis measured over the test period. The result is expressed interms of particulate mass collected (or loading) per unit volumeof air
21、 sampled, usually as micrograms per cubic metre (g/m3).The volume of air sampled is recorded by measurement of thedevice flow rate(s).4.4 The volume of air sampled is determined by means of aflow-rate indicator. The instrument flow-rate indicator is cali-brated against a reference orifice meter. The
22、 latter is a workingstandard which, in turn, has been calibrated against a secondaryflow meter certified by the U.S. National Institute of Standardsand Technology.4.5 Airborne particulate matter retained on the filter may beexamined or analyzed by a variety of methods. Specificprocedures are not inc
23、luded in this method but are the subjectof separate standard methods.5. Significance and Use5.1 The Hi-Vol sampler is commonly used for the collectionof the airborne particulate component of the atmosphere. Somephysical and chemical parameters of the collected particulatematter are dependent upon th
24、e physical characteristics of thecollection system and the choice of filter media. A variety ofoptions available for the Hi-Vol sampler give it broad versa-tility and allow the user to develop information about the sizeand quantity of airborne particulate material and, using subse-quent chemical ana
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD409619912009STANDARDTESTMETHODFORDETERMINATIONOFTOTALSUSPENDEDPARTICULATEMATTERINTHEATMOSPHEREHIGHVOLUMESAMPLERMETHOD

链接地址:http://www.mydoc123.com/p-516264.html