ASTM D3934-1990(2007) Standard Test Method for Flash No Flash Test-Equilibrium Method by a Closed-Cup Apparatus《平衡闭杯法测定闪点 无闪点试验的标准试验方法》.pdf
《ASTM D3934-1990(2007) Standard Test Method for Flash No Flash Test-Equilibrium Method by a Closed-Cup Apparatus《平衡闭杯法测定闪点 无闪点试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3934-1990(2007) Standard Test Method for Flash No Flash Test-Equilibrium Method by a Closed-Cup Apparatus《平衡闭杯法测定闪点 无闪点试验的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3934 90 (Reapproved 2007)Standard Test Method forFlash/No Flash TestEquilibrium Method by a Closed-CupApparatus1This standard is issued under the fixed designation D 3934; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONASTM Flash Point Test Methods D56, D93, D 3278, and D 3941 are specified by governmentdepartments and
3、 agencies for determining whether liquids are flammable or combustible. Theseclassifications are used as the basis for regulating the handling and shipping of liquids.ISO/TC 35, Paints and Varnishes, and ISO/TC 28, Petroleum and Related Products, have issuedISO 1516 as a common standard, applicable
4、to paints, varnishes, petroleum, and related products. Thismethod is similar to ISO 1516 but uses standard ASTM cups and style and format. Test MethodsD 3278 and D 3828 operate on the equilibrium principle by using the Setaflash tester that has atemperature-control device.This test method does not d
5、etermine the finite flash point but whether or not flashing occurs at asingle specified temperature. The latter determination is made more accurate by ensuring that the testis carried out only when the material under test and the air/vapor mixture above it are in approximateequilibrium at the specif
6、ied temperature.1. Scope1.1 This test method covers the determination of whether aliquid complies with the closed-cup flash point requirements ingovernment regulations, or in specifications, or as agreedbetween the purchaser and the seller.1.2 This test method is limited to a temperature rangebetwee
7、n 0 and 110C (32 and 230F).1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard should be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under cont
8、rolled laboratory conditions andshould not be used to describe or appraise the fire hazard orfire risk of materials, products, or assemblies under actual fireconditions. However, results of this test may be used aselements of a fire risk assessment which takes into account allof the factors which ar
9、e pertinent to an assessment of the firehazard of a particular end use.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine th
10、e applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D56 Test Method for Flash Point by Tag Closed Cup TesterD93 Test Methods for Flash Point by Pensky-MartensClosed Cup TesterD 3278 Test Methods for Flash Point of Liquids by SmallScale Closed-Cup Appara
11、tusD 3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD 3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusE1 Specification for ASTM Liquid-in-Glass Thermometers2.2 ISO Standard:ISO 1516 Paints, varnishes, petroleum, and relatedproductsFlash/no-flash
12、 testClosed cup equilibriummethod33. Terminology3.1 Definitions:1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofASTM Subcommittee D01.22 on Flammability and Safety.Current edition approved
13、June 1, 2007. Published June 2007. Originallyapproved in 1982. Last previous edition approved in 2001 as D 3934 90 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, ref
14、er to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Stat
15、es.3.1.1 flash point, nthe lowest temperature corrected to apressure of 760 mm Hg (101.3 kPa) (1013 millibars) at whichapplication of an ignition source causes the vapor of thespecimen to ignite under specified conditions of test.4. Summary of Test Method4.1 A specimen in a closed cup of standard de
16、sign is heatedin a suitable liquid bath. After the specimen has been main-tained under equilibrium conditions for at least 10 min at thelowest allowable flash point temperature (within a permittedtolerance) of the specification or regulation, it is determinedwhether the specimen does or does not fla
17、sh.5. Significance and Use5.1 This test method ensures that before the flash test is runthe air/vapor space above the specimen has attained a satura-tion concentration of vapor by using standard closed cupsunder equilibrium conditions. The saturation concentration ofthe vapors will be attained at so
18、me temperature between that ofthe liquid and the cooler apparatus lid. However, this tempera-ture will be close to the temperature of the specimen after it hasbeen maintained at the specified temperature for at least a10-min period. This test method does not provide for thedetermination of the actua
19、l flash point but only whether aspecimen does or does not flash at a specified temperature.6. Apparatus6.1 Test Cups, specified in Test Methods D56 (Tag) andD93(Pensky-Martens). Remove the test cup assembly (includ-ing lid and specimen thermometer) from the Tag and Pensky-Martens apparatus to permit
20、 either to be used in a separatewater bath.NOTE 1If a stirrer is fitted to the test cup, it shall be operated duringthe heating period but must be stopped during the flashing determination.If a stirrer originally fitted to the test cup is removed, the aperture in thecover shall be securely plugged b
21、efore starting the test.6.2 Liquid Bath, capable of being adjusted to the requiredspecification temperature and of adequate heat capacity to meetthe requirements of the test. A bath fitted with a stirrer and anadjustable thermostat is convenient (see 9.2).NOTE 2The bath should be fitted with a cover
22、, especially when thespecified temperature is above 160F. At about this temperature theinerting effect of the water vapor may prevent or delay the flashing of theliquid under test.6.3 ThermometersStandard thermometers specified inTest Methods D56and D93. One thermometer shall be usedto measure the t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便