《ASTM D4095-1997(2002) Standard Practice for Use of the Refractometer for Determining Nonvolatile Matter (Total Solids) in Floor Polishes《测定地板擦亮剂中的不挥发物质(总的固体物质)用折射计的使用规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4095-1997(2002) Standard Practice for Use of the Refractometer for Determining Nonvolatile Matter (Total Solids) in Floor Polishes《测定地板擦亮剂中的不挥发物质(总的固体物质)用折射计的使用规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4095 97 (Reapproved 2002)Standard Practice forUse of the Refractometer for Determining Nonvolatile Matter(Total Solids) in Floor Polishes1This standard is issued under the fixed designation D 4095; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the use of a refractometer fordetermining the nonvolat
3、ile matter (total solids) in floorpolishes. This practice is also applicable to resin solutions andwax emulsions used in floor polishes.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to es
4、tablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1218 Test Method for Refractive Index and RefractiveDispersion of Hydrocarbon Liquids2D 2834 Test Method for Nonvolatile Matter (Total
5、Solids)in Water-Emulsion Floor Polishes, Solvent-Based FloorPolishes, and Polymer-Emulsion Floor Polishes33. Summary of Practice3.1 Solids (nonvolatile matter) and refractive index are usedas the basis for preparing curves that allow the use of refractiveindex as a fast, accurate means for determini
6、ng solids in floorpolishes, resin solutions, and wax emulsions.4. Significance and Use4.1 Solids (nonvolatile matter) determinations of polishes,resin solutions, and wax emulsions take 2 to4hinaccordancewith Test Method D 2834, not counting preparation time.4.2 Curves of solids/refractive index prov
7、ide a means fordetermining solids in a matter of minutes.4.3 This practice is particularly useful for quality controland in process control for the production of polishes and polishcomponents.5. Apparatus5.1 RefractometerAn instrument capable of reading tofour decimal places.5.2 Water Bath, or other
8、 means of controlling the tempera-ture of the refractometer prisms.6. Procedure6.1 Determine the nonvolatile matter in the polish, resin, orwax emulsion in accordance with Test Method D 2834 using aminimum of three and preferably four replicates. Record thearithmetic average.6.2 Adjust prism tempera
9、ture of the refractometer to 25Cthrough the use of a water bath. Temperatures of 20C and30C are also commonly used for refractive index work. Anyconvenient temperature may be used as long as that tempera-ture is used consistently.6.3 Standardize the refractometer using the procedure inTest Method D
10、1218 or according to the refractometer manu-facturers instructions. In either case standard reference liquidsshould be used.6.4 Determine the refractive index of the process water usedfor preparation of the polish, resin, or wax emulsion accordingto the procedure in Test Method D 1218.6.5 Determine
11、the refractive index of the same sample ofpolish, resin solution, or wax emulsion from 6.1 according tothe procedure in Test Method D 1218. (Take multiple readingsand record the arithmetic average.)6.6 Plot a curve of refractive index versus solids on standard(20 by 20/in.) graph paper.6.6.1 Use zer
12、o (0 %) solids and the refractive index of theprocess water as the origin.6.6.2 Plot the solids from 6.1 and the refractive index from6.5 as the second point. Draw a line connecting the origin to thesecond point. Curves, thus produced for polishes, resin solu-tions, and wax emulsions are usually str
13、aight lines. Verificationmust be made by careful dilution (by weight) of the samplewith the process water; determine the refractive index of thediluted sample that should fall on the curve at the calculatedsolids.6.6.3 Curves should be checked periodically by determiningsolids in accordance with Tes
14、t Method D 2834 to make sure the1This practice is under the jurisdiction of ASTM Committee D21 on Polishesand is the direct responsibility of Subcommittee D21.03 on Chemical and PhysicalTesting.Current edition approved Sept. 10, 1997. Published June 1998. Originallypublished as D 4095 82. Last previ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD409519972002STANDARDPRACTICEFORUSEOFTHEREFRACTOMETERFORDETERMININGNONVOLATILEMATTERTOTALSOLIDSINFLOORPOLISHES

链接地址:http://www.mydoc123.com/p-516260.html