《ASTM D4045-2004 Standard Test Method for Sulfur in Petroleum Products by Hydrogenolysis and Rateometric Colorimetry《利用加氢分解作用和速率测定比色法测试石油产品中的硫的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4045-2004 Standard Test Method for Sulfur in Petroleum Products by Hydrogenolysis and Rateometric Colorimetry《利用加氢分解作用和速率测定比色法测试石油产品中的硫的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4045 04An American National StandardStandard Test Method forSulfur in Petroleum Products by Hydrogenolysis andRateometric Colorimetry1This standard is issued under the fixed designation D 4045; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of sulfur inpetroleum products in th
3、e range from 0.02 to 10.00 mg/kg.1.2 This test method may be extended to higher concentra-tion by dilution.1.3 This test method is applicable to liquids whose boilingpoints are between 30 and 371C (86 and 700F). Materialsthat can be analyzed include naphtha, kerosine, alcohol, steamcondensate, vario
4、us distillates, jet fuel, benzene, and toluene.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4.1 Certain specifications for the recorder (see 5.5) areexcepted.1.5 This standard does not purport to address all of thesafe
5、ty concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent
6、 WaterD 6299 Practice for Applying Statistical Quality AssuranceTechniques to Evaluate Analytical Measurement SystemPerformance3. Summary of Test Method3.1 The sample is injected at a constant rate into a flowinghydrogen stream in a hydrogenolysis apparatus. The sampleand hydrogen are pyrolyzed at a
7、 temperature of 1300C, orabove, to convert sulfur compounds to hydrogen sulfide (H2S).Readout is by the rateometric detection of the colorimetricreaction of H2S with lead acetate. Condensable components areconverted to gaseous products, such as methane, during hydro-genolysis.4. Significance and Use
8、4.1 In many petroleum refining processes, low levels ofsulfur in feed stocks may poison expensive catalysts. This testmethod can be used to monitor the amount of sulfur in suchpetroleum fractions.4.2 This test method may also be used as a quality-controltool for sulfur determination in finished prod
9、ucts.5. Apparatus3,45.1 Pyrolysis FurnaceA furnace that can provide anadjustable temperature from 900 to 1400C in a 5-mm insidediameter or larger tube is required to pyrolyze the sample. Thefurnace entry temperature shall allow insertion of the hypoder-mic tip to a depth at which the temperature is
10、550C to providesample vaporization at the injection syringe tip. This tempera-ture shall be above the boiling point of the sample and of thesulfur compounds in the sample (see Fig. 1). The pyrolyzertube may be of quartz; however, the lifetime is limited above1250C. Ceramic may be used at any tempera
11、ture.5.2 Rateometric H2S Readout Hydrogenolysis productscontain H2S in proportion to sulfur in the sample. The H2Sismeasured by measuring rate of change of reflectance caused bydarkening when lead sulfide is formed. Rateometric electron-ics, adapted to provide a first derivative output, allows suffi
12、-cient sensitivity to measure below 0.1 mg/L (see Fig. 2).5.3 Hypodermic SyringeA hypodermic having a needlelong enough to reach the 550C zone is required. A side port isconvenient for vacuum filling and for flushing the syringe. A1This test method is under the jurisdiction of ASTM Committee D02 onP
13、etroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition approved May 1, 2004. Published June 2004. Originallyapproved in 1987. Last previous edition approved in 1999 as D 404599.2For referenced ASTM standards, visit the ASTM websi
14、te, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The apparatus described in 5.1-5.4 inclusive is similar in specification to theequipment available from Houston
15、Atlas, Inc., 22001 North Park Dr., Kingswood,TX 77339-3804. For further information see Drushel, H. V., “Trace SulfurDetermination Petroleum Fractions,” Analytical Chemistry, Vol 50, 1978, p. 76.4The sole source of supply of the apparatus known to the committee at this timeis Houston Atlas, Inc. If
16、you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee,1whichyou may attend.1*A Summary of Changes section appears at the end of this standard.Copyr
17、ight ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.100-L syringe is satisfactory for injection rates down to 3L/min and a 25-L syringe for lower rates. (WarningExercise caution as hypodermics can cause accidental injury.)5.4 Syringe Injection
18、 DriveThe drive shall provide uni-form, continuous sample injections. Variation in drive injectionrate caused by mechanical irregularities of gears will causenoise. The adjustable drive shall be capable of injection from 6L/min to 0.06 L/min over a 6-min interval.5.5 RecorderA chart recorder with 10
19、-V full scale and10 000-V input or greater and having a chart speed of 0.2 to 1in./min (approximately 0.5 to 3 cm/min) is required. Anattenuator can be used for more sensitive recorders. Newerinstruments that display the results are acceptable in lieu of achart recorder.5.6 ThermocoupleA thermocoupl
20、e suitable for use at 500to 1400C, 250-mm long with readout is required. Type K,116-in. (1.6-mm) diameter, Type 316 stainless steel sheath issuitable.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall r
21、eagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.5Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accur
22、acy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean Type II reagent gradewater conforming to Specification D 1193.6.3 Sensing TapeLead acetate impregnated paper of chro-matographic quality shall be used. (WarningLead is acumulative po
23、ison.)6.4 HydrogenAs no commercial grade of hydrogen has asulfur specification sufficiently low, each new source of supplymust be tested. A change in the zero base line of 5 % of fullscale from no flow to full flow indicates impure hydrogen.(WarningExtremely flammable gas under pressure. Hydro-gen i
24、s a flammable gas. Test all flow systems for leaks andpurge with inert gas before introducing hydrogen and afterremoving hydrogen. Keep all flow systems as small in volumeas practical and provide protective screening for containersother than sample flow lines. Dispose of exhaust gases in a5Reagent C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40452004STANDARDTESTMETHODFORSULFURINPETROLEUMPRODUCTSBYHYDROGENOLYSISANDRATEOMETRICCOLORIMETRY

链接地址:http://www.mydoc123.com/p-516133.html