ASTM D4052-2015 Standard Test Method for Density Relative Density and API Gravity of Liquids by Digital Density Meter《采用数字密度计测定液体密度 相对密度和API比重的标准试验方法》.pdf
《ASTM D4052-2015 Standard Test Method for Density Relative Density and API Gravity of Liquids by Digital Density Meter《采用数字密度计测定液体密度 相对密度和API比重的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4052-2015 Standard Test Method for Density Relative Density and API Gravity of Liquids by Digital Density Meter《采用数字密度计测定液体密度 相对密度和API比重的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4052 11D4052 15Standard Test Method forDensity, Relative Density, and API Gravity of Liquids byDigital Density Meter1This standard is issued under the fixed designation D4052; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This test me
3、thod covers the determination of the density, relative density, and API Gravity of petroleum distillates andviscous oils that can be handled in a normal fashion as liquids at the temperature of test, utilizing either manual or automatedsample injection equipment. Its application is restricted to liq
4、uids with total vapor pressures (see Test Method D5191) typicallybelow 100 kPa 100 kPa and viscosities (see Test Method D445 or D7042) typically below about 15 000 mm15 000 mm2/s at thetemperature of test. The total vapor pressure limitation however can be extended to 100 kPa 100 kPa provided that i
5、t is firstascertained that no bubbles form in the U-shaped, oscillating tube, which can affect the density determination. Some examples ofproducts that may be tested by this procedure include: gasoline and gasoline-oxygenate blends, diesel, jet, basestocks, waxes, andlubricating oils.1.1.1 Waxes and
6、 highly viscous samples were not included in the 1999 interlaboratory study (ILS) sample set that was used todetermine the current precision statements of the method, since all samples evaluated at the time were analyzed at a testtemperature of 15C.15 C. Wax and highly viscous samples require a temp
7、erature cell operated at elevated temperatures necessaryto ensure a liquid test specimen is introduced for analysis. Consult instrument manufacturer instructions for appropriate guidanceand precautions when attempting to analyze wax or highly viscous samples. Refer to the Precision and Bias section
8、of the methodand Note 8 for more detailed information about the 1999 ILS that was conducted.1.2 In cases of dispute, the referee method is the one where samples are introduced manually as in 6.3 or 6.4, as appropriatefor sample type.1.3 This test method should not be applied to samples so dark in co
9、lor that the absence of air bubbles in the sample cell cannotbe established with certainty. For the determination of density in crude oil samples use Test Method D5002.1.4 The values stated in SI units are regarded as the standard, unless stated otherwise, such as the “torr” units of pressure inothe
10、rwise. Eq 1. The accepted units of measure for density are grams per millilitre (g/mL) or kilograms per cubic metre (kg/m3).1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish app
11、ropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific warning statements, see 7.4, 7.5, and 10.3.2. Referenced Documents2.1 ASTM Standards:2D287 Test Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method
12、)D445 Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)D1193 Specification for Reagent WaterD1250 Guide for Use of the Petroleum Measurement TablesD1298 Test Method for Density, Relative Density, or API Gravity of Crude Petroleum and Liquid
13、Petroleum Products byHydrometer MethodD4057 Practice for Manual Sampling of Petroleum and Petroleum Products1 This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.04.0D on Phy
14、sical and Chemical Methods.Current edition approved Oct. 15, 2011Dec. 15, 2015. Published December 2011February 2016. Originally approved in 1981. Last previous edition approved in 20092011as D4052D4052 11.09. DOI: 10.1520/D4052-11.10.1520/D4052-15.2 For referencedASTM standards, visit theASTM websi
15、te, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication
16、 of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be conside
17、red the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D4177 Practice for Automatic Sampling of Petroleum and Petroleum ProductsD4377 Test Method for
18、Water in Crude Oils by Potentiometric Karl Fischer TitrationD5002 Test Method for Density and Relative Density of Crude Oils by Digital Density AnalyzerD5191 Test Method for Vapor Pressure of Petroleum Products (Mini Method)D7042 Test Method for Dynamic Viscosity and Density of Liquids by Stabinger
19、Viscometer (and the Calculation of KinematicViscosity)3. Terminology3.1 Definitions:3.1.1 density, nmass per unit volume at a specified temperature.3.1.2 relative density, nthe ratio of the density of a material at a stated temperature to the density of water at a statedtemperature.3.2 Definitions o
20、f Terms Specific to This Standard:3.2.1 adjustment, vthe operation of bringing the instrument to a state of performance suitable for its use, by setting oradjusting the density meter constants.3.2.1.1 DiscussionOn some digital density analyzer instruments, an adjustment may be made rather than calib
21、rating the instrument. The adjustmentprocedure uses air and redistilled, freshly boiled reagent water (WarningHandling water at boiling or near boiling temperaturecan present a safety hazard. Wear appropriate personal protective equipment.) as standards to establish the linearity ofmeasurements over
22、 a range of operating temperatures.3.2.2 calibration, vset of operations that establishes the relationship between the reference density of standards and thecorresponding density reading of the instrument.4. Summary of Test Method4.1 A small volume (approximately 1 to 2 mL) volume, approximately 1 m
23、L to 2 mL, of liquid sample is introduced into anoscillating sample tube and the change in oscillating frequency caused by the change in the mass of the tube is used in conjunctionwith calibration data to determine the density, relative density, orAPI Gravity of the sample. Both manual and automated
24、 injectiontechniques are described.5. Significance and Use5.1 Density is a fundamental physical property that can be used in conjunction with other properties to characterize both thelight and heavy fractions of petroleum and petroleum products.5.2 Determination of the density or relative density of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40522015STANDARDTESTMETHODFORDENSITYRELATIVEDENSITYANDAPIGRAVITYOFLIQUIDSBYDIGITALDENSITYMETER 采用

链接地址:http://www.mydoc123.com/p-516160.html